CRC4 Mode
Enables the use of CRC4 for error checking. CRC (Cyclic Redundancy Check) is an error checking
control technique that uses a specific binary prime divisor that results in a unique remainder. It is
usually a 16- to 32-bit character. (Assignable only when using the PRI30 card.)
Value Range
Disable, Enable
Maintenance Console Location
2.7.16 [1-1] Slot—PRI Port (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Guide References
None
Line Coding
Selects the line coding type of the PRI PCM (Pulse Code Modulation) for the port.
Value Range
B8ZS, AMI
Maintenance Console Location
2.7.16 [1-1] Slot—PRI Port (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Guide References
None
Frame Sequence
Selects the type of frame sequence for the port.
Value Range
Extend Multi frame (ESF), 4-Frame Multi frame (F4), 12-Frame Multi frame (F12)