National Instruments FlexDMM PXI-4070 Manuals
Manuals and User Guides for National Instruments FlexDMM PXI-4070. We have
1
National Instruments FlexDMM PXI-4070 manual available for free PDF download: Calibration Procedure
National Instruments FlexDMM PXI-4070 Calibration Procedure (68 pages)
6 1/2-Digit
Brand:
National Instruments
| Category:
Multimeter
| Size: 0.93 MB
Table of Contents
Calibration Procedure ni 4070/4072 6½-Digit Flexdmm
1
Table of Contents
1
Conventions
2
Software Requirements
2
Documentation Requirements
3
Calibration Function Reference
3
Password
3
Calibration Interval
3
Test Equipment
4
Test Conditions
5
Calibration Procedures
6
Initial Setup
6
Verification Procedures
7
Nidmm_Setattributevireal64 with the Following Parameters/Attribute_Id = Attribute_Value
8
Nidmm_Setattributevireal64 with the Following Parameters
8
Attribute_Id = Attribute_Value
8
Function
9
26. Set the Input Resistance of the ni 4070/4072 to >10 GΩ by Calling
10
Nidmm_Setattributevireal64
10
With the Following Parameters
10
Nidmm_Attr_Input_Resistance
10
Nidmm_Val_Greater_Than_10_Gigaohm
10
Nidmm_Val_Dc_Volts
10
Range
10
Resolution = 10E-6
10
Attribute_Value = NIDMM_VAL_10_MEGAOHM
11
34. Set the Input Resistance of the ni 4070/4072 to >10 GΩ by Calling
12
Call Nidmm_Read . Verify that this Measurement Falls between the
14
58. Set the Input Resistance of the ni 4070/4072 to 10 MΩ by Calling
14
Nidmm_Setattributevireal64 with the Following Parameters
14
Attribute_Value
14
Call . Verify that this Measurement Falls between the Limits Listed in Table
14
Call Nidmm_Read . Verify that this Measurement Falls between the Limits Listed in Table
14
Range = 100
14
Resolution = 100E-6
14
Attribute_Id = Attribute_Value
14
Calibrator Binding Posts. Figure 1 Shows the Correct Connections
15
Attribute_Id = Attribute_Value
37
Adjustment Procedures
39
Call Nidmm_Configuremeasurement with the Following Parameters: Function = NIDMM_VAL_DC_VOLTS
15
Range = 300
15
Resolution = 300E-6
15
Call Nidmm_Read . Verify that this Measurement Falls between the Limits Listed in Table
15
Fasten the Connectors on One End of the Fluke 5440 Cable to the
15
Reset the Calibrator
15
Verification Limits
58
DC Voltage
58
AC Voltage
59
4-Wire Resistance
60
2-Wire Resistance
61
DC Current
61
AC Current
62
Frequency
62
Capacitance and Inductance
63
Appendix A: Calibration Options
64
Where to Go for Support
68
Advertisement
Advertisement
Related Products
National Instruments FlexDMM PCI-4070
National Instruments FlexDMM PXI-4072
National Instruments FlexDMM PXI-4071
National Instruments FlexRIO PXIe-7961R
National Instruments FieldPoint FP-PS-4
National Instruments QuickSyn FSW-0010, QuickSyn FSW-0020
National Instruments FELDPoint FP-2000
National Instruments FW-7344
National Instruments FieldPoint FP-DO-410
National Instruments FP-TC-120
National Instruments Categories
Control Unit
I/O Systems
Controller
Computer Hardware
Measuring Instruments
More National Instruments Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL