Main unit
15
Needle plate base assembly removal
1. Remove the 2 screws 1 to disconnect the cutter link assembly 1.
2. Remove the 2 screws 2, and then remove the needle plate base assembly.
16
Needle plate base disassembly
1. Remove the screws 1, 2, and then remove the rotary hook stopper.
2. Remove the screw 3, and then remove the movable knife and the movable
knife collar.
*Caution
• If there's a spacer under the movable knife collar, remove it
too.
3. Remove the screw 4, and then remove the fixed knife.
4. Remove the screw 5, and then remove the thread holding plate.
17
Picker bracket removal
1. Remove the retaining ring E2, and then remove the picker link.
2. Remove the 2 screws 1, and then remove the picker bracket final
assembly.
Start movie clip (CD-ROM version only)
2 - 12
Main parts
2
3
5
2
1
Retaining ring E2
1
1
1
4