Sign In
Upload
Manuals
Brands
Tektronix Manuals
Test Equipment
MDO4054-3
Tektronix MDO4054-3 Manuals
Manuals and User Guides for Tektronix MDO4054-3. We have
2
Tektronix MDO4054-3 manuals available for free PDF download: User Manual, Instructions Manual
Tektronix MDO4054-3 User Manual (222 pages)
MDO4000 Series Mixed Domain Oscilloscopes
Brand:
Tektronix
| Category:
Test Equipment
| Size: 4.54 MB
Table of Contents
Table of Contents
8
General Safety Summary
12
Compliance Information
14
EMC Compliance
14
Safety Compliance
15
Pollution Degree
16
Overvoltage Category
16
Environmental Considerations
16
Preface
18
Key Features
18
Conventions Used in this Manual
18
Installation
20
Before Installation
20
Operating Considerations
24
Operating Positions
26
Connecting Probes
27
Securing the Oscilloscope
28
Powering on the Oscilloscope
29
Powering off the Oscilloscope
30
Functional Check
30
Compensating a TPP0500 or TPP1000 Passive Voltage Probe
31
Compensating a Non-TPP0500 or Non-TPP1000 Passive Voltage Probe
33
Application Module Free Trial
34
Installing an Application Module
34
Changing the Language of the User Interface or Keyboard
35
Changing the Date and Time
36
Signal Path Compensation
38
Upgrading Firmware
40
Connecting Your Oscilloscope to a Computer
43
Connecting a USB Keyboard to Your Oscilloscope
51
Get Acquainted with the Instrument
52
Front-Panel Menus and Controls
52
Using the Menu System
53
Front-Panel Connectors
66
Side-Panel Connector
66
Rear-Panel Connectors
67
Acquire the Signal
69
Setting up Analog Channels
69
Using the Default Setup
72
Using Autoset
73
Acquisition Concepts
74
Waveform Record
75
How the Analog Acquisition Modes Work
76
Changing the Acquisition Mode, Record Length, and Delay Time
76
Using Roll Mode
78
Setting up a Serial or Parallel Bus
79
Setting up Digital Channels
92
When and Why to Turn on Magnivu
94
Using Magnivu
94
Setting up the RF Inputs
95
Trigger Setup
99
Triggering Concepts
99
Trigger Holdoff
100
Trigger Coupling
100
Slope and Level
101
Choosing a Trigger Type
102
Selecting Triggers
103
Triggering on Buses
105
Checking Trigger Settings
109
Using Sequence Trigger (a (Main) and B (Delayed))
110
Starting and Stopping an Acquisition
112
Triggering on the RF Input
112
Display Waveform or Trace Data
115
Adding and Removing a Waveform
115
Setting the Display Style and Persistence
115
Setting the Graticule Style
117
Setting the Lcd Backlight
118
Setting Waveform Intensity
119
Scaling and Positioning a Waveform
120
Setting Input Parameters
121
Positioning and Labeling Bus Signals
125
Positioning, Scaling, and Grouping Digital Channels
125
Viewing Digital Channels
127
Annotating the Screen
127
Viewing the Trigger Frequency
128
Displaying the Frequency Domain Menu
129
Analyze Waveform or Trace Data
136
Using Markers in the Frequency Domain
136
Taking Automatic Measurements in the Frequency Domain
139
Taking Automatic Measurements in the Time Domain
140
Selecting Automatic Measurements in the Time Domain
141
Customizing an Automatic Measurement in the Time Domain
145
Taking Manual Measurements with Cursors
148
Setting up a Histogram
152
Using Math Waveforms
155
Using FFT
156
Using Advanced Math
159
Using Spectrum Math
160
Using Reference Waveforms and Traces
161
Using Wave Inspector to Manage Long Record Length Waveforms
163
Auto-Magnify
168
Time-Correlated Multi-Domain Display
169
Limit and Mask Testing
173
Analyzing Power
179
Save and Recall Information
180
Saving a Screen Image
182
Saving and Recalling Waveform and Trace Data
183
Saving and Recalling Setups
186
Saving with One Button Push
188
Managing Drives, Directories, and Files
189
Mounting a Network Drive
189
Printing a Hard Copy
190
Erasing Oscilloscope Memory
196
Using Application Modules
198
Appendix A: MDO4000 Specifications
199
Appendix B: TPP0500 and TPP1000 500 Mhz and 1 Ghz 10X Passive Probes Information
203
Operating Information
203
Connecting the Probe to the Oscilloscope
203
Compensating the Probe with MDO4000 Series Oscilloscopes
203
Standard Accessories
203
Optional Accessories
205
Replacing the Probe Tip
205
Specifications
206
Performance Graphs
206
Safety Summary
208
Appendix C: P6616 General-Purpose Logic Probe Information
210
Product Description
210
Connecting the Probe to the Oscilloscope
210
Connecting the Probe to Your Circuit
211
Functional Check
211
Typical Application
212
Accessories
212
Specifications
213
Safety Summary
214
Safety Terms and Symbols in this Manual
214
Advertisement
Tektronix MDO4054-3 Instructions Manual (19 pages)
MDO4000 Series
Brand:
Tektronix
| Category:
Test Equipment
| Size: 0.3 MB
Table of Contents
Table of Contents
3
Preface
5
Clear and Sanitize Procedures
9
Memory Devices
10
Data Export Devices
12
Sanitizing an Application Module
13
Built-In Security Features
15
Disable the LAN Port and Clear LAN Ethernet Settings
17
Disable the USB Device Port
18
Clear and Sanitize a Nonfunctional Instrument
19
Advertisement
Related Products
Tektronix MDO4000C Series
Tektronix MDO4000 Series
Tektronix MDO4054-6
Tektronix MDO4034-3
Tektronix MDO4014-3
Tektronix MDO4054
Tektronix MDO4000B Series
Tektronix MDO4024C
Tektronix MDO4054C
Tektronix MDO4034C
Tektronix Categories
Test Equipment
Measuring Instruments
Amplifier
Portable Generator
Printer
More Tektronix Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL