Sign In
Upload
Manuals
Brands
Megger Manuals
Measuring Instruments
MIT2500
User Manuals: Megger MIT2500 Insulation Tester
Manuals and User Guides for Megger MIT2500 Insulation Tester. We have
4
Megger MIT2500 Insulation Tester manuals available for free PDF download: User Manual, Quick Start Manual
Megger MIT2500 User Manual (45 pages)
MIT400/2 Series Insulation and continuity testers
Brand:
Megger
| Category:
Measuring Instruments
| Size: 4.48 MB
Table of Contents
Table of Contents
2
1 Introduction
3
2 G Safety Warnings
4
Symbols Used on the Instrument
4
WEEE Directive
5
Battery Disposal
5
3 General Description
6
Unpacking the Carton
6
Carton Contents (All Instruments)
6
4 Preparations for Use (All Instruments)
7
Batteries
7
Preliminary Test Lead Check
7
5 Instrument Overview
8
General Functions
8
Display Contents
9
Terminal Overview
10
6 General Operating Instructions
11
7 Input Terminals
12
Terminal Test Lead Connections
12
Terminal + Guard (MIT2500)
12
Terminal Test Lead Connection
13
SP5 Switched Probe (Not MIT400/2)
15
8 AC/DC Voltage and Frequency Measurements
16
For 2 Terminal Instruments and MIT2500
16
For 3 Terminal Instruments (MIT481/2, MIT485/2 Only)
17
Result Storage
18
9 Insulation Resistance Testing
19
Measurement for 2 Terminal Instruments and MIT2500
19
Variable Voltage Insulation Testing (MIT430/2, MIT485/2, MIT2500)
22
Polarisation Index (PI) and Dielectric Absorption Ratio (DAR)
22
For 3 Terminal Instruments (MIT481/2, MIT485/2 Only)
25
ESD Testing Mode
26
Mit400Esd)
26
REN Mode
27
10 Continuity Testing [Ω]
28
Measurement for 2 Terminal Instruments and MIT2500
28
Single or Bi-Directional Testing
29
Test Lead Null
29
Buzzer PASS/FAIL Threshold
30
Buzzer ON/OFF
30
PASS / FAIL Limit Alarm
30
Test Current - 20 Ma / 200 Ma
30
Measurement for 3 Terminal Instruments
30
Visual Fast Continuity (Silent Buzzer) Mode
31
REL Mode
31
11 Capacitance Measurements
32
Capacitance Measurement Procedure (2 Terminals)
32
Distance Measurement by Capacitance
32
Capacitance Measurement Procedure (3 Terminals)
32
12 Saving, Recalling and Downloading Test Results
33
Saving Test Results
33
Test Results Recall
34
PI and DAR Recall
34
Deleting Test Results
35
Downloading Test Results
35
Procedure for Pairing Your mit to the PC
35
Downloading Data to the PC
36
13 SETUP Configuration Options
38
14 Specification
39
15 Battery and Fuse Replacement
41
Battery Condition and Replacement
41
Procedure to Replace Batteries
41
Blown Fuse Indicator
42
Fuse Replacement Procedure
42
Preventive Maintenance
42
16 Repair and Warranty
43
Calibration, Service and Spare Parts
43
Advertisement
Megger MIT2500 User Manual (47 pages)
Insulation and continuity testers
Brand:
Megger
| Category:
Measuring Instruments
| Size: 3.85 MB
Table of Contents
Table of Contents
4
1 Introduction
5
2 G Safety Warnings
6
WEEE Directive
7
Battery Disposal
7
3 General Description
8
4 Preparations for Use (All Instruments)
9
Batteries
9
Preliminary Test Lead Check
9
5 Instrument Overview
10
General Functions
10
Display Contents
11
Terminal Overview
12
6 General Operating Instructions
13
7 Input Terminals
14
SP5 Switched Probe (Not MIT400/2)
17
8 AC/DC Voltage and Frequency Measurements
18
For 3 Terminal Instruments (MIT481/2, MIT485/2 Only)
19
Result Storage
20
9 Insulation Resistance Testing
21
Measurement for 2 Terminal Instruments and MIT2500
21
Variable Voltage Insulation Testing (MIT420/2, MIT430/2, MIT485/2, MIT2500)
24
Polarisation Index (PI) and Dielectric Absorption Ratio (DAR)
24
ESD Testing Mode
29
REN Mode
30
10 Continuity Testing Ω
31
Measurement for 2 Terminal Instruments and MIT2500
31
Single or Bi-Directional Testing
32
Test Lead Null
32
Buzzer PASS/FAIL Threshold
33
Buzzer ON/OFF
33
PASS / FAIL Limit Alarm
33
Test Current - 20 Ma / 200 Ma
33
Measurement for 3 Terminal Instruments
33
Visual Fast Continuity (Silent Buzzer) Mode
34
REL Mode
34
11 Capacitance Measurements
35
Capacitance Measurement Procedure
35
Distance Measurement by Capacitance
35
Capacitance Measurement Procedure (3 Terminals)
35
12 Saving, Recalling and Downloading Test Results
36
Saving Test Results
36
Test Results Recall
37
PI and DAR Recall
37
Deleting Test Results
38
Downloading Test Results
38
Procedure for Pairing Your mit to the PC
38
Downloading Data to the PC
39
13 SETUP Configuration Options
41
15 Battery and Fuse Replacement
44
Battery Condition and Replacement
44
Procedure to Replace Batteries
44
Blown Fuse Indicator
45
Fuse Replacement Procedure
45
Preventive Maintenance
45
16 Repair and Warranty
46
Calibration, Service and Spare Parts
46
Megger MIT2500 Quick Start Manual (6 pages)
Insulation Tester
Brand:
Megger
| Category:
Test Equipment
| Size: 0.95 MB
Table of Contents
Insulation Test Range – Press & Hold
2
Continuity Measurement from 0.01Ω to 999 Kω (Automatic)
2
Capacitance Measurement (Automatic)
2
Insulation Testing - Press and L to LOCK Test on
3
Press & HOLD to Start INSULATION Test
3
Selects AC-Trms or DC Mode
3
Buzzer ON/OFF – Not Warning Functions
4
Backlight ON/OFF
4
SETUP – Change Setup Value / after Test – SAVE Result
4
Insulation Testing – Measures REN Value During Insulation Test
5
Advertisement
Megger MIT2500 Quick Start Manual (8 pages)
Insulation Tester
Brand:
Megger
| Category:
Test Equipment
| Size: 1.53 MB
Advertisement
Related Products
Megger MIT400/2 Series
Megger MIT405/2
Megger MIT415/2
Megger MIT417/2
Megger MIT420/2
Megger MIT430/2
Megger MIT481/2
Megger MIT485/2
Megger MIT410/2
Megger MIT400/2-LG2
Megger Categories
Test Equipment
Measuring Instruments
Multimeter
Security Sensors
Receiver
More Megger Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL