Sign In
Upload
Manuals
Brands
Thermo King Manuals
Refrigerator
SLXe-300
User Manuals: Thermo King SLXe-300 Refrigeration Unit
Manuals and User Guides for Thermo King SLXe-300 Refrigeration Unit. We have
2
Thermo King SLXe-300 Refrigeration Unit manuals available for free PDF download: Maintenance Manual, Manual
Thermo King SLXe-300 Maintenance Manual (342 pages)
Trailer Units
Brand:
Thermo King
| Category:
Refrigerator
| Size: 8.92 MB
Table of Contents
Table of Contents
3
Introduction
11
About this Manual
11
Units Covered
11
Other Reference Manuals
12
Safety Precautions
13
General Practices
13
Auto Start/Stop Controls
13
SL-400E, SLX, Slxe and Slxi with SMART REEFER 2/3 (SR-2/SR-3) CONTROLLER
14
Refrigerant
14
General Information
14
First Aid
14
Refrigerant Oil
14
Electrical
15
Microprocessor Service
15
Welding of Units or Truck Bodies
15
High Voltage
15
Low Voltage
15
Precautions
16
First Aid
16
Unit Decals
16
Specifications
19
Engine
20
Drive System
22
Refrigeration System
23
R-404A/R-452A
23
Heat and Defrost System
24
Controller
25
Electrical Control System
26
Electrical Components
27
Evaporator Fan Motors
27
Electric Standby
29
Electric Drive Motor
29
Standby Power Requirements
29
Remote Evaporator Specifications
29
Maintenance Inspection Schedule
31
All SL and Sle and Spectrum Models Host Unit
32
Remote Evaporators: ECT, ELT, EW, SPECTRUM and TLE
35
All SLX, Slxe Range and Spectrum Models Host Unit
36
SLX, Slxe SPECTRUM
39
All Slxi-100, Slxi-200, Slxi-300, Slxi-400, Slxi SPECTRUM Range
40
Unit Description
45
Single Temperature Systems
46
Multi-Temperature Systems
46
Unit Features
46
Compressors
46
Engines
46
Controllers
46
Service Test Mode (Standard on TG-VI, Μp-IV, Μp-V, Μp-VI, SR-2 and SR-3 Controllers)
47
Electric Standby Motors
47
Refrigeration Modulation Option
47
Discharge Air Modulation Control
47
Electronic Throttling Valve
47
Data Logging Option (Μp-IV, Μp-V, Μp-VI, SR-2 and SR-3 Controllers)
48
Sleep Mode Option (Option on Μp-IV and Μp-V Controllers, Standard on Μp-VI, SR-2 and SR-3 Controllers)
48
Tracking Option (Μp-IV, Μp-V, Μp-V, SR-2 and SR-3 Controllers)
48
CYCLE-SENTRY (Start/Stop) Control Option
48
Economy Mode Control Option
49
Optiset™ Option
50
Data Acquisition System (DAS) Option
50
Remote Control Options (SR-3, SR-2, TG-V, Μp-IV Multi-Temp, Μp-V and Μp-VI Controllers)
50
Sequence of Operation
50
100, SL-100E, SL-200 and SL-200E (TG-VI Controller)
54
Μp-IV or Μp-V Controller)
55
(Μp-IV or Μp-V Controller)
55
400, Sle-400, Slx/Slxe/Slxi and Slx/Slxe/Slxi Spectrum
57
Controller)
57
Thermo King SR Basic Operational Sequence Diesel Mode
60
Operation
60
Thermo King SR Basic Operational Sequence Electric Standby Mode
62
Operation
62
Multi-Temp SR-2/SR-3 Controller)
64
Engine Compartment Components
70
Remote Evaporator Unit Description
71
Unit Operation
72
Defrost
72
Operating Modes
72
Unit Features
72
Protection Devices
73
TG-VI, Μp-IV, Μp-V, Μp-VI and SR-2/SR-3 Control Systems
73
Spectrum Remote Evaporator Unit
73
Serial Number Locations
73
Unit Nameplate
73
TLE and SPECTRUM Remote Evaporator Nameplate
73
Engine Nameplate
73
Compressor Nameplate
73
Electric Motor Nameplate
73
Operating Instructions
75
Unit Controls
76
Unit Control Panel
76
SMART REEFER 2/3 Multi-Temp (SR-2/SR-3 MT) Control System
80
HMI Control Panel
81
Display
82
Control Panel Keys (Single or Multi-Temp SR-2/SR-3)
83
Unit Operation (Single or Multi-Temp SR-2/SR-3)
84
Manual Pretrip Inspection (before Starting Unit)
84
Turning Unit on (Single or Multi-Temp SR-2/SR-3)
85
Turning Unit off (Single or Multi-Temp SR-2/SR-3)
86
Standard Display
87
Operating the Unit in Single Zone Control Mode
88
Standard Display Variations
89
Alarm Display
89
Temperature Watch Display
90
Other Unit Controls
90
Unit Instruments
92
Unit Protection Devices
94
Unit Operation
94
Visual Pre-Trip Inspection
94
Selection of Operating Modes on CYCLE-SENTRY Equipped Units
96
Starting Units on Continuous Run, Diesel Operation
97
Starting Units on CYCLE-SENTRY, Diesel Operation
97
Starting Model 50 Units on Electric Standby Power
98
After Start Inspection
98
Loading Procedure
99
Post Load Procedure
100
Post Trip Inspection
100
Controller Operation
101
Thermoguard Multi-Temp MT Μp-IV and Μp-V Controllers
102
Entering Setpoint Temperature
103
Selecting CYCLE-SENTRY or Continuous Run Mode (Multi-Temp MT Μp-IV and Μp-V ONLY)
103
Initiating Manual Defrost
103
Viewing Information (Display) Screens
104
Checking the Software Version
105
Displaying and Clearing Alarm Codes
105
Unit Pre-Trip Test
106
Thermoguard TG-VI Controller
107
Entering Setpoint Temperature
108
Selecting CYCLE-SENTRY or Continuous Run Mode
108
Initiating Manual Defrost
109
Checking the Software Version
109
Displaying and Clearing Alarm Codes
109
Viewing Information (Display) Screens
109
Unit Self-Check Test
110
Multi-Temp Remote Control Panel
111
Displaying Operating Data
112
Entering Setpoint Temperature
112
Thermoguard Μp-VI Controller
113
Entering Setpoint Temperature
114
Selecting CYCLE-SENTRY or Continuous Run Mode
114
Initiating Manual Defrost
114
Selecting Economy Mode - Revision 4000 and 4010 Software Only
115
Viewing Information (Display) Screens
115
Checking the Software Version
117
Displaying and Clearing Alarm Codes
118
Unit Pre-Trip Test
118
Entering a Start of Trip in the Data Logger
119
SR-2/SR-3 Controller
120
HMI Control Panel
120
Changing the Setpoint
121
Selecting CYCLE-SENTRY or Continuous Mode
121
Initiating a Manual Defrost Cycle
121
Terminating a Defrost Cycle
121
Viewing Gauge Readings
121
Viewing Sensor Readings
122
Navigating the Operator Menu
122
Alarm Codes for Μp-IV, Multi-Temp Μp-IV, Μp-V, Μp-VI, TG-VI , SR-2 and SR-3 Controllers
125
Telematic Status Alerts for TK Bluebox
127
Electrical Maintenance
129
Alternator (Australian Bosch)
130
Charging System Diagnostic Procedures
130
Field Current Test
133
Alternator Removal
134
Alternator Disassembly
134
Inspecting and Diagnosing Components
136
Alternator Assembly
138
Alternator Installation
140
Alternator (Thermo King)
141
Alternator Removal
143
Battery
143
Unit Wiring
144
12 VDC CHARGING SYSTEM
144
Fuse Link
144
Fuses
145
Fuses (Units with TG-VI, MT Μp-IV, Μp-V, Μp-VI, SR-2 or SR-3)
145
Relay Board
146
TG-VI, MT Μp-IV, Μp-V, Μp-VI, SR-2 or SR-3 Controller
147
Air Heater
148
Low Oil Level Switch
149
Switch Test
149
Switch Removal and Installation
149
Bench Test
149
High Water Temperature Switch
150
Switch Test
150
Condenser and Evaporator Fan Rotation (Electric Standby Operation)
150
Evaporator Heaters
151
SL, SLE, SLX, Slxe, Slxi
151
AC Components (Model 50 Units)
151
Electrical Contacts
151
Overload Relay
151
Phase Indicator
151
Phase Correction Option
152
Diagnosing the Phase Correction System
152
Defrost System
154
Defrost Cycle
154
Defrost Cycle Checkout Procedure
154
Defrost Components
155
Engine Maintenance
157
Engine Lubrication System
158
Engine Oil Change
158
Oil Filter Change
158
Crankcase Breather
158
TK 482, TK 486, TK 486V Engines
158
Engine Air Cleaner
159
Dry Type
159
Cyclonic Air Cleaner
161
Engine Cooling System
162
Antifreeze Maintenance Procedure
162
ELC (Extended Life Coolant)
165
Checking the Antifreeze
166
Changing the Antifreeze
166
Bleeding Air from the Cooling System
166
Engine Thermostat
167
Engine Fuel System
168
TK 482, TK 486 and TK 486V
169
Maintenance
170
Bleeding the Fuel System
170
Water in the Fuel System
171
Single Element Fuel Filter/Water Separator Replacement
172
TK 482, TK 486 and TK 486V Engines
173
Integral Fuel Solenoid - TK 482, TK 486 and TK 486V
173
Diagnosing the Integral Fuel Solenoid System
174
Fuel Solenoid Replacement
178
Injection Pump Service and Timing
178
Injection Pump Installation & Timing
178
TK 482, TK 486 and TK 486V Engines
180
TK 482, TK 486 and TK 486V Engines
185
Belt Tension Adjustment and Belt Replacement
187
SL Belt Adjustments
188
Sle, SLX, Slxe, Slxi and Spectrum Belt Adjustments
192
Blower Belts - Upper and Lower Poly-V Groove Belt Replacement on SL Units and Upper Belt Only on SLX, Slxe, Slxi
193
SLX, Slxe, Slxi Belt Replacement
195
SLX, Slxe Upper Belt Replacement
196
Slxe (from October 2016) and Slxi Upper Belt Replacement
198
Compressor Drive Belt Replacement and Adjustment (Model 50)
201
Lower (Engine to Electric Motor or Cross Shaft) Belt (SLX ONLY)
203
SLX Retrofit Clutch Tensioner
204
Clutch Drive Tensioning Schematic Slxe and Slxi
206
Clutch Maintenance
209
SL and Sle Models
211
10 Refrigeration Maintenance
213
Service Tools
214
Leak Detection
214
Compressor Oil
214
Vacuum Pumps
214
Gauge Manifold Sets
214
System Clean-Up
214
Refrigerant Recovery
214
Refrigeration Maintenance Procedures
215
Additional Information Low Side Pump down for TCI and SPECTRUM Models
215
Compressor Oil Acid Test
216
Checking Compressor Oil
216
Refrigerant Charge
217
Checking Refrigerant Charge with an Empty Trailer
217
Checking Refrigerant Charge with a Loaded Trailer
217
Refrigerant Overcharge Check
218
Moisture Indicating Sight Glass (Where Fitted)
219
Moisture Indicating Sight Glass
219
SLX, Slxe, Slxi Spectrum Charging Procedures
220
Micro-Channel Condenser and Auxiliary Receiver Design
220
Charging Procedure for SLX SPECTRUM Categories
220
SLX, Slxe, Slxi SPECTRUM Charging Procedure
221
Refrigerant Leaks
222
Evacuating and Charging Smart Reefer Multi-Temp Systems
222
Set-Up Unit
222
System Evacuation
222
Evacuation Is Important and Critical to System Performance
222
Set-Up and Test Evacuation Equipment
225
Unit Evacuation
227
Unit Charging
228
Remove Evacuation Hoses
230
High Pressure Cutout
230
Head Pressure Control Switch (SL TCI and SL Spectrum)
230
Three-Way Valve Condenser Pressure Bypass Check Valve
230
Modulation Valve
231
Electronic Throttling Valve (ETV)
232
Hot Gas Bypass Valve
232
Spectrum Multi-Temperature Refrigeration Components
233
Host Unit Components
233
Zone Refrigeration Control Components
233
Refrigeration Service Operations
235
Refrigeration System Components
236
Low Side Pump down
236
Compressor
236
High Pressure Cutout Switch or High Pressure Cycle (Control) Switch
237
Condenser Coil
238
Discharge Vibrasorber
238
Suction Vibrasorber
238
Receiver Tank
240
Bypass Check Valve
240
High Pressure Relief Valve
241
Dehydrator (Filter-Drier)
241
Expansion Valve Assembly
241
Evaporator Coil
242
Heat Exchanger
243
Accumulator
243
Pilot Solenoid
244
Modulation Valve (SL and SLE Only)
244
Hot Gas Bypass Solenoid Valve
244
Modulation Valve
244
Throttling Valve (Non-ETV Units)
245
Three-Way Valve Condenser Pressure Bypass Check Valve Repair
248
Three-Way Valve Repair
249
External Compressor Oil Filter - X214, X426 or X430 Compressor
251
Electronic Throttling Valve (ETV)
252
Multi-Temperature System Components
256
Discharge Pressure Sensor
256
Liquid Line Solenoid Valve (LLS, LLS2, LLS3, RLLS or CLLS) or Suction Line Solenoid Valve (SLS, SLS2, SLS3, RSLS or CSLS)
256
Condenser Inlet Solenoid Valve (CIS) or Hot Gas Solenoid Valve (HGS, HGS2, HGS3, RHGS, HGBP or CHGS)
257
Suction Line Check Valve (SLCV, SLCV2, SLCV3, RSLCV or CSLCV), Purge Check Valve (PCV) or Liquid Return Check Valve (LRCV, LRCV2, LRCV3, RLRCV or CLRCV)
257
Condenser Inlet Solenoid Valve (CIS) or Hot Gas Solenoid Valve (HGS, HGS2, HGS3
257
Receiver Tank Pressure Solenoid Valve (RTPS)
258
Purge Valve (PV)
258
12 Structural Maintenance
259
Unit and Engine Mounting Bolts
260
Unit Inspection
261
Defrost Drains
261
Condenser, Evaporator and Radiator Coils
261
Micro-Channel Coil Cleaning Recommendations
261
Unit Installation
263
SL and Sle Top Center Nut
264
Access to Mounting Holes SLX, Slxe, Slxi
265
Access to Mounting Holes Slx/Slxe/Slxi
265
Defrost Damper
266
Damper Door Motor with Current Sensing Blade Position Control
280
And Late Model SL Units)
280
Damper Door Motor with Current Sensing Blade Position Control (Slxi, Slxe, SLX, Sle and Late Model SL Units)
280
Fan Shaft Assembly
285
SL and Sle
285
SL and Sle
294
Slxi, Slxe, SLX Fan Shaft Assembly
299
Lower Blower Assembly Slxi, Slxe, SLX
300
Jackshaft/ Cross Shaft Assembly
301
Sle and SPECTRUM
303
Slxi, Slxe, SLX Cross Shaft Assembly
307
Remote Evaporator Unit
308
Unit Inspection
308
Defrost Drains
308
Evaporator Coil
308
13 Mechanical Diagnosis
309
TK 482, TK 486 and TK 486V Engines
310
Refrigeration System Diagnosis
317
All Models Except TCI and SPECTRUM
318
TCI and SPECTRUM Models
320
Remote Evaporator System Diagnosis
321
Single Temperature Refrigeration System Diagrams
323
Sl/Sle 100, 200 and SLX, Slxe, Slxi 100, 200 WITHOUT MODULATION
324
Cooling Cycle
324
Heat and Defrost Cycles
325
Sle 200 and 300
326
Cooling Cycle with Modulation
326
Heat and Defrost Cycles with Modulation
327
SL-400 and SL-400E
328
Cooling Cycle with Modulation
328
Heat and Defrost Cycles with Modulation
329
SLX 200 PPP, 300, 400, Slxe 300, 400 and SLXI 300, 400
330
Cooling Cycle with Modulation
330
Heat and Defrost Cycles with Modulation
331
Multi-Temperature Refrigeration System Diagrams
333
Sl Tci, or Spectrum
334
Zone 1* on Cool and Zone 2** on Cool
334
Zone 1* on Cool and Zone 2** on Heat
335
Zone 1* on Cool, Zone 2** on Cool and Zone 3*** on Cool
336
Zone 1* on Cool, Zone 2** on Cool and Zone 3*** on Heat
337
SLX, Slxe, SLXI Spectrum
338
Zone 1* on Cool, Zone 2** on Heat
338
Wiring Diagrams and Wiring Schematics
341
Advertisement
Thermo King SLXe-300 Manual (282 pages)
Brand:
Thermo King
| Category:
Refrigerator
| Size: 3.94 MB
Table of Contents
English
5
Table of Contents
5
Sistema DI Controllo Thermo King Smart REEFER
5
Introduction
6
General Information
6
Thermo Assistance
6
First Aid and Safety
7
Refrigerant
7
Refrigerant Oil
7
Refrigerant Information
7
Electrical Hazard
8
Auto Start/Stop Operation
8
Safety Precautions
8
Unit Description
9
General Information
9
Thermo King Smart REEFER 3 (SR-3)
10
Controller
10
CYCLE-SENTRY Start/Stop Controls
12
Defrost
12
Modulation
12
Care and Maintenance
13
Pre-Trip Inspection
13
Loading
14
Inspection and Service Schedules
16
Warranty
17
Specifications
19
Electrical Control System
20
Electric Motor (Model 50)
21
(200V Option Available)
21
Standby Power Requirements
21
Safety Decals and Serial Numbers
22
Safety Decals
22
Serial Number Decals
22
Français
25
Informations Générales
26
Introduction
26
Thermo Assistance
26
Fluide Frigorigène
28
Huile de Réfrigération
28
Informations Relatives au Fluide Frigorigène
28
Premiers Secours et Sécurité
28
Consignes de Sécurité
29
Fonctionnement en Mode Marche/Arrêt Automatique
29
Risques D'électrocution
29
Description du Groupe
31
Informations Générales
31
Contrôleur Smart REEFER 3 (SR-3) Thermo King
32
Commandes Marche/Arrêt CYCLE-SENTRY
34
Dégivrage
35
Modulation
35
Inspection Avant-Trajet
36
Soin et Entretien
36
Chargement
37
Inspection et Programmes D'entretien
39
Garantie
40
Caractéristiques Techniques
42
Système de Commandes Électriques
43
Besoins en Alimentation Électrique
44
Moteur Électrique (MODÈLE 50) (200 V Disponible en Option)
44
Autocollants de Sécurité
45
Autocollants de Sécurité et Numéros de Série
45
Autocollants des Numéros de Série
45
Italiano
49
Indice
49
Informazioni Generali
50
Introduzione
50
Thermo Assistance
50
Informazioni Relative al Refrigerante
52
Olio Refrigerante
52
Pronto Soccorso Emisure DI Sicurezza
52
Refrigerante
52
Funzionamento con Avviamento/Arresto Automatico
53
Misure DI Sicurezza
53
Pericolo DI Scariche Elettriche
53
Descrizione Dell'unità
55
Informazioni Generali
55
Comandi DI Avviamento/Arresto CYCLE-SENTRY
58
Modulazione
59
Sbrinamento
59
Cura E Manutenzione
60
Verifiche Prima Della Partenza
60
Caricamento
61
Programmi DI Ispezione E DI Assistenza
64
Garanzia
65
Caratteristiche Tecniche
67
Sistema DI Controllo Elettrico
68
(Opzione 200 V Disponibile)
69
Motore Elettrico (Modello 50)
69
Requisiti Per L'alimentazione Elettrica DI Riserva
69
Decalcomanie DI Sicurezza
70
Decalcomanie DI Sicurezza E Numeri DI Serie
70
Decalcomanie Numero DI Serie
70
Deutsch
73
Inhaltsverzeichnis
73
Allgemeines
74
Einleitung
74
Thermo Assistance
74
Erste Hilfe und Sicherheit
76
Kältemittel
76
Kältemittelinformationen
76
Kältemittelöl
76
Auto-Start/Stopp-Betrieb
77
Gefahren durch Elektrizität
77
Sicherheitshinweise
77
Allgemeines
79
Gerätebeschreibung
79
Thermo King Smart REEFER 3 (SR-3)-Regler
80
CYCLE-SENTRY-Start/Stopp-Regler
82
Abtaubetrieb
83
Modulation
83
Inspektion vor Fahrtbeginn
84
Pflege und Wartung
84
Ladeverfahren
85
Inspektions- und Wartungspläne
87
Garantie
88
Technische Daten
90
Elektrisches Reglersystem
91
(200 V Optional Verfügbar)
92
Elektromotor (Modell 50)
92
Voraussetzungen für Netzbetrieb
92
Seriennummernaufkleber
93
Sicherheitsaufkleber
93
Sicherheitsaufkleber und Seriennummern
93
Español
97
Índice
97
Información General
98
Introducción
98
Thermo Assistance
98
Aceite Refrigerante
100
Información sobre el Refrigerante
100
Primeros Auxiliosy Seguridad
100
Refrigerante
100
Funcionamiento de Arranque/Parada Automático
101
Peligro Eléctrico
101
Precauciones de Seguridad
101
Descripción de la Unidad
103
Información General
103
Controlador Smart REEFER 3 (SR-3) de Thermo King
104
Controles de Arranque/Parada de CYCLE-SENTRY
106
Descarche
107
Modulación
107
Cuidados Ymantenimiento
108
Inspección Antes del Viaje
108
Procedimiento de Carga
109
Programas de Inspección y Mantenimiento
111
Garantía
112
Características Técnicas
114
Sistema de Control Eléctrico
115
(Opción de 200 V Disponible)
116
Motor Eléctrico (Modelo 50)
116
Requisitos del Sistema Eléctrico
116
Adhesivos de Los Números de Serie
117
Adhesivos de Seguridad
117
Adhesivos de Seguridad y Números de Serie
117
Polski
121
Spis TreśCI
121
Informacje Ogólne
122
Thermo Assistance
122
Wprowadzenie
122
Czynnik Chłodniczy
124
Informacje Dotyczące Czynnika Chłodniczego
124
Olej Chłodniczy
124
Pierwsza Pomoci Bezpieczeństwo
124
Automatyczne Uruchamianie/Zatrzymywanie
125
Niebezpieczeństwo Porażenia Prądem
125
Środki OstrożnośCI
125
Informacje Ogólne
127
Opis Agregatu
127
Sterownik Smart REEFER 3 (SR-3) Firmy Thermo King
128
Elementy Sterowania Do Uruchamiania/Zatrzymywania Trybu Automatycznego Włączania I Wyłączania (CYCLE-SENTRY)
130
Modulacja
131
Odszranianie
131
Konserwacja
132
PrzegląD Przed Wyruszeniemw Trasę
132
Załadunek
133
Harmonogram Kontroli I Serwisu
135
Gwarancja
136
Dane Techniczne
138
Elektryczny Układ Sterowania
139
INHOUDSOPGAVE Inhoudsopgave
139
(Dostępna Opcja 200 V)
140
Silnik Elektryczny (Model 50)
140
Wymagania Dot. Zasilania W Trybie Podtrzymania
140
Plakietki Ostrzegawcze
141
Plakietki Ostrzegawcze I Numery Seryjne
141
Plakietki Z Numerami Seryjnymi
141
Dutch
145
Algemene Informatie
146
Inleiding
146
Thermo Assistance
146
EHBO en Veiligheid
148
Informatie over Koudemiddel
148
Koudemiddel
148
Koudemiddelolie
148
Automatisch Starten en Stoppen
149
Elektrisch Gevaar
149
Veiligheidsmaatregelen
149
Algemene Informatie
151
Beschrijving Van de Unit
151
Thermo King Smart REEFER 3 (SR-3) Controller
152
CYCLE-SENTRY Start/Stop-Bediening
154
Ontdooien
154
Modulatie
155
Inspectie Vóór de Reis
156
Verzorging en Onderhoud
156
Laden
157
Controle- en Onderhoudsschema's
159
Garantie
160
Specificaties
162
Elektrisch Regelsysteem
163
(200V Optioneel Verkrijgbaar)
164
Elektromotor (Model 50)
164
Vereisten Elektrische Hulpmotor
164
Plaatjes Met Serienummer
165
Veiligheidsaanduidingen
165
Veiligheidsaanduidingen en Serienummers
165
Türkçe
169
İçİndeki̇ler
169
Genel BİLGİLER
170
Gi̇ri̇ş
170
Thermo Assistance
170
Soğutucu Akışkan
172
Soğutucu Akışkan BİLGİLERİ
172
Soğutucu Yağı
172
İlk YardıM Ve GÜVENLİK
172
Elektriksel Tehlike
173
Güvenli̇k Önlemleri̇
173
Otomatik Başlatma/Durdurma İŞLEMİ
173
Genel BİLGİLER
174
ÜNİTE TanıMı
174
Thermo King Smart REEFER 3 (SR-3) Kontrol ÜNİTESİ
175
Buz Çözme
177
CYCLE-SENTRY Başlatma/Durdurma
177
Kontrolleri̇
177
Modülasyon
177
BakıM
178
Yolculuk ÖNCESİ Denetleme
178
Yükleme
179
DENETİM VE SERVİS Planları
181
Garanti̇
182
Tekni̇k Özelli̇kler
184
Elektri̇k Kontrol Si̇stemi̇
185
(200V SEÇENEĞİ Mevcut)
186
ELEKTRİK Motoru (Model 50)
186
Yedek Güç GEREKSİNİMLERİ
186
GÜVENLİK Çıkartmaları
187
GÜVENLİK Çıkartmaları Ve SERİ Numaraları
187
SERİ Numarası Çıkartmaları
187
Português
191
Sumário
191
Informação Geral
192
Introdução
192
Thermo Assistance
192
Informação sobre O Líquido Refrigerante
194
Primeiros Socorros Esegurança
194
Refrigerante
194
Óleo de Refrigeração
194
Operação Automática de Arranque/Paragem
195
Perigo Elétrico
195
Precauções de Segurança
195
Descrição da Unidade
197
Informação Geral
197
Controlador Thermo King Smart REEFER 3 (SR-3)
198
Controlos de Arranque/Paragem CYCLE-SENTRY
200
Descongelação
201
Modulação
201
Cuidados E Manutenção
202
Inspeção Antes da Viagem
202
Carregamento
203
Programas de Inspeção E Assistência
205
Garantia
206
Especificações
208
Sistema de Controlo Eléctrico
209
(Opção 200 V Disponível)
210
Motor Elétrico (Modelo 50)
210
Requisitos para a Alimentação Do Funcionamento Elétrico
210
Autocolantes de Números de Série
211
Autocolantes de Segurança
211
Autocolantes de Segurança E Números de Série
211
Dansk
215
Indholdsfortegnelse
215
Generel Information
216
Introduktion
216
Thermo Assistance
216
Førstehjælp Og Sikkerhed
218
Information Om Kølemiddel
218
Kølemiddel
218
Kølemiddelolie
218
Automatisk Start/Stop
219
Elektrisk Fare
219
Sikkerhedsforanstaltninger
219
Beskrivelse Af Anlægget
220
Generel Information
220
Thermo King Smart REEFER 3 (SR-3) Controller
221
Afrimning
223
CYCLE-SENTRY Start/Stop-Styringer
223
Modulation
223
Prætripinspektion
224
Vedligeholdelse
224
Lastning
225
Planlagt Service Og Eftersyn
227
Garanti
228
Specifikationer
230
Elektrisk Styresystem
231
Elmotor (Model 50) (200 V Fås Som Ekstraudstyr)
232
Strømkrav Ved Standby
232
Serienummerskilte
233
Sikkerhedsskilte
233
Sikkerhedsskilte Og Serienumre
233
Svenska
237
Innehållsförteckning
237
Allmän Information
238
Inledning
238
Thermo Assistance
238
Första Hjälpen Och Säkerhet
239
Information Om Köldmedium
239
Köldmedieolja
239
Köldmedium
239
Automatisk Start Och Avstängning
240
Elektrisk Fara
240
Säkerhetsföreskrifter
240
Allmän Information
241
Beskrivning Av Enheterna
241
Thermo King Smart REEFER 3-Styrenhet (SR-3)
242
Avfrostning
244
Modulering
244
Start Och Avstängning Med CYCLE-SENTRY-Styrning
244
Förkontroll
245
Skötsel Och Underhåll
245
Lastning
246
Inspektions- Och Servicescheman
248
Garanti
249
Specifikationer
251
Elektriskt Styrsystem
252
(200 V Tillgänglig Som Alternativ)
253
Elmotor (Modell 50)
253
Strömkrav VID Standby-Drift
253
Serienummermärken
254
Säkerhetsmärken
254
Säkerhetsmärken Och Serienummer
254
Русский
257
Содержание
257
Введение
258
Общие Сведения
258
Служба Thermo Assistance
258
И Техника Безопасности
260
Информация О Хладагентах
260
Охлаждающее Масло
260
Первая Помощь
260
Хладагент
260
Меры Безопасности
261
Опасность Поражения Электрическим Током
261
Работа В Режиме Автоматического Пускаи Остановки
261
Общие Сведения
263
Описание Установки
263
Интеллектуальный Контроллер Smart REEFER 3 (SR-3) Компании Thermo King
264
Элементы Управления Пуском И Остановом CYCLE-SENTRY
266
Модуляция
267
Оттайка
267
Предрейсовый Осмотр
268
Уход И Техническое Обслуживание
268
Погрузка
269
Графики Осмотров И Обслуживания
271
Гарантия
272
Технические Характеристики
274
Электрическая Система Управления
275
(Возможна Опция 200 В)
276
Требования К Резервному Электропитанию
276
Электродвигатель (Модель 50)
276
Предупредительные Таблички
277
Предупредительные Таблички И Таблички С Серийными Номерами
277
Таблички С Серийными Номерами
277
Açiklama
279
Declaración
279
Declaration
279
Declaração
279
Deklaracja
279
Dichiarazione
279
Déclaration
279
Erklärung
279
Erklæring
279
Verklaring
279
Advertisement
Related Products
Thermo King SLXe-100
Thermo King SLXe-200
Thermo King SLXe-400
Thermo King SLXe SPECTRUM
Thermo King SLXe Whisper
Thermo King SLXe SPECTRUM Whisper Pro
Thermo King SLX-100
Thermo King SLX-200
Thermo King SLX Ferry
Thermo King SLXe Series
Thermo King Categories
Refrigerator
Automobile Accessories
Air Conditioner
Portable Generator
Heat Pump
More Thermo King Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL