Sign In
Upload
Manuals
Brands
Honeywell Manuals
Security System
VISTA-128BP
Honeywell VISTA-128BP Manuals
Manuals and User Guides for Honeywell VISTA-128BP. We have
3
Honeywell VISTA-128BP manuals available for free PDF download: Installation And Setup Manual, User Manual, Programming Manual
Honeywell VISTA-128BP Installation And Setup Manual (128 pages)
Commercial Burglary Partitioned Security Systems
Brand:
Honeywell
| Category:
Security System
| Size: 1.23 MB
Table of Contents
Table of Contents
3
List of Figures
5
Conventions Used in this Manual
6
SECTION 1: General Description
7
About the VISTA-128BP/VISTA-250BP
7
Features
8
SECTION 2: Partitioning and Panel Linking
11
Theory of Partitioning
11
Setting-Up a Partitioned System
11
Common Lobby Logic
11
Master Keypad Setup and Operation
13
Panel Linking
14
SECTION 3: Installing the Control
17
Mounting the Control Cabinet
17
Installing the Cabinet Lock
17
Grade a Mercantile Premises Listing Guidelines
17
Figure 3-1: Installing the Lock
17
Grade a Mercantile Safe and Vault Listing Guidelines
18
Installing the Control's Circuit Board
18
Figure 3-2: Cabinet Attack Resistance Considerations
18
Figure 3-3: Mounting the PC Board
18
Installing the Keypads
19
Figure 3-4: Keypad Connections to Control Panel
19
Figure 3-5: Using a Supplementary Power Supply
19
Installing External Sounders
20
Figure 3-6: Wiring Polarized Fire Devices
20
Telephone Line Connections
21
Figure 3-7: Wiring Nonpolarized Burglary Devices
21
Wiring Burglary, Panic and Smoke Detector Devices to Zones 1-9
22
Figure 3-8: Telephone Line Connections
22
Figure 3-10: 2-Wire Smoke Detector on Zone 1
23
Figure 3-11: 4-Wire Smoke Detectors
24
Figure 3-12A: Wiring a 333PRM to the Control
24
Figure 3-12B: Wiring a 333PRM Using a 4204
25
Figure 3-12C: Wiring a 333PRM Using a 4204 and a Power Supply
25
Figure 3-13: Wiring Latching Glassbreaks to Zone 8
26
Figure 3-14: Wiring a Normally Closed Loop for Tamper Supervision
26
Figure 3-15: Wiring a Normally Open Loop for Tamper Supervision
26
Installing RPM Devices
27
Figure 3-16: Polling Loop Connections to the VISTA-128BP/VISTA-250BP
28
Wireless Zone Expansion
29
Figure 3-17: Polling Loop Connections Using One 4297 Extender Module
29
Figure 3-18: Polling Loop Connections Using Multiple Extender Modules
29
Figure 3-19: Installing the 5881ENHC with Tamper Protection
30
Figure 3-20: 5881 RF Receiver (Cover Removed)
31
Installing Output Devices
33
Figure 3-21: 4204 Relay Module
33
Figure 3-22: 4204CF Relay Module
33
Installing the Ground Start Module
34
Figure 3-23: Wiring the FSA Module
34
Installing a Remote Keyswitch
35
Figure 3-24: Ground Start Module Connections
35
Smoke Detector Reset
36
Remote Keypad Sounder
36
Figure 3-25: Remote Keyswitch Wiring
36
Figure 3-26: Remote Keypad Sounder Wiring
36
Installing the VA8200 Panel Link Module
37
Figure 3-27: Panel Linking Block Diagram
37
Figure 3-28: VA8200 Panel Link Module Wiring
37
Long Range Radio Connected to the J7 Triggers
38
Long Range Radio Connected to the ECP
38
Installing the Alpha Pager Module
39
Figure 3-29: Wiring Long Range Radio to Keypad Terminals
39
Access Control Using Vistakey
41
Figure 3-30: Wiring the Alpha Pager Module
41
Access Control Using the Passpoint Access Control System
42
Figure 3-31: Wiring the Vistakey
42
Installing a 4100SM
43
Figure 3-32: Wiring the VISTA Gateway Module
43
Figure 3-33: 4100SM Using a Serial Printer
43
Installing the 4285/4286 VIP Module
44
Figure 3-34: 4100SM Using Home Automation
44
Figure 3-35: VIP Module Connections
45
Installing the Audio Alarm Verification Module
46
Installing Telesmart
47
Figure 3-36: UVS Connections to the Control Panel
47
Figure 3-37: Telesmart Phone Connections
49
Figure 3-38: Telesmart Speaker Connection
49
Figure 3-39: Keypad Connections
50
Figure 3-40: RTC and Ground Connections
50
Figure 3-41: Telesmart to Control Connections
50
Connecting the Transformer
51
Figure 3-42: 1361 Transformer and Battery Connections
51
Figure 3-43: 1361X10 Transformer Connections
51
Panel Earth Ground Connections
52
Determining the Control's Power Supply Load
52
Determining the Size of the Standby Battery
53
SECTION 4: Programming
55
Program Modes
55
Entering and Exiting Programming Mode
55
Data Field Programming Mode
55
#93 Menu Mode Programming
56
Main Menu Options
57
Zone Number Designations
58
Zone Response Type Definitions
60
Zone Input Type Definitions
61
Programming for Panel Linking
62
Programming for the Alpha Pager Module
62
Programming for 4100SM
63
Programming for Access Control
63
Programming for ECP Long Range Radio
64
Programming for Telesmart
64
SECTION 5: Data Field Descriptions
65
About Data Field Programming
65
Programming Data Fields
65
Ignore Expansion Zone Tamper
67
Intelligent Test Report
67
Test Report Interval
67
SECTION 6: Scheduling Options
83
Time Window Definitions
84
Open/Close Schedules Definitions
85
Scheduling Menu Mode
86
Time Windows
87
Daily Open/Close Schedules
88
Holiday Schedules
88
Time-Driven Events
89
Limitation of Access Schedules
93
Temporary Schedules
94
User Scheduling Menu Mode
96
SECTION 7: Downloading Primer
97
General Information
97
Unattended Download
97
Getting On-Line with a Control Panel
99
Scheduled Download
100
Direct-Wire Downloading
100
Telco Handoff
100
Figure 7-1: Direct-Wire Downloading Connections
100
SECTION 8: Setting the Real-Time Clock
101
General Information
101
Setting the Time and Date
101
SECTION 9: User Access Codes
103
General Information
103
User Codes & Levels of Authority
103
Multiple Partition Access
104
Adding a Master, Manager, or Operator Code
105
Changing a Master, Manager, or Operator Code
106
Adding an RF Key to an Existing User
106
Deleting a Master, Manager, or Operator Code
106
Exiting the User Edit Mode
106
SECTION 10: Testing the System
107
Battery Test
107
Dialer Test
107
Burglary Walk-Test (Code + [5] TEST)
107
Armed Burglary System Test
107
Testing Wireless Transmitters
108
Trouble Conditions
109
To the Installer
109
APPENDIX A: Regulatory Agency Statements
111
UL Installation Requirements
111
UL609 Grade a Local Mercantile Premises/Local Mercantile Safe & Vault
111
UL365 Police Station Connected Burglar Alarm
111
UL611/UL1610 Central Station Burglary Alarm
112
California State Fire Marshal (CSFM) and UL Residential Fire Battery Backup Requirements
112
APPENDIX B: Summary of System Commands
115
APPENDIX C: Specifications
117
APPENDIX D: Contact ID and Pager Event Codes
119
Table of Contact ID Event Codes
119
Event Log and Pager Alpha Descriptors
119
Index
121
Advertisement
Honeywell VISTA-128BP User Manual (80 pages)
Commercial Burglary Partitioned Security System with Scheduling
Brand:
Honeywell
| Category:
Security System
| Size: 1.11 MB
Table of Contents
Table of Contents
3
System Overview
5
General
5
A Partitioned System
6
Panel Linking
6
Zones
6
Fire Protection
6
Burglary Protection
7
Alarms
7
Memory of Alarm
7
Speed Key (Macros)
8
Using Schedules
8
Device Timers
8
To Access Another Partition (GOTO Command)
8
Master Keypad Operation
9
Self-Help Feature
9
Phone Access & Voice Response Capability
9
About the Keypads
10
General
10
The Alpha Keypad
10
Functions of the Keypad
11
Entry/Exit Delays
14
General Information
14
Security Codes & Authority Levels
15
General Information
15
Duress Code
15
Quick Arming
15
Authority Levels
16
General Rules on Authority Levels and Changes
17
To Exit User Edit Mode
17
To Add a User
18
To Change a User's Code
20
To Delete a User
21
Accessing Other Partitions
22
To Access Another Partition
22
Global Arming
22
Master Keypad Operation
23
Common Lobby Operation
25
How User Codes Affect the Common Lobby
26
Accessing Other Panels
27
Single-Partition Single-Panel Mode
27
Multi-Partition Multi-Panel Mode
28
Multi-Panel View Mode
29
Priority of Displays for Multi-Partition and Multi-Panel Modes
30
Checking for Open Zones
31
Using the ✳ READY Key
31
Displaying All Zone Descriptors
32
Using the ✳ READY Key
32
Bypassing Protection Zones
33
Using the 6 BYPASS Key
33
Quick Bypass
34
Displaying Bypassed Zones
34
Group Bypass
35
Arming Perimeter Only
36
Using the 3 STAY Key
36
Auto-STAY Arming
37
Arming Perimeter Only
38
Using the 7 INSTANT Key
38
Arming All Protection
39
Using the 2 AWAY Key
39
Arming All Protection
40
Using the 4 MAXIMUM Key
40
Quick Exit
41
Using the # + 9 Keys
41
Disarming and Silencing Alarms
42
Using the 1 off Key
42
Memory of Alarm
42
Using the Keyswitch
43
General
43
Arming
43
Disarming
43
Chime Mode
44
Using the 9 Key
44
Messages
45
General Information
45
Panic Keys
46
Using Panic Keys
46
Speed Key (Macros)
47
General Information
47
Defining
47
Executing
48
Access Door Control
49
General Information
49
Executing
49
Using #70 Relay Menu Mode
50
General Information
50
Using Schedules
51
Delaying the Closing Time
51
Temporary Open/Close Schedules
51
Programming Temporary Schedules
52
Programming Device Timers
54
General Information
54
Randomize Output Device Times
56
Using #77 Instant Activation Mode
57
Event Log Procedures
60
General Information
60
To Display the Event Log
60
Setting the Time and Date
61
Testing the System
62
Using the 5 TEST Key
62
Testing Your System
62
Fire Alarm System
63
In Case of Fire Alarm
63
Silencing a Fire Alarm
63
Fire Display Lock
63
Typical Trouble Displays
64
Power Failure
65
Recommendations for Smoke and Heat Detectors
66
Recommendations for Proper Intrusion Protection
67
Emergency Evacuation
68
Maintenance
69
Replacing Batteries in Wireless Sensors
69
Taking Care of Your System
69
Routine Care
70
Silencing Low Battery Warning Tones at the Keypad
70
Maintaining Your System
69
Quick Guide to System Functions
71
Quick Guide to System Functions
72
Summary of Audible Notification
73
Index
78
Honeywell VISTA-128BP Programming Manual (36 pages)
2-Partitioned security system
Brand:
Honeywell
| Category:
Security System
| Size: 0.34 MB
Table of Contents
Table of Contents
2
Recommended Programming Procedure
3
Program Field Index
4
VISTA-40 Programming Form
5
Partition-Specific Fields
9
Programming with #93 Menu Mode
10
Zone Programming
11
5800 Series Transmitters Loop Designations
13
Expert Mode Zone Programming
14
Alpha Descriptors Programming
17
Alpha Descriptor Vocabulary
20
Device Programming
21
Relay Programming
22
Relay Voice Descriptors
25
Relay Voice Descriptors and Custom Word Substitutes Vocabulary
26
Custom Word Substitutes for VIP Module Annunciation
26
System Layout Worksheets
27
Relay Outputs Worksheets
33
VISTA-40 Summary of Connections Diagram
35
Advertisement
Advertisement
Related Products
Honeywell VISTA-128FBP
Honeywell Ademco VISTA-128FB
Honeywell VISTA-128SIA
Honeywell VISTA-128BPTSIA
Honeywell VISTA-128BPT
Honeywell VISTA-128FBPT
Honeywell VISTA-128FBPN
Honeywell VISTA-128BPEN
Honeywell ADEMCO VISTA-12A
Honeywell ADEMCO Vista-12C
Honeywell Categories
Thermostat
Controller
Control Unit
Security Camera
Accessories
More Honeywell Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL