Sign In
Upload
Manuals
Brands
Olympus Manuals
Medical Equipment
EVIS EXERA III
Olympus EVIS EXERA III Manuals
Manuals and User Guides for Olympus EVIS EXERA III. We have
3
Olympus EVIS EXERA III manuals available for free PDF download: Instructions Manual, Manual
Olympus EVIS EXERA III Instructions Manual (130 pages)
Brand:
Olympus
| Category:
Medical Equipment
| Size: 5.99 MB
Table of Contents
Table of Contents
3
Labels and Symbols
7
Applicability of Endoscopy and Endoscopic Treatment
9
Important Information - Please Read before Use
9
Instruction Manual
9
Intended Use
9
User Qualifications
11
Instrument Compatibility
12
Repair and Modification
12
Signal Words
12
Dangers, Warnings, and Cautions
13
Cardiac Applications
17
Summary of the Equipment Functions
18
Chapter 1 Checking the Package Contents
21
Checking the Package Contents List
21
Chapter 2 Nomenclature and Functions
23
Nomenclature and Functions
23
2.2 Front Panel
25
2.3 Rear and Side Panels
30
Chapter 3 Installation and Connection
33
Precautions for Installation and Connection
33
Installation Workflow
34
Installation of Equipment
35
Installation on the Mobile Workstation (WM-NP2, WM-DP2, WM-NP1, WM-WP1, or WM-DP1)
36
Installation in Another Location
38
Installation of the Water Container
39
Selection of the Lamp Ignition Mode
39
Manual Ignition (MANU)
40
Automatic Ignition (AUTO)
40
Connection of the Video System Center
41
Connection of the Foot Switch
44
Connection to the AC Mains Power Supply
45
Chapter 4 Inspection
47
Precautions for Inspection
47
Inspection Workflow
48
Checking the Lamp Ignition Mode
49
Connection of an Endoscope
49
Inspection of the Power Supply
52
Checking the Lamp Usage Indicator
54
Inspection of the Examination Light
54
Inspection of the Brightness Mode Selection Function
56
Inspection of Brightness Adjustment
57
Inspection of Automatic Brightness Adjustment
57
Inspection of Manual Brightness Adjustment
60
Inspection of the Optical-Digital Observation Function
62
4.11 Inspection of the Transillumination Function
64
4.12 Inspection of the High Intensity Mode
65
4.13 Inspection of Air and Water Feeding
68
4.14 after Inspection
70
Chapter 5 Operation
71
Attention to Operation
71
Operation Workflow
74
Turning the Light Source on and Igniting the Examination Lamp
75
Setting the Brightness Mode
76
Brightness Adjustment
77
Automatic Brightness Adjustment
77
Manual Brightness Adjustment
79
Optical-Digital Observation
80
Transillumination Function
82
High Intensity Mode
83
Air/Water Feeding
84
5.10 Extinguishing the Examination Lamp
85
5.11 Turning the Light Source off
86
Chapter 6 Lamp Replacement
87
Replacement of the Examination (Xenon) Lamp
87
Removal of the Lamp
88
Insertion of the Lamp
92
Lamp Usage Indicator Reset
97
Instruction Manual
98
Chapter 7 Reprocessing, Storage, Disposal, and Transportation
99
Reprocessing
99
Surface Disinfectant Cleaner
101
Signs of Degradation from Reprocessing
102
Preparing Equipment for Reprocessing
103
Equipment Needed
103
Reprocessing the Light Source and Accessories
104
Storage
107
Disposal
107
Transportation
107
Chapter 8 Troubleshooting
109
Troubleshooting
109
Troubleshooting Guide
109
Returning the Light Source for Repair
114
Appendix
115
Combination Equipment
115
System Chart
115
Water Container
118
Transportation, Storage, and Operating Environments
119
Specifications
119
EMC Information
123
Advertisement
Olympus EVIS EXERA III Instructions Manual (104 pages)
BRONCHOVIDEOSCOPE
Brand:
Olympus
| Category:
Medical Equipment
| Size: 4.38 MB
Table of Contents
Table of Contents
3
Symbols
7
Important Information - Please Read before Use
8
Intended Use
8
Applicability of Endoscopy and Endoscopic Treatment
8
Instruction Manual
9
User Qualifications
9
Instrument Compatibility
10
Reprocessing before the First Use/Reprocessing and Storage after Use
10
Spare Equipment
10
Maintenance Management
10
Prohibition of Improper Repair and Modification
11
Signal Words
11
Warnings and Cautions
12
Warnings and Cautions: Disappeared or Frozen Endoscopic Image
17
Examples of Inappropriate Handling
18
Chapter 1 Checking the Package Contents
19
Checking the Package Contents
19
Packaged Items for the Americas, Europe, Australasia, Middle East, and Africa
20
Packaged Items for Countries Other than the Americas, Europe, Australasia, Middle East, and Africa
21
Chapter 2 Instrument Nomenclature and Specifications
23
Nomenclature and Functions
23
Control Section, Insertion Section
24
Endoscope Connector
27
Specifications
28
Environment
28
Specifications
29
Chapter 3 Preparation and Inspection
33
The Workflow of Preparation and Inspection
33
Preparation of the Equipment
35
Inspection of the Endoscope
36
Inspection of the Bending Mechanism
39
Inspection of the Insertion Tube Rotation Mechanism
41
Inspection of Accessories
42
Inspection of the Suction Valve (MAJ-207) or Single Use Suction Valve (MAJ-209)
42
Inspection of the Biopsy Valve (MD-495)
43
Inspection of the Single Use Biopsy Valve (MAJ-210)
44
Inspection of the Mouthpiece (MA-651)
45
Series OPERATION MANUAL
46
Attaching Accessories to the Endoscope
46
Attaching the Suction Valve (MAJ-207) or the Single Use Suction Valve (MAJ-209)
46
Attaching the Biopsy Valve (MD-495) or Single Use Biopsy Valve (MAJ-210)
47
Inspection of Ancillary Equipment
48
Connection of the Endoscope and Ancillary Equipment
48
Connection to the Light Source
48
Connection of the Suction Tube
49
Inspection of the Endoscopic System
50
Inspection Summary
50
Inspection of the Ancillary Equipment
50
Inspection of the Endoscopic Image
50
Inspection of the Remote Switches
52
Inspection of the Water Feeding Function
53
Inspection of the Suction Function
54
Inspection of the Instrument Channel
55
Chapter 4 Operation
57
Warnings and Cautions: Operation
57
Insertion
59
Holding and Manipulating the Endoscope
59
Insertion of the Endoscope
60
Observation of the Endoscopic Image
62
Angulation of the Distal End
62
Operation of the Insertion Tube Rotation
63
Feeding Fluids
64
Suction
65
Using Endotherapy Accessories
66
Insertion of Endotherapy Accessories into the Endoscope
67
Operation of Endotherapy Accessories
70
Withdrawal of Endotherapy Accessories
70
High-Frequency Cauterization Treatment
71
Argon Plasma Coagulation (APC)
73
Laser Cauterization
75
Ultrasonic Observation
76
Bronchoalveolar Lavage
77
Withdrawal of the Endoscope
78
Transportation of the Endoscope
79
Transporting Within the Hospital
79
Transporting Outside the Hospital
79
Chapter 5 Troubleshooting
81
Troubleshooting
81
Troubleshooting Guide
82
Image Quality or Brightness
82
Water Feeding
83
Suction
83
Endotherapy Accessories
84
Others
84
Withdrawal of the Endoscope with an Irregularity
85
Withdrawal When the WLI and NBI Endoscopic Images Appear on the Monitor
85
Withdrawal When Either the WLI or the NBI Endoscopic Image Does Not Appear on the Monitor
86
Withdrawal When no Endoscopic Image Appears on the Monitor or a Frozen Image Cannot be Restored
86
Returning the Endoscope for Repair
87
Appendix
89
Combination Equipment
89
System Chart
89
Reprocessing Equipment
91
Compatible Endotherapy Accessories
92
EMC Information
98
Olympus EVIS EXERA III Manual (62 pages)
Brand:
Olympus
| Category:
Medical Equipment
| Size: 20.62 MB
Advertisement
Advertisement
Related Products
Olympus EVIS EXERA II
Olympus ESG-300
Olympus EndoCapsule
Olympus EMPOWER EMP-H35S
Olympus EMPOWER EMP-H65S
Olympus EMPOWER EMP-H100S
Olympus ESG-410
Olympus VISERA ENF-V2
Olympus ENF-V3
Olympus E-519
Olympus Categories
Digital Camera
Voice Recorder
Microscope
Camera Accessories
Camera Lens
More Olympus Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL