Sign In
Upload
Manuals
Brands
Pacific Power Source Manuals
Portable Generator
3900AFX
Pacific Power Source 3900AFX Manuals
Manuals and User Guides for Pacific Power Source 3900AFX. We have
1
Pacific Power Source 3900AFX manual available for free PDF download: Operation Manual
Pacific Power Source 3900AFX Operation Manual (485 pages)
Programmable Power Source
Brand:
Pacific Power Source
| Category:
Portable Generator
| Size: 12.14 MB
Table of Contents
Table of Contents
3
1 Contact Information
15
2 Safety & Warranty Information
16
Limited Warranty
16
Service and Spare Parts Limited Warranty
16
Safety Information
16
Safety Notices
18
Figure 2-1: EMI AC Input Filter Residual Voltage Check after Disconnecting AC Mains Power
21
3 Product Overview
23
General Description
23
Figure 3-1: AFX Series Model Number Decoder
23
Product Features
24
Block Diagram
25
Figure 3-2: AFX Series® Basic Block Diagram
25
Controller Description
26
Measurement Read-Back
26
Accessories Included (Ship Kit)
26
Remote Control Interfaces
26
Table 3-1: Included Accessories
26
Table 3-2: Remote Control Interface
26
4 Technical Specifications
27
Single Chassis Models
27
Multiple Chassis Models
27
AC Output Mode
28
Figure 4-1: Output Voltage Distortion into Full R Load as a Function of Frequency
29
Programmable Output Impedance Ranges by Mode and Configuration
30
Table 4-1: Programmable Impedance Ranges as a Function of Phase Mode and Configuration
30
Extended Frequency Ranges - Supplemental Specs
31
Figure 4-2: 1.00Hz ~ 15.00Hz Freq. Range Power Rating in 3 Phs Mode
31
Figure 4-3: 1200Hz ~ 3000Hz Freq. Range Voltage Vs. Current- 3150AFX in 3 Phs Mode
32
Figure 4-4: 1200Hz ~ 3000Hz Extended Freq. Range Power - 3150AFX in 3 Phs Mode
32
Figure 4-5: Current Overload Vs. Time
33
Temporary Current Overload
33
AC Voltage and Current Output Charts
34
Figure 4-6: AC Mode Voltage/Current Range, AFX Models - 3 or 2-Phase Mode
34
Figure 4-7: AC Mode Voltage/Current Range, AFX Models - 1 Phase Mode
34
Extended AC Voltage Ranges - Supplemental Specs
35
Figure 4-8: Extended AC Voltage/Current Range, AFX Models - 3 or 2 Phase Mode
36
Figure 4-9: Extended AC Voltage/Current Range, AFX Models - 1 Phase Mode
36
DC Output Mode
37
DC Voltage and Current Output Charts
37
Figure 4-10: DC Mode Voltage/Current Range, AFX Models- 3 or 2 Phase Mode
37
Protection Modes
38
Figure 4-11: DC Mode Voltage/Current Range, AFX Models - 1 Phase Mode
38
Metering
39
Other Measurements
40
Transients
40
AC Input
41
Dimensions & Weight
41
Environmental
42
Safety & Regulatory
42
Figure 4-12: Dimension Drawing AFX Series® 15KW Model
42
Digital Interfaces
43
Auxiliary I/O
44
Transformer Output Voltage Range (T Option)
45
Available T Option Rating Versions
45
Figure 4-13: Rack Mount Chassis for 6Kva to 15Kva Transformer Option
45
Technical Specifications 400V Range
46
Figure 4-14: Voltage Vs Current Rating 400V Range - 3 Phase Mode
47
Figure 4-15: Voltage Vs Current Rating 400V Range - 1 Phase Mode
47
IEC413 Option
48
5 Unpacking and Installation
49
Inspection
49
Lifting and Carrying Instructions
49
Figure 4-1: Model 5L18-36 VI Curve
49
Figure 5-2: Exploded View of AFX Unit Packaging
50
Verify Correct AC Input Line Voltage
51
AC Input Connections
52
Table 5-1: AC Input Wire Size Table
53
Figure 5-3: Rear Panel Layout
54
Figure 5-4: AC Input Terminal Block - Rear Panel
54
Grounding Requirements
55
Chassis Ground Connection Required
55
Output Neutral Grounding
56
AC Input Circuit Breaker
56
Figure 5-5: Grounding Floating Neutral Output
56
Bench Use
57
Rack Mounting
57
Airflow
57
Sound Levels
58
Cleaning
59
Air Intake Filter Removal and Cleaning
59
Figure 5-6: Air Intake Filter Removal
59
Air Filter Installation
60
Air Filter Removal
60
Filter Cleaning
60
Liquids
60
Figure 5-7: Air Intake Filter and Filter Panel
60
Load Connections
61
Output Wiring and Recommended Wire Sizing
61
Three Phase Wye Load Output Connection
62
Figure 5-8: Three Phase Wye Load Output Connections - Internal Voltage Sense
63
Figure 5-9: Three Phase Wye Load Output Connections - External Voltage Sense
64
Three Phase Delta Load Output Connection
65
Figure 5-10: Three Phase Delta Load Output Connections - Internal Voltage Sense
66
Figure 5-11: Three Phase Delta Load Output Connections - External Voltage Sense
67
Single Phase Load Output Connection
68
Figure 5-12: Optional AFX Single Phase Shorting Adaptor Assembly
68
Figure 5-13: Single Phase Load Output Connections
69
External Voltage Sense Connections
70
Figure 5-14: AFX a Version External Voltage Sense Connector
71
Powering up
72
In Case of Malfunction
72
Cabinet Systems Installation
73
Standard Cabinet Sizes
73
Tools Required
73
Dimensions
74
Figure 5-15: AFX Cabinet Dimensions
74
Cabinet System AC Input Connections
75
Recommended AC Input Wire Strip Lengths
75
Figure 5-16: AFX Cabinet AC Input Connection Diagram
76
Cabinet System AC Input Neutral
77
Cabinet System Grounding
77
Recommended AC Output Wire Strip Lengths
78
Cabinet Load Connections - Three Phase WYE Loads
78
Figure 5-17: WYE Load Connection Diagram
78
Cabinet Load Connections - Three Phase Delta Loads
79
Figure 5-18: Delta Load Connection Diagram
79
Cabinet Load Connections - Single Phase Loads
80
Figure 5-19: Single Phase Load Connection Diagram
80
AFX Cabinet Systems Turn on and Turn off Procedures
81
Cabinet Power Turn on Using Circuit Breakers
81
Cabinet Power Turn off Using Circuit Breakers
81
Figure 5-20: AFX Cabinet System Power on and off Sequences
82
Cabinet System Options
83
OCS: Output Control Switch Option
83
Table 5-2: Available AFX Cabinet Options
83
Figure 5-21AFX "AG" Version Cabinet -OCS Option Wiring Diagram
83
EPO: Emergency Power off Option
84
MRC: Mode Relay Control Option
84
28UX Option
84
Figure 5-22: AFX "L" Version Cabinet -OCS Option Wiring Diagram
84
Transformer Options for Cabinet Systems
85
Interface Options
86
Rear Panel Connector Locations - "L" Versions
86
Figure 5-23: Remote Control Interface Connector Locations on Rear Panel ( L Versions)
86
Rear Panel Connector Locations - "A" Versions
87
Rear Panel Connector Locations - "AG" Versions
87
USB Device Interface
87
Table 5-3: Remote Control Interface Connector Locations on Rear Panel ( a Versions)
87
Table 5-4: Remote Control Interface Connector Locations on Rear Panel (a Versions W GPIB)
87
RS232 Serial Interface
88
Table 5-5: RS232 DB25 Tx and Rx Pin Locations
88
Table 5-6: Standard RS232 DB9 Pin Assignments
89
GPIB Device Interface (Option G)
90
Table 5-7: GPIB Interface Connector Pin Assignments
90
Remote Inhibit or Enable Input
91
Figure 5-24: Remote Inhibit Control Screen
91
Figure 5-25: Remote Inhibit Pins on DB9 for AFX-2L and AFX-4L Versions
91
External MODE Relay Control
92
LAN Interface
93
System Interface Bus Connectors
93
Figure 5-26: AFX Series® Rear Panel Layout
93
Multi-Unit Parallel Operation
94
Load Connections on Parallel Systems
94
Parallel System Bus Connection
94
Master / Master Paralleling
95
Multi-Cabinet Parallel Operation Guidelines
96
Output Wiring
96
System Grounding
97
Transformer Options
98
T Option 4U Chassis
98
Rack Mount T Option Installation
99
Unpacking T Option Chassis
100
Cabinet Installation
100
T Option Chassis Rear Panel Connectors
101
Table 5-8: Transformer Option Chassis, Rear Panel Connectors
102
AFX Power Source to T Option Connections
103
6 Front Panel Operation
104
Front Panel Layout
104
Keyboard Buttons
105
Shuttle Knob
106
PC Monitor Output
106
USB Host Ports
106
SD Card Memory Slot
106
OUTPUT ENABLE Button
107
OUTPUT State Indication
107
Energy Savings Modes
107
Output on Response Times
107
Menu Keys
108
Table 6-1: Available Menu Keys
108
PROG - PROGRAM Screens
109
Power on Settings
110
PROGRAM Output Parameters
110
Table 6-2: Available Output Parameters on PROGRAM Screen
110
Phase Rotation / Phase Sequence
111
Direct Data Entry - Presets
112
Customizing Output Programming Preset Soft Key Values
113
Changing Shuttle Programming Resolution
113
Table 6-3: Changing Programming Resolution
113
Phase Mode Selection
114
PROGRAM Soft Keys
115
Table 6-4: PROGRAM Screen Soft Keys
116
Peak Current Protection Minimum Setting
117
Available Waveforms
119
Table 6-5: Available Included AFX Series® Waveforms
120
Waveform Smoothing Filter
121
AUTO RMS Function - Steady State
122
Extended AC Voltage Range Operation
124
MEAS - MEASUREMENTS Screens
127
Measurements Screens
127
Scope Measurements
128
Harmonic Measurements
129
Measurement Screen Soft Keys
130
Table 6-6: Measurement Screen Soft Keys
131
Measurement Data Logging
132
TRAN- TRANSIENTS Screens
133
LIST Mode
133
LIST Parameters
134
Table 6-7: Available LIST Transient Parameters
134
Table 6-8: Voltage Transient List for Example 1
135
Table 6-9: RTCA/DO160 Section 16 Test Number 16.5.2.1D
136
Table 6-10: Voltage Transient List for Example 1
136
LIST Transient Edit Mode
137
LIST Transient Execution Modes
138
Table 6-11: Available TRANSIENT EDIT Screen Soft Keys
138
Table 6-12: Available TRANSIENT DEBUG Screen Soft Keys
138
Table 6-13: Available TRANSIENT PROGRAM Screen Soft Keys
139
LIST Transient Entry Modes
140
Multiple User Waveforms in LIST Transients
141
STEP or RAMP Modes
142
STEP or RAMP Parameters
143
Table 6-14: Available STEP Transient Parameters
143
Table 6-15: Available STEP PROGRAM Screen Soft Keys
143
STEP or RAMP Transient Execution Modes
144
Table 6-16: Available STEP EXECUTION Screen Soft Keys
144
PULSE Mode
145
PULSE Parameters
146
Table 6-17: Available STEP Transient Parameters
146
Table 6-18: Available STEP PROGRAM Screen Soft Keys
146
PULSE Transient Execution Modes
147
Table 6-19: Available STEP PROGRAM Screen Soft Keys
147
AUTO RMS Function - Transients
148
CONF - CONFIGURATION Screens
149
UNIT CONFIGURATION Screens
151
Table 6-20: Available UNIT CONFIGURATION 1 Screen Soft Keys
152
Table 6-21: Available UNIT CONFIGURATION 2 Screen Soft Keys
154
USER LIMITS SETTINGS Screen
155
Table 6-22: Available USER LIMITS SETTINGS Screen Soft Keys
155
RAMP TIME & SLEW RATE SETTINGS Screen
156
Table 6-23: Available RAMP TIME & SLEW RATE SETTINGS Screen Soft Keys
157
PROGRAM MEMORY Screen
158
CSC CONFIGURATION Screen
159
Table 6-24: Available SLEW RATE SETTINGS Screen Soft Keys
159
Table 6-25: Available CSC CONFIGURATION Screen Soft Keys
159
TRANSIENT SETTINGS Screen
160
Table 6-26: Available TRANSIENT SETTINGS Screen Soft Keys
160
OUTPUT IMPEDANCE Screen
161
Table 6-27: Available PROGRAMMABLE IMPEDANCE Screen Soft Keys
161
USER PRESETS Screen
162
SYST - SYSTEM Screens
164
System Menu 1
165
System Menu 2
165
ERROR / EVENT QUEUE Screen
166
FAULT INFORMATION Screen
166
INTERFACE Screen
167
Table 6-28: Available USER INTERFACE Screen Soft Keys
169
Table 6-29: Available USER INTERFACE Screen Soft Keys
170
Table 6-30: Available ETHERNET INTERFACE SETUP Screen Soft Keys
172
Table 6-31: Available SERIAL INTERFACE SETUP Screen Soft Keys
173
Table 6-32: Available USB INTERFACE SETUP Screen Soft Keys
174
Table 6-33: Available GPIB INTERFACE SETUP Screen Soft Keys
175
UNIT INFORMATION Screen
178
PARALLEL UNITS Screen
179
SYSTEM SETTINGS Screen
180
EXTERNAL STORAGE MANAGEMENT Screen
181
CALIBRATION MENU Screen
182
FIRMWARE UPDATE Screen
183
REMOTE SUPPORT Screen
184
7 Rear Panel, Connectors and Protection
185
OUTPUT Terminals
185
Output Power Connector Rating and Isolation
186
Wire Size
186
Connecting a UUT
186
External Voltage Sense Input Terminals
187
External Voltage Sense Connector Rating and Isolation
188
Load Connection Without External Voltage Sense
188
Load Connection with External Voltage Sense
188
Auxiliary I/O
189
Auxiliary I/O Functions
189
DB25 Connector AUX I/O Pin Locations
190
I/O Signal Table by Pin Number
191
I/O Signal Table by Function
192
Dedicated Function Digital Inputs
193
Transient Trigger Input
194
External or Line Sync Input
195
Digital Output Control Signals
198
User Programmable Digital Signals
201
Analog I/O Descriptions
203
DC Power Supply
205
RS232 Description
205
Front Panel Operation of AUX I/O Functions
206
System Interface Bus Connectors
213
8 Remote Control Programming
214
Overview
214
Programming Conventions and Notations
214
Command Terminators
215
Remote Control Command Descriptions by Subsystem
216
Calibration Commands
217
AFX Calibration Commands
217
UPC Mode Specific Commands
219
AUX I/O Interface Calibration Commands
219
Measurement Commands
220
Voltage Measurement Commands
220
Frequency Measurement Commands
221
Current Measurement Commands
221
Power Measurement Commands
223
Kwh Measurement Commands
223
Other Measurement Commands
225
Measurement Data Logging Commands
225
Waveform Capture Commands
229
Harmonic Measurements Commands
231
Output Control Commands
236
Program Commands
240
Program Control Commands
240
Execution Commands
251
Transient Segments Commands
252
Memory Management Commands
257
Source Commands
260
Source Configuration Programming Commands
260
Voltage Programming Commands
265
Frequency Programming Commands
272
Current Programming Commands
274
Phase Programming Commands
276
Waveform Programming Commands
278
Voltage Protection Programming Commands
286
Current Protection Programming Commands
288
Power Protection Programming Commands
292
Impedance Programming Commands
298
STEP Transient Commands
301
PULSE Transient Commands
321
IEC413 Option Interharmonics Commands
332
Status Commands
336
System Commands
338
System Error Commands
338
System Information Commands
339
System Interface Commands
342
System Configuration Commands
346
Parallel System Commands
348
System Sanitization Commands
349
Communication LAN Commands
349
Communication Serial Port Commands
354
Communication USB Commands
356
Communication GPIB Commands
357
System Firmware Commands
359
System Remote Access Commands
360
Miscellaneous System Commands
362
Auxiliary I/O System Commands
363
System Analog & Digital IO Commands
363
Source:synchronize Commands
376
Program:transient Triggers Commands
379
AUX I/O Calibration Commands
381
IEEE488.2 Common Commands
385
Status and Events Registers
388
Status Byte Register (STB)
388
Status Event Register (ESR)
391
SCPI Status Registers
392
9 USB Driver Installation
394
Overview
394
Installation
394
10 LAN Interface Configuration
396
Overview
396
Web Browser Interface
396
Access Control
398
Browser Access Control
399
Front Panel Access Control
402
Web Browser Interface
403
Available Web Interface Menu Tree
403
Home Screen
404
SCPI Console Command Line Interface
404
Status Byte Display
405
Browser Status Bar
405
Operation Manual PDF
405
Source Control Screens
406
Program
407
Protections
408
Transients
409
Program Memory
415
Waveform
416
Waveform Editor
417
SCPI Script
420
Measurement Screens
422
Monitor
423
Real-Time Plot
424
Plot
425
Data Logger
426
Scope
427
Harmonics
429
Configuration Screens
430
Unit Settings
431
User Limits & Presets
432
Ramp Time & Slew Rate
433
System Screens
434
Error/Event Queue
435
Fault List
436
Error/Event List
437
Interface Setup
438
Access Control
439
Digital & Analog Io's
440
Unit Information
444
Parallel Units
445
Memory Browser
446
Calibration
447
Remote Support
448
Import / Export
448
Firmware Update
449
Sanitize and Reboot
450
Additional Functions
450
Sharing Options - FTP & SAMBA
450
11 Calibration
451
Calibration Interval
451
Closed Case User Calibration
451
Equipment Required
451
Calibration Procedures
452
Voltage Calibration - Offset
452
Current Calibration - Offset
453
Voltage Calibration - Gain
454
Current Gain Calibration Setup Diagrams
455
Current Calibration Load Values
456
Current Calibration - Gain
457
Exit Calibration Mode
457
12 Warnings & Error Messages
458
Preface
458
Service and Maintenance
479
Warnings
479
Authorized Service Centers
480
14 CE MARK Declaration of Conformity
481
Index
482
Advertisement
Advertisement
Related Products
Pacific Power Source 390AFX
Pacific Power Source 3120AFX
Pacific Power Source 3150AFX
Pacific Power Source 3180AFX
Pacific Power Source 3240AFX
Pacific Power Source 3300AFX
Pacific Power Source 3450AFX
Pacific Power Source 3600AFX
Pacific Power Source 3750AFX
Pacific Power Source 31500AFX
Pacific Power Source Categories
AC Power Distribution
Controller
Portable Generator
UPS
Switch
More Pacific Power Source Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL