Siemens 6RA70 Series Manuals
Manuals and User Guides for Siemens 6RA70 Series. We have
2
Siemens 6RA70 Series manuals available for free PDF download: Instructions Manual, Faq
Siemens 6RA70 Series Instructions Manual (233 pages)
Microprocessor-based converters from 15A to 1680A for variable speed DC drives
Brand:
Siemens
| Category:
DC Drives
| Size: 2.95 MB
Table of Contents
Contents
2
Converter Software Version
2
Table of Contents
3
Definitions
6
Safety Information
6
Danger Warning
7
Special Note
7
Caution: Electro-Statically Sensitive Devices
8
Base Drive Panel Description
10
General Information
10
Card Rack Assembly
11
Rated DC Current
11
Base Drive Panel Catalog Numbers
12
Parts and Service
12
Service
13
Technical Assistance
13
Option Part Numbers
14
Cables
15
Printed Circuit Boards
15
Spare Parts
15
Armature Converter Thyristor Modules, (for 1-Quad Drives)
16
Fans/Blowers
16
Thyristors & Diodes
16
Armature Converter Thyristor Modules, (for 4-Quad Drives)
17
Field Converter Diode Modules
17
Field Converter Thyristor Modules
17
Armature Converter AC Line Fuses, (1PFU - 3 PFU)
18
Armature Converter DC Fuses, 4-Quad Only, (4PFU)
18
Power Fuses
18
Control Transformer Primary Fuses (1CFU, 2CFU)
19
Control Transformer Secondary Fuse (3CFU)
19
Field Converter AC Line Fuses (1 & 2FSFU)
19
Auxiliary Relay, (EN), and Rectifier Bridge, (MREC)
20
Contactor Coil Suppressor (1SP, ENSP)
20
Control Transformer (1CTR, 2CTR, 3CTR)
20
Main Contactor (M)
20
Procedure for Shipping Damage
24
Receiving, Unpacking
24
15ADC to 100ADC Base Drive Panels, 3AC 460V, 1 & 4Q
26
Technical Data
26
140ADC to 850ADC Base Drive Panels, 3AC 460V, 1 & 4Q Data
27
1180ADC, 1660ADC & 1680ADC Base Drive Panels, 3AC 460V, 1 & 4Q Data
28
Load Values, (DC Current)
29
Applicable Standards
30
Details of Overload Capability
30
Requirements to Achieve Control Stability
30
Installation and Dimensions
32
Installation Information
32
15 - 30 Amp Base Drive Panels Diagram
33
Base Drive Panel Outlines
33
60 Amp Base Drive Panels Diagram
34
100 Amp Base Drive Panels Diagram
35
140 Amp Base Drive Panels Diagram
36
210 Amp Base Drive Panel Diagram
37
255 Amp Base Drive Panel Diagram
38
430 Amp Base Drive Panel Diagram
39
510 Amp Base Drive Panel Diagram
40
850 Amp Base Drive Panel Diagram
41
1180 Amp Base Drive Panel Diagram
42
1660 Amp Base Drive Panel Diagram
43
1680 Amp Base Drive Panel Diagram
44
Base Drive Panel Connections
46
Base Drive Panel Schematics
47
Base Drive Panel, 15 Amps, 1 & 4 Quad Schematics
47
Base Drive Panel, 30 Amps, 1 & 4 Quad Schematics
48
Base Drive Panel, 60 Amps, 1 & 4 Quad Schematics
49
Base Drive Panel, 100 Amps, 1 & 4 Quad Schematics
50
Base Drive Panel, 140 Amps, 1 & 4 Quad Schematics
51
Base Drive Panel, 210 Amps, 1 & 4 Quad Schematics
52
Base Drive Panel, 255 Amps, 1 & 4 Quad Schematics
53
Base Drive Panel, 430 Amps, 1 & 4 Quad Schematics
54
Base Drive Panel, 510 Amps, 1 & 4 Quad Schematics
55
Base Drive Panel, 850 Amps, 1 & 4 Quad Schematics
56
Base Drive Panel, 1180 Amps, 1 & 4 Quad Schematics
57
Base Drive Panel, 1660 Amps, 1 & 4 Quad Schematics
58
Base Drive Panel, 1680 Amps, 1 & 4 Quad Schematics
59
Control Connections CUD1
61
Terminal Locations CUD1
62
Control Connections CUD2
63
Optional CUD2 Control Connections
63
Terminal Locations CUD2
64
Base Drive Panel Power Connections 140 to 255 Amp
65
Base Drive Panel Power Connections 15 to 100 Amp
65
Description of Power/Control Terminals
65
Base Drive Panel Control Connections, (CTB), 15 to 1680 Amp
66
Base Drive Panel Power Connections 430 to 1680 Amp
66
Current Requirement for Terminals 87, 89 if Supplied from a Separate Source
67
Electronics Power Supply, Main Contactor, Fans (if Used) 15 to 850 Amp
67
Motor Armature Circuit
67
Motor Field Circuit
67
Electronics Power Supply, Main Contactor, and Fans 1180 to 1680 Amps
68
Remote Relay Enable Terminals: 430 Amp to 1680 Amp Base Drive Panels
68
General Safety Information for Start-Up
70
Start-Up
70
Operator Control Panels
71
Simple Operator Control Panel (PMU “Parameterization Unit“)
71
LED Displays
72
User-Friendly Operator Control Panel (OP1S)
72
Alarm Messages
73
Parameter Types
73
Parameterization on Simple Operator Control Panel
73
Parameterization Procedure
73
Configured with Analog Speed Setpoint and Start/Stop Control by Contacts
75
Typical Connection Diagrams
75
Configured with Analog Speed Setpoint and Push-Button Start/Stop Control
76
Reset to Factory Default Values and Adjust Offsets
77
Start-Up Procedure
78
Access Authorization
79
Adjustment of Converter Rated Currents
79
Adjustment to Actual Converter Supply Voltage
79
Input of Motor Data, Actual Speed Sensing Data
79
Matching to Pulse Encoder Signal Voltage
80
Number of Pulses of Pulse Encoder (in Pulses/Revolution)
80
Operation with Pulse Encoder
80
Setting the Maximum Operating Speed for Pulse Encoder Operation (in Revolutions/Minute)
80
Current Limits
81
Field Data
81
Ramp-Function Generator
81
Selection of Basic Technological Functions
81
Execution of Optimization Runs
82
P051 = 25 - Optimization Run for Precontrol and Current Controller for Armature and Field
82
P051 = 26 - Speed Controller Optimization Run
83
P051 = 27 - Optimization Run for Field Weakening
83
P051 = 28 - Optimization Run for Compensation of Friction Moment and Moment of Inertia
84
Checking and Possible Fine Adjustment of Maximum Speed
85
Setting Application Functions
85
Starting the Drive
85
Speed Setpoint Selection
86
Jog (Inching) Configuration
87
Documentation of Setting Values
88
Fault Message Display
90
Fault Messages
90
Faults and Alarms
90
General Information about Faults
90
F001 - Failure of Electronics Power Supply (Active in All Operating States)
91
List of Fault Messages
91
Supply Faults
91
F004 - Phase Failure in Armature Supply (Active in Operating States of ≤ O4)
92
F005 - Fault in the Field Circuit (Active in Operating States of ≤ O5)
92
F006 - Undervoltage (Active in Operating States of ≤ O4)
93
F007 - Overvoltage (Active in Operating States of ≤ O4)
93
F008 Line Frequency Less than the Minimum Line Frequency Acc. to Parameter P363 (Active in Operating States of ≤ 05)
94
F009 Line Frequency Greater than the Maximum Line Frequency Acc. to Parameter P364 (Active in Operating States of ≤ 05)
94
F011 Telegram Failure at GSST1
94
Interface Error
94
F012 Telegram Failure at GSST2
95
F013 Telegram Failure at GSST3
95
F014 Telegram Failure at Paralleling Interface (Active When U800 = 1 or 2 from the First Receipt of a Valid Protocol in All Operating States)
95
External Faults
96
F024 Fault Message from Free Function Block FB3 (Active in All Operating States)
97
F025 Brush Length too Short (Active in Operating States of ≤ 03)
97
F028 Motor Overtemperature (Active in Operating States of ≤ O6)
97
Fault Messages from Motor Sensors
97
Drive Faults
98
F029 Motor Overtemperature (Active in All Operating States)
98
F030 Commutation Failure or Overcurrent Has Occurred (Active in Operating States of – –, I, II)
98
F033 Fault Message from Free Function Block FB4 (Active in All Operating States)
98
F034 Fault Message from Free Function Block FB5 (Active in All Operating States)
99
F035 Drive Is Blocked (Active in Operating States of – –, I, II)
99
F036 no Armature Current Is Flowing (Active in Operating States of – –, I, II)
99
F038 Overspeed (Active in Operating States of – –, I, II)
99
F039 2 T Power Section Monitor Has Responded (Active in Operating States of – –, I, II)
100
F040 Electronics Supply Disconnected in Active Fault Status (Active in All Operating States)
100
F041 Ambiguous Selection of Parameter Set or Ramp-Function Generator (Active in All Operating States)
100
F042 Tachometer Fault
101
F043 EMF too High for Braking Operation
102
F044 a Slave Connected to the Paralleling Interface Is Not Operating
102
F046 Analog Select Input for Main Setpoint (Terminals 4 and 5) Faulty
102
F047 Analog Select Input 1 (Terminals 6 and 7) Is Faulty
102
F048 Fault in Measuring Channel for Digital Speed Sensing Using Pulse Encoder
103
F050 Optimization Run Not Possible
103
Start-Up Faults
103
F051 no Optimization Run When Permanent Memory Is Disabled
108
F052 Optimization Run Aborted as a Result of External Cause
108
F053 Fault Message from Free Function Block FB288
108
F054 Fault Message from Free Function Block FB289
108
F055 no Field Characteristic Recorded
109
F056 Important Parameter Is Not Set
109
F058 Parameter Settings Are Not Consistent
109
F059 Technology Option S00 Is Disabled/Will be Disabled Soon
109
F061 Fault Message from Thyristor Check Function
111
Hardware Faults
111
F062 Fault in Parameter Memory
112
Internal Faults
112
F063 Errors in Compensation Data of Analog Inputs and Outputs
113
F064 Watchdog Timer Has Initiated a Reset
113
F065 Illegal Microprocessor Status
113
F067 Converter Cooling Faulty
113
Communication Errors with Supplementary Boards
114
F068 Analog Measuring Channel Faulty (Main Setpoint, Main Actual Value or Analog Select Input)
114
F069 MLFB Data Are Faulty
114
F070 SCB1: Serious Initialization Error
114
F078 SCB1: Current below 4Ma Minimum Value at Analog Input3 of Slave 2
115
F079 SCB1: Telegram Failure
115
F080 Error in Initialization of a CB/TB Board
115
F082 CB/TB Message Timeout or Error in Data Exchange
115
Fault Messages from Supplementary Boards
116
A015 Simolink Start
117
A024 Alarm Message from Free Function Block FB7
117
Alarm Message Display
117
Alarm Messages
117
A025 Brush Length too Short
118
A026 Poor Bearing Condition
118
A027 Air Flow Monitoring
118
A031 Speed Controller Monitoring
118
A033 Alarm Message from Free Function Block FB8
119
A034 Alarm Message from Free Function Block FB9
119
A043 Automatic Field Current Reduction if EMF Is too High in Operation
119
A047 Analog Select Input 1 (Terminals 6 and 7) Faulty
119
A049 SCB1: no SCI Slave Connected
120
A050 SCB1: Not All Required SCI Slaves Are Available
120
A067 Converter Cooling Faulty
120
A097 - A128 TB Alarms
120
Overview
122
Parameter List
122
Range of Parameter Numbers Function
122
Overview of Abbreviations
124
Operating Status Display
126
General Visualization Parameters
128
Connector and Binector Displays
131
Access Authorization Levels
132
P050 Language
132
P051 Key Parameters
132
P052 Selection of Display Parameters
132
P053 Control Word for the Permanent Memory
133
P054 OP1S – Background Lighting
133
P055 Copy Function Data Set
133
P057 Copy Bico Data Set
133
Definition of SIMOREG DC MASTER Converter
134
R061 Creation Date of Software
134
R062 Checksum
134
R063 Board Code
134
P067 Load Class
135
R064 Board Compatibility
135
R065 Software Identifiers
135
R068 Options According to Rating Plate
135
P075 Control Word for Power Section
136
R069 Serial Number of SIMOREG DC Master Converter
136
R072 Converter Rated DC Current (Armature)
136
R073 Converter Rated DC Current (Field)
136
P076 Reduction of Converter Rated DC Current
137
P077 Total Thermal Reduction Factor
137
P078 Reduction of Converter Rated Supply Voltage
137
P079 Short Pulses / Long Pulses, Armature Gating Unit
137
P080 Control Word for Brake Control
138
P081 EMF-Dependent Field Weakening
138
Setting Values for Converter Control
138
P082 Operating Mode for Field
139
P083 Selection of Actual Speed Value
140
P084 Selection of Closed-Loop Speed / Current or Torque Control
140
P085 Wait Period after Cancellation of Inching Command
140
P087 Brake Release Time
140
P088 Brake Closing Time
141
P089 Maximum Wait Time for Voltage to Appear at Power Section
141
P090 Stabilization Time for Line Voltage
141
P091 Setpoint Threshold
141
P092 Delay Times for Field Reversal
142
P093 Pick-Up Delay for Line Contactor
142
P094 Switch-Off Delay for Auxiliaries
142
P096 After-Running Time for the Device Fan
142
Definition of Motor
143
P098 Contactor in DC Circuit
143
P100 Rated Motor Armature Current (Acc. to Motor Rating Plate)
143
P107 Armaure Current I2 (Acc. to Motor Rating Plate)
143
P108 Maximum Operating Speed N3
144
P115 EMF at Maximum Speed in Operation Without Tachometer
144
P117 Control Word for Field Characteristic
144
P118 Rated EMF Value
144
Magnetization Characteristic (Field Characteristic)
145
Example of a Field Characteristic
147
Definition of Pulse Encoder, Speed Sensing Using Pulse Encoder
148
P140 Selection of Pulse Encoder Type
149
P141 Number of Pulses of Pulse Encoder
149
P142 Matching to Pulse Encoder Signal Voltage
149
P143 Setting the Maximum Speed for Pulse Encoder Operation
150
P144 Multiple Evaluation of Encoder Signals
150
P145 Automatic Measuring Range Switchover for Measurement of Low Speeds - Switchover of Multiple Evaluation
150
P146 Automatic Measuring Range Switchover for Measurement of Low Speeds - Switchover of Measuring Time
150
Closed-Loop Armature Current Control,Auto-Reversing Stage,Armature Gating Unit
151
P150 Alpha G Limit (Armature)
151
P151 Alpha W Limit (Armature)
151
P153 Control Word for the Armature Precontrol
151
P154 Set Armature Current Controller I Component to Zero
152
P156 Armature Current Controller Reset Time
152
P159 Switchover Threshold for Auto-Reversing Stage (Armature)
152
P162 EMF Calculation Method for Armature Precontrol
152
Current Limitation, Torque Limitation
153
P169 Select Closed-Loop Torque / Current Control
153
P170 Select Closed-Loop Torque / Current Control
153
P173 Source for "Torque Control / Current Control" Switchover
153
P176 Source for Variable Integration Time
154
P177 Source for the Command "No Immediate Pulse Disable"
154
P180 Positive Torque Limit 1
154
P181 Negative Torque Limit 1
154
Auto-Reversing Stage, Armature Gating Unit
155
P200 Filter Time for Actual Speed Controller Value
155
P201 Band-Stop 1: Resonant Frequency
155
Speed Controller
155
P221 Speed Controller: Hysteresis for Speed-Dependent PI/P Controller Switchover
156
P228 Filter Time for Speed Setpoint
156
Setting Values for Speed Controller
156
Speed Controller Droop
156
Closed-Loop Field Current Control, Field Gating Unit
157
P250 Alpha G Limit (Field)
157
P251 Alpha W Limit (Field)
157
P252 Filtering of Line Frequency Correction (Field)
157
P256 Field Current Controller Reset Time
158
P257 Standstill Field
158
P264 Set Field Current Controller P Component to Zero
158
P265 Source for Selection of External Field Current Monitoring Signal
158
Closed Loop EMF Control
159
P272 Operating Mode of Closed-Loop EMF Control
159
P273 Control Word for EMF Controller Precontrol
159
P283 Filter Time for Actual Value for EMF Controller Precontrol
159
Ramp-Function Generator Table
160
P302 Select Ramp-Function Generator / Ramp-Up Integrator Mode
161
Ramp-Function Generator Parameter Set 1 (See also Parameter P330)
161
Ramp-Function Generator Parameter Set 2 (See also Parameter P330)
161
Ramp-Function Generator Parameter Set 3 (See also Parameter P330)
161
P317 Ramp-Function Generator Tracking
162
P318 Set Ramp-Function Generator Output
162
P319 Delay Time for Enabling Ramp-Function Generator
162
Setpoint Processing
162
P330 Factor for Ramp-Function Generator Times
163
P351 Threshold for Undervoltage Trip
163
P357 Threshold for Tachometer Interruption Monitoring
163
Setting Values for Monitoring Functions and Limits
163
P360 Response Delay for External Faults and Alarms
164
P362 Delay Time for the Overvoltage Monitoring
164
P363 Threshold for the Minimum Line Frequency
164
Setting Values for Limit-Value Monitors
164
I F < I F Min Signal
165
Overspeed
165
Setpoint/Actual Value Deviation 1
165
Setpoint/Actual Value Deviation 2
165
I F < I F X Signal
166
P398 Field Current Threshold I F X
166
P399 Hysteresis for I F < I F X Signal
166
Settable Fixed Values
166
Digital Setpoint Input (Fixed Setpoint, Inching and Crawling Setpoints)
167
Fixed Control Bits
167
P430 Source for Fixed-Setpoint Injection
167
Crawling Setpoint
168
Inching Setpoint
168
P435 Source for Injection of Inching Setpoint
168
P438 Source for Standard Setpoint
168
P450 Resetting of Position Counter
169
P451 Position Counter Hysteresis
169
P452 Source for "Reset Position Counter" Command
169
Position Sensing with Pulse Encoder
169
Connector Selector Switches
170
Motorized Potentiometer
170
P455 Source for Inputs of Connector Selector Switch 1
170
P460 Control Word for Motorized Potentiometer Ramp-Function Generator
170
P464 Time Difference for Dy/Dt
171
P465 Factor of Expansion for Motorized Potentiometer
171
P472 Source for Set Motorized Potentiometer
171
P473 Storage of Output Value
171
Definition of "Motor Interface"
172
Oscillation
172
P490 Selection of Temperature Sensor for Analog Monitoring of Motor Temperature
172
P491 Analog Monitoring of Motor Temperature: Alarm Temperature
172
P492 Analog Monitoring of Motor Temperature: Trip Temperature
173
P495 Brush Length Sensing: Tripping of Alarm or Fault Message
173
P496 Bearing Condition: Tripping of Alarm or Fault Message
173
P497 Air Flow: Tripping of Alarm or Fault Message
173
Configuring of Torque Shell Input
174
P509 Source for Input Quantity (N-Act) of Speed Limiting Controller
174
P515 P Gain of Speed Limiting Controller
174
Speed Limiting Controller
174
Friction Compensation
175
P519 Source for Input Signal of the Friction Compensation [SW 2.0 and Later]
175
P520 Friction at 0% Speed
175
P530 Friction at 100% Speed and Higher
175
Compensation of Moment of Inertia (DV/Dt Injection)
176
P540 Acceleration Time
176
P542 Time Difference for Dy/Dt of Ramp-Function Generator
176
P543 Threshold for SAD-Dependent Acceleration
176
P550 P Gain in the Adaptation Range
177
P551 Integration Time in the Adaptation Range
177
P554 Source for the Influencing Quantity of the Tn-Adaptation
177
Speed Controller Table
177
P555 Source for the Influencing Quantity of the Droop Adaptation
178
P556 Adaptation N Controller P Gain: Threshold 1
178
P562 Positive Speed Droop Limitation
178
Speed Controller Optimization for Drives with Oscillating Mechanical System
178
Field Reversal
179
Input Quantities for Signals
179
P590 Source for Setpoint of “Nset = Nact Signal 1”
179
P591 Source for Actual Value of "N-Set = N-Act Signal 1"
179
Configuring of Closed-Loop Control
180
P595 Source for Actual Value of "Overspeed Signal”
180
P597 Source for Actual Value of “Nset = Nact Signal 2”
180
P600 Source for Gating Unit Input (Armature)
180
P601 Source for Armature Current Controller Setpoint
181
P602 Source for Armature Current Controller Actual Value
181
P603 Source for Variable Current Limit in Torque Direction I
181
P604 Source for Variable Current Limit in Torque Direction II
182
P605 Source for Variable Positive Torque Limit
182
P606 Source for Variable Negative Torque Limit
182
P607 Source for Torque Setpoint for Master Drive
182
P609 Source for Actual Speed Controller Value
183
P610 Source for Gating Unit Input (Field)
183
P614 Source for Variable Field Current Setpoint Lower Limit
183
Setting Values for Configuring of Closed-Loop Field and EMF Control
183
Configuring of Injection of Acceleration Value
184
P615 Source for EMF Controller Setpoint
184
P616 Source for Actual EMF Controller Value
184
Speed Controller, Setpoint/Actual Value Deviation
184
P631 Source for Setting Value for Speed Controller Integrator
185
P632 Source for Variable Positive Limitation at Ramp-Function Generator Output
185
P633 Source for Variable Negative Limitation at Ramp-Function Generator Output
185
Setting Values for Configuring the Setpoint Processing Function and Ramp-Function Generator
185
P634 Source for Limitation Input at Ramp-Function Generator Output
186
P636 Source for Reduction Signal for Ramp-Function Generator Times
186
P639 Source for the Ramp-Function Generator Setting Values
186
P640 Source for Selection of "Set Ramp-Function Generator”
186
P641 Source for Selection of "Bypass Ramp-Function Generator”
187
P643 Source for Variable Negative Limitation of Main Setpoint
187
P646 Source for Enable Signal for Ramp-Up Integrator Switchover
187
P647 Source for Enable Signal for Ramp-Function Generator Tracking
187
Control Word, Status Word
188
Display of Control Words 1 and 2
188
Display of Status Words 1 and 2
188
Control Word 1
189
Control Word 2
190
Further Configuring Measures
191
P692 Source for Selection of Injection of Standstill Field
191
P693 Source for Selection of Enabling Command for EMF Controller
191
P695 Source for Selection of "Set Speed Controller I Component" Function
191
Analog Inputs (Main Actual Value, Main Setpoint, Selectable Inputs)
192
P700 Signal Type of "Main Setpoint" Analog Input
192
P701 Normalization of "Main Setpoint" Analog Input
192
P705 Filtering Time for "Main Setpoint" Analog Input
192
Analog Input Terminals 6 / 7 (Analog Selectable Input 1)
193
P706 Source for Enabling of "Main Setpoint" Analog Input
193
P707 Resolution of "Main Setpoint" Analog Input
193
P713 Mode of Signal Injection at "Analog Selectable Input 1"
193
Analog Input Terminals 8 / 9 (Analog Selectable Input 2)
194
P714 Source for Selection of Sign Reversal at "Analog Selectable Input 1"
194
P716 Source for Enabling of "Analog Selectable Input 1"
194
P726 Source for Enabling of "Analog Selectable Input 2"
194
Analog Input Terminals 10 / 11 (Analog Selectable Input 3)
195
Analog Input Terminals 103 / 104 (Main Actual Value)
195
P741 Normalization for "Main Actual Value”
195
P744 Source for Selection of Sign Reversal at "Main Actual Value" Analog Input
195
Analog Output Terminals 12/13 (Actual Current Display)
196
Analog Output Terminals 14/15
196
Analog Output Terminals 16/17
196
P757 Filtering Time for Analog Output 2
196
Analog Output Terminals 18/19
197
Analog Output Terminals 20/21
197
P765 Source for Output Value at Analog Output 4
197
P768 Normalization of Analog Output 4
197
Binary Outputs
198
P770 Control Word for Binary Selectable Outputs
198
P777 Delay for Output Value at Binary Output 3
198
P778 Delay for Output Value at Binary Output 4
198
Configuration of Serial Interfaces on Basic Converter
199
P780 Selection of Protocol for G-SST1 Basic Converter Interface
199
P784 Source for Transmit Data for G-SST1
199
P785 Options for G-SST1
199
P786 USS Bus Address for G-SST1
200
P787 Telegram Failure Time for G-SST1
200
P788 Source for Activation of F011
200
P790 Selection of Protocol for G-SST2 Basic Converter Interface
200
P791 Number of Process Data for G-SST2
201
P792 Length of Parameter Jobs for G-SST2
201
P793 Baud Rate for G-SST2
201
P794 Source for Transmit Data for G-SST2
201
P795 Options for G-SST2
202
P796 USS Bus Address for G-SST2
202
P797 Telegram Failure Time for G-SST2
202
P798 Source for Activation of F012
202
P800 Selection of Protocol for G-SST3 Basic Converter Interface
203
P801 Number of Process Data for G-SST3
203
P802 Length of Parameter Jobs for G-SST3
203
R799 Diagnostic Information for G-SST2
203
P803 Baud Rate for G-SST3
204
P804 Source for Transmit Data for G-SST3
204
P805 Options for G-SST3
204
P806 USS Bus Address for G-SST3
204
P807 Telegram Failure Time for G-SST3
205
P808 Source for Activation of F013
205
R809 Diagnostic Information for G-SST3
205
R810 Receive Data on G-SST1
206
R811 Transmit Data on G-SST1
206
R812 Receive Data on G-SST2
206
R813 Transmit Data on G-SST2
206
Peer-To-Peer Interfaces: Enable Transmission and Receipt of Telegrams
207
R814 Receive Data on G-SST3
207
R815 Transmit Data on G-SST3
207
Compensation Values
208
Deactivation of Monitoring Functions
208
P825 Offset Compensation for Actual Field Current Channel
208
P826 Correction of Natural Commutation Timing
208
P927 Parameterization Enable
209
Parameters for Drivemonitor and OP1S
209
Profile Parameters
209
Thyristor Diagnosis
209
Fault Memory
210
P952 Number of Faults
210
R949 Fault Value
210
R951 Fault Text
210
Visualization Parameters: Alarms
211
Device Identification
212
Resetting and Storing Parameters, List of Existing and Modified P and R Parameters
212
Visualization Parameters: Control and Status Word
212
P971 EEPROM Transfer
213
R980 List of Existing Parameter Numbers, Start
213
R990 List of Modified Parameter Numbers, Start
213
Basic Functions
216
Sheet 1 Legend
217
Sheet 2 Speed Setpoint System
218
Simplified Block Diagrams
216
Sheet 3 Speed Controller and Current Limit
219
Sheet 4 Armature Current Control
220
Sheet 5 EMF and Field Current Control
221
Sheet 6 USS Interface 1 ( X300 )
222
Sheet 7 USS Interface 2 ( X172 )
223
Sheet 8 Peer to Peer Interface ( X172 )
224
Sheet 9 Data Exchange CB / TB to Base (PZD)
225
Sheet 10 Control Word 1
226
Sheet 11 Control Word 2
227
Sheet 12 Status Word 1
228
Sheet 13 Status Word 2
229
Sheet 14 Signals
230
Sheet 15 Miscellaneous
231
Advertisement
Siemens 6RA70 Series Faq (4 pages)
digital, compact units for connection to a three-phase AC supply
Brand:
Siemens
| Category:
Media Converter
| Size: 0.17 MB
Advertisement
Related Products
Siemens 6SE7022-1EC85-1AA0
Siemens 6SE7027-2FC85-1AA0
Siemens 6SE7028-6EC85-1AA0
Siemens 6SE7031-4HE85-1AA0
Siemens 6SE7032-7FE85-1AA0
Siemens 6SE7022-7FC85-1AA0
Siemens 6SE7034-6EE85-1AA0
Siemens 6SE7041-0EH85-1AA0
Siemens 6SE7041-3FK85-1AA0
Siemens 6SE7041-0HH85-1AA0