15. MR-E-
AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT

15.6.2 Alarms and warning list

When a fault occurs during operation, the corresponding alarm or warning is displayed. If any alarm or
warning has occurred, refer to Section 10.2.2 or 10.2.3 and take the appropriate action.
Set "
1" in parameter No. 49 to output the alarm code in ON/OFF status across the corresponding
pin and SG. Warnings (AL.E0 to AL.E9) have no alarm codes. Any alarm code is output at occurrence of
the corresponding alarm. In the normal status, the signals available before alarm code setting (CN1-12:
ZSP, CN1-11: RD, CN1-10: SA) are output.
The alarms marked
operations.
(Note 2) Alarm code
Display
CN1-10
pin
AL.10
0
AL.12
0
AL.13
0
AL.15
0
AL.16
1
AL.17
0
AL.19
0
AL.1A
1
AL.20
1
AL.24
0
AL.30
0
AL.31
0
AL.32
0
AL.33
0
AL.37
0
AL.45
1
AL.46
1
AL.50
1
AL.51
1
AL.8A
0
AL.8E
0
88888
0
AL.E0
AL.E1
AL.E6
AL.E9
Note: 1. Deactivate the alarm about 30 minutes of cooling time after removing the cause of occurrence.
2. 0: off
1: on
POINT
Configure up a circuit which will detect the trouble (ALM) signal and turn
off the servo-on (SON) signal at occurrence of an alarm.
in the alarm deactivation column can be deactivated by the corresponding
CN1-11
CN1-12
pin
pin
1
0
Undervoltage
0
0
Memory error 1
0
0
Clock error
0
0
Memory error 2
0
1
Encoder error 1
0
0
Board error
0
0
Memory error 3
0
1
Motor combination error
1
0
Encoder error 2
0
1
Main circuit error
1
0
Regenerative error
1
1
Overspeed
0
1
Overcurrent
1
0
Overvoltage
0
0
Parameter error
1
0
Main circuit device overheat
1
0
Servo motor overheat
1
0
Overload 1
1
0
Overload 2
0
0
Serial communication time-out error
0
0
Serial communication error
0
0
Watchdog
Excessive regenerative warning
Overload warning
Servo emergency stop warning
Undervoltage warning
Name
15 - 61
Alarm deactivation
Press
"SET" on
Power
current
OFF ON
alarm
screen.
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
Removing the cause of occurrence
deactivates the alarm
automatically.
Alarm
reset
(RES)
signal
(Note 1)
(Note 1)
(Note 1)