Sign In
Upload
Manuals
Brands
Siemens Manuals
All in One Printer
ACUSON Antares
User Manuals: Siemens ACUSON Antares Ultrasound Machine
Manuals and User Guides for Siemens ACUSON Antares Ultrasound Machine. We have
1
Siemens ACUSON Antares Ultrasound Machine manual available for free PDF download: Instructions For Use Manual
Siemens ACUSON Antares Instructions For Use Manual (230 pages)
Ultrasound Imaging System
Brand:
Siemens
| Category:
All in One Printer
| Size: 4.37 MB
Table of Contents
1 Introduction
11
Table of Contents
11
System Overview
13
Configurations
14
Language Formats
14
Intended Use
15
Operating Modes
16
Image Screen Layout
17
Screen Saver
17
Sample Image Screen
18
Image Task Card
19
Documentation Devices
20
Patient Data Management
21
Measurements and Reports
22
System Presets
22
User-Defined Exam Type
22
2 Safety and Care
23
Operating Safety and Environment
25
System Symbols
25
Labels
30
Biohazard Considerations
33
Acoustic Output Mechanical and Thermal Indices
34
Mechanical and Thermal Indices
34
Transmit Power Control
35
Transmit Power Display
35
Imaging Functions that Change Acoustic Output
36
Transducer Surface Temperature Limits
37
Electrical Safety
38
Level of Protection against Electrical Shock System
39
Level of Protection against Electrical Shock Transducers
39
Possible Combinations with Other Equipment
40
Maintaining Data Integrity
41
Caring for the Ultrasound System
42
Daily Checklist
42
Maintenance
43
Repair
43
Siemens Authorized Care
43
Caring for Documentation and Storage Devices
45
Caring for the Battery Pack
45
Battery Pack Replacement and Disposal
46
Battery Pack Location
47
Removing the Battery Pack
49
Installing a Battery Pack
50
Battery Pack Disposal
51
Cleaning and Disinfecting
52
Cleaning Ultrasound System Surfaces
52
Cleaning the Air Filters
56
Caring for Transducers
60
Protective Case
61
Repair
61
Storage
61
Cleaning and Disinfecting Transducers
62
IPX8 Immersion Levels
64
Approved List of Disinfectants
65
Sterilizing Transducers VF13-5SP
66
Caring for Transducer Accessories
67
Storage
67
Transducer Sheaths
67
Gel Pad
68
Storage
68
Needle Guide Bracket Kits
69
Storage and Transportation
69
Cleaning, Disinfecting, and Sterilizing Transducer Accessories
70
Needle Guide Bracket Kits
70
3 System Controls
73
Control Panel
77
Control Panel Overlays
77
Control Panel Lighting
78
Mode Controls
78
Select
81
Trackball Controls
81
Update View
82
Priority Tool
83
Next
84
Archiving Controls
85
Freeze
85
CINE Wheel
86
Clip/Vol Save
86
Vcr
86
Depth
87
Focus
87
Image Controls
87
Print/Store
87
Menu Control
88
Zoom
88
Universal 2
89
Universal 1
90
Depth-Gain Compensation
91
Other Controls
91
Speaker Microphone
91
Transmit Power
91
Keyboard
92
Shortcut Keys
92
Browser
93
Film
93
Function Keys
93
Help
93
Patient
93
Presets
93
Report
93
Annotation Cursor
94
Arrow
94
Clear Screen
94
Hide Text
94
Home
94
Other Alphanumeric Keys
94
Set Home
94
Text A, Text B, Text C, Text D
94
Alt
95
Alt Gr
95
Arrows
95
Clear Line
95
Marker
95
Picto
95
Backspace
96
Blank
96
Caps Lock
96
End
96
Enter
96
Shift
96
Space
96
Tab
96
Footswitch
97
Task Cards
97
2D-Mode Parameter Menu Selections
98
Image Task Card
98
Parameter Menu Selections
98
M-Mode Parameter Menu Selections
100
Color Parameter Menu Selections
101
Power Parameter Menu Selections
102
Doppler Parameter Menu Selections
103
Drop-Down Menus and Group Boxes
104
Exam Type Drop-Down Menu
104
Imaging Group Box
104
Transducer Drop-Down Menu
104
Physio Group Box
109
Protocol Group Box
110
VCR Group Box
110
Foursight 4D Imaging
111
Foursight Parameter Menu Selections
111
Foursight Editing Group Box
115
Foursight Animation Group Box
116
CINE Graphics
117
Calcs Task Card
118
Text/Picto (Text) Group Box
119
Basic Measurement Tools 2D-Mode
120
Basic Measurement Tools Doppler
120
Basic Measurement Tools M-Mode
120
Display Menu
121
Review Task Card
121
Buttons
122
Image Management Tools
122
Image Selection Tools
122
Color Siescape Parameter Menu Selections (Option)
123
Compose Task Card
123
Siescape Parameter Menu Selections (Option)
123
3-Scape Parameter Menu Selections (Option)
124
General Selections for 3-Scape Imaging
124
2D-Mode-Specific Selections for 3-Scape Imaging
126
Power Mode-Specific Selections for 3-Scape Imaging
128
3-Scape Editing Group Box (Option)
130
3-Scape Animation Group Box (Option)
131
Filming Screen
132
Filming Screen Tools
132
Filming Screen Tab Card
133
Images Tab
133
Layout Tab
133
Camera Tab
134
Film Job Management Selections
134
Filming Shortcut Menus
134
Image Management Selections
134
Patient Browser Screen
135
Icon Selections
136
Menu Selections
137
Patient Menu Selections
137
Transfer Menu Selections
138
Edit Menu Selections
140
View Menu Selections
141
Filter Menu Selections
142
Sort Menu Selections
143
Help Menu Selections
144
Options Menu Selections
144
4 System Setup
145
Daily Checklist
147
Initial Setup
147
System Review
148
Moving the System
151
Using the Front Brakes
151
Using the Rear Brakes
152
During the Move
153
Prior to the Move
153
After the Move
154
Shipping the System
154
AC Tray Panel
155
Plugging in the System
155
System Startup
155
Supplying Power to the System
156
Mobile Quikstart for Portable Studies (Standby)
157
Adjusting Controls on the Monitor
158
Degaussing the Monitor
160
Testing the Monitor
160
Connecting and Disconnecting Transducers
161
Array Transducers
162
Protective Transducer Holder
163
Transducer Cable Management
164
Connecting System Accessories
165
Footswitch
165
Front System Panel
165
Physio Cables
165
Input/Output Panel Connections
166
Connecting Peripheral Equipment
167
On-Board Vs. Off-Board Documentation Devices
169
System Ergonomics
170
Assigning Functions to the Print/Store Keys
171
Configuring the Print/Store Function
171
Choosing the Output Format for Images
173
Selecting Image Text for Display
174
Configuring Additional Storage
175
Configuring Print Preferences
176
Configuring Printer Properties
177
Optimizing the Sony UP-D23 MD Printer Configuration
178
5 Beginning an Examination
181
Patient Registration
183
Registering or Pre-Registering a Patient
183
Selecting a Scheduled Procedure for Registration
186
Fields in the Patient Registration Form
187
Patient Data
187
History (ob or GYN Study)
188
Exam
189
Institution
189
Correcting Registration Data
190
During the Examination
190
Study Type Selection
191
Transducer Selection
191
Optimizing the Image
192
Selecting an Imaging Mode
192
Images in the Review Task Card
193
Printing and Storing Images
193
Storing and Viewing Clips
193
Storing Clips
194
Printing and Storing Images from Clips
195
Viewing Clips
195
Accessing a Patient Report
196
Activating the Measurement Function
196
Using the Patient Report
196
Printing and Storing the Patient Report
197
Controlling the VCR from the Ultrasound System
198
Examination Completion
199
6 Technical Description
201
Operator Control Panel
203
Processing Power
203
Standard Features
203
System Operating Software
203
15-Inch (38 CM), High Resolution Color Monitor
204
Mobility
204
Transducer Technology
204
User-Accessible Connections
204
Formats
205
General (2D) Imaging Features
205
Mixed Modes
205
Operating Modes
205
Single Modes
205
Pulsed Wave Doppler Features
206
Color Doppler Features
207
Power Doppler Features
207
Clips
208
Ensemble Tissue Harmonic Imaging
208
M-Mode Features
208
Post-Processing Features in Freeze Frame or CINE
209
Clarify VE
210
Extend Performance Technology
210
Mobile Quikstart for Portable Studies (Standby)
210
Optional Features
210
Color Siescape Panoramic Imaging
211
Sieclear Multi-View Spatial Compounding
211
Siescape Panoramic Imaging
211
3-Scape Real-Time 3D Imaging
212
Foursight 4D Imaging
212
Spectral TEQ Ultrasound Technology (TEQ Technology for Pulsed Wave Doppler)
212
TEQ Technology
212
Cadence Contrast Agent Imaging
213
Options
214
Standard Mainframe Package
214
General 2D-Mode Measurements
215
General Doppler Measurements
215
General Functions
215
General M-Mode Measurements
215
Measurements and Reports
215
Abdominal
216
Application-Specific Measurements
216
Gynecology
216
Obstetrics (OB)
217
Fetal Echo
218
Pediatric
218
Urology
218
Vascular
218
Clinical Measurements: Range and Accuracy
219
Measurement Range and Accuracy
219
M-Mode Measurements
222
Mixed Mode Measurements
222
Mode Measurements
222
Image Display
223
Possible Combinations with Other Equipment
225
Power Supply Requirements
225
System Requirements
225
Audio, Video, and Data Transmission Connections Input and Output Signals
226
Leakage Currents
226
Video Standard
226
Environmental Requirements
227
Maximum Physical Dimensions
227
Protective Measures
227
System Classifications
228
Acoustic Output Standards
229
CE Declaration
229
Design Standards
229
Quality Standards
229
Standards Compliance
229
Advertisement
Advertisement
Related Products
Siemens ACUSON Cypress
Siemens ACUSON Freestyle
Siemens ACUSON X300
Siemens ACUSON P500
Siemens ACUSON S Series
Siemens ACUSON Sequoia
Siemens ACUSON Redwood
Siemens ACUSON Juniper
Siemens ACUSON P300
Siemens acuson Sequoia
Siemens Categories
Industrial Equipment
Controller
Oven
Control Unit
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL