Sign In
Upload
Manuals
Brands
Viavi Manuals
Measuring Instruments
E4146QUAD
Viavi E4146QUAD Manuals
Manuals and User Guides for Viavi E4146QUAD. We have
1
Viavi E4146QUAD manual available for free PDF download: User Manual
Viavi E4146QUAD User Manual (128 pages)
Optical Time Domain Reflectometer For T-BERD®/MTS-2000, -4000 V2, -5800, SmartOTDR, CellAdvisor 5G and OneAdvisor-800 Platforms
Brand:
Viavi
| Category:
Measuring Instruments
| Size: 9.32 MB
Table of Contents
Table of Contents
7
About this Guide
13
Assumptions
14
Conventions
14
Purpose and Scope
14
Recycling Information
14
Technical Assistance
14
Chapter 1 Starting up
18
Unpacking the Device - Precautions
18
Precautions Relating to the OTDR Module Use
18
Connecting Fiber Optic Cable
18
Inspecting and Cleaning Connector End Faces
18
Optical Connector Types
19
Connecting Fiber Optic Cable to Test Port
20
Optical Connectors and Interchangeable Adapters
21
Interchangeable Adapters
21
Cleaning Universal Connectors
22
Chapter 2 SMART TEST Function
23
Principle of the Smart TEST
24
Selecting Smart TEST
24
Configuring the Unit for Smart TEST
25
Selecting the Configuration File
25
Modifying some Parameters before the Acquisition
26
Performing Acquisitions in Smart TEST Mode
28
Performing Acquisition in Real Time
28
Stopping the Real Time Acquisition
30
Performing an Acquisition in Smart TEST Mode
30
Actions on Trace During Acquisition
31
Results Display
33
Smartlink View
33
Showing the Detailed Information of One Event
35
Grouped Events
36
Trace View
37
Display of Events on the Trace
38
Results Table
38
Cursors
40
Zoom Function
41
Grouped Events
42
Changing the Type of an Event
43
Saving Results for Smart TEST Acquisitions
44
Chapter 3 Expert OTDR Function
47
Principle of the Expert OTDR
48
Selecting Expert OTDR
48
Configuring the Unit for Expert OTDR
49
Configuring the Acquisition Parameters
49
Configuring the Alarms Parameters
53
Configuring the Display Parameters
55
Section Attenuation
56
Section Length
56
Index of Refraction
56
Scatter Coefficient
58
Distance Unit
58
Results on Trace
58
Show Cursors
59
Configuring the Advanced Parameters
59
Front Connector Meas
59
Detection
59
Configuring the Link Description Parameters
61
Fiber ID
61
Fiber Number
62
Change Fiber Nbr
62
Cable ID
62
Direction
62
Location a
62
Location B
62
Configuring the Project Information Parameters
63
Technician ID
63
Job ID
63
Comment
63
Configuring the Report Parameters
63
File(S) Save in
64
Dir
65
Filenaming
65
File Content
65
Auto Store
66
Report as
66
Report Layout
66
Report Naming
66
Include Microscope Image
67
Configuration in Test Auto Mode
67
Saving OTDR Configuration in a File
68
Loading an Existing OTDR Configuration
69
Performing Acquisitions in Expert OTDR Mode
70
Performing Acquisition in Real Time
70
Stopping the Real Time Acquisition
72
Performing an Acquisition with Expert OTDR
72
Multi-Wavelength Acquisition
73
Actions on Trace During Acquisition
74
Results Display
75
Smartlink View
75
Trace View
77
Changing the Type of an Event
78
Advanced Functions
79
Automatic Measurement and Detection
79
Addition of Events
80
Representation of the Events
80
Hints on the Positioning of Markers
81
Deleting Events
81
Manual Measurements
81
Measurements of Slope
81
Measurement of ORL
82
Measurement of Reflectance
83
Splice Measurements
84
Memorization of the Position of Events
85
Overlay Trace Function
86
Overlaying Several Traces Stored in Memory
87
Display of Traces in Overlay
87
Adding Traces in Overlay
88
Removing a Trace
88
Reference Trace Function
89
Use of the Reference Trace Function in the Result Page
89
Using the Reference Trace Function in the Explorer
90
Saving the Trace(S) and Generating a Report
90
Saving Results and Creating a Report from Results Page
91
Opening a Report
93
Chapter 4 File Management
95
Description of the Explorer
96
Opening the File Explorer
96
Managing Tabs
96
File Signature
97
Buttons on the Right of the Screen
97
Storage Media
97
Directories and Files Editing Function
97
Saving and Loading Files
98
Saving Files from the Explorer
98
Loading Files and Displaying Traces
99
Simple Loading
99
Load with Configuration
99
Loading Several Traces in Overlay
100
Exporting Files
100
Explorer/Link Manager
100
Editing Function
102
Exporting a Directory in a Txt File
102
Generating Pdf Report(S)
103
Using the Merge Key, with the Txt/Pdf Files
104
Chapter 5 Technical Specifications
107
OTDR Modules for T-BERD/MTS 2000/4000 V2
108
Characteristics of Reflectometry Measurements
108
Manual Measurement
109
Typical Specifications
109
Ranges
111
Class of the Lasers of the OTDR Modules
112
OTDR Modules Measurement
113
OTDR Module Supply
113
Environment
113
Indoor/Outdoor
113
Temperature
113
Humidity
114
Pollution Degree
114
OTDR Technical Specifications for Smartotdr
114
OTDR Optical Interfaces
114
OTDR Optical Characteristics
114
Characteristics of Reflectometry Measurements
115
Typical Specifications
117
Characteristics of the Source (Standard) and Power Meter (Optional)
118
Source
118
Power Meter (through OTDR Port)
118
PON/XG-PON Power Meter (E118FA65PPM Version)
118
Chapter 6 Options and Accessories
119
Commercial References of Measurement Modules for T-BERD/MTS- 2000/4000 V2
120
OTDR Modules
120
Options
121
Commercial References of the Smartotdr
121
Advertisement
Advertisement
Related Products
Viavi E4123MM
Viavi E4126A-PC
Viavi E4126A-APC
Viavi E4106A-PC
Viavi E4106A-APC
Viavi E4136B-PC
Viavi E4136B-APC
Viavi E4138FB65-APC
Viavi E4118FB65-APC
Viavi E4126C-PC
Viavi Categories
Test Equipment
Measuring Instruments
Control Unit
Microscope
Server
More Viavi Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL