Sign In
Upload
Manuals
Brands
Gossen MetraWatt Manuals
Measuring Instruments
PROFITEST MBASE MTECH
Gossen MetraWatt PROFITEST MBASE MTECH Manuals
Manuals and User Guides for Gossen MetraWatt PROFITEST MBASE MTECH. We have
2
Gossen MetraWatt PROFITEST MBASE MTECH manuals available for free PDF download: Operating Instructions Manual, Short-Form Operating Instructions
Gossen MetraWatt PROFITEST MBASE MTECH Operating Instructions Manual (64 pages)
Test Instruments for IEC 60364.6 / DIN VDE 0100
Brand:
Gossen MetraWatt
| Category:
Measuring Instruments
| Size: 1.42 MB
Table of Contents
Display Panel
3
1 Scope of Delivery
4
Table of Contents
4
2 Application
5
Overview of Features Included with Different PROFITEST ASTER Variants
5
Master
5
Using Cable Sets and Test Probes
5
Battery Test
6
Charging the Batteries in the Tester
6
3 Safety Features and Precautions
6
Switching the Instrument on and off
6
Device Settings
7
Automatic Settings, Monitoring and Shut-Off
10
Connecting the Instrument
10
4 Initial Start-Up
6
Installing or Replacing Rechargeable Batteries
6
Preparation for Use
6
5 General Instructions
10
Measurement Value Display and Memory
10
Testing Earthing Contact Sockets for Correct Connection
10
Help Function
11
Setting Parameters or Limit Values Using RCD Measurement as an Example
11
New! Freely Adjustable Parameters or Limit Values
12
New! Two-Pole Measurement with Rapid or
12
Semiautomatic Polarity Reversal
12
As Well as N and PE
13
(U N-PE ) for Country-Specific Plug Insert, E.g. SCHUKO
13
6 Measuring Alternating Voltage and Frequency
13
Single Phase Measurement
13
Voltage between L - PE, N - PE and L - L for Connection of 2-Pole Adapter
13
Voltage between L and N
13
L-N ), L and PE
13
3-Phase Measurement (Line-To-Line Voltage) and Phase Sequence
14
7 Testing Rcds
14
Measuring Contact Voltage
15
Nominal Residual Current
15
Special Testing for Systems and Rccbs
17
Testing Systems and Rccbs with Rising Residual Current (Alternating Current) for Rcds Type A, AC and B
17
Testing Systems and Rccbs with Rising Residual Current (Direct Current) for Rcds Type B
17
Testing Rccbs Which Are Suited for Pulsating DC Residual Current
18
Testing RCCBS with 5 I
18
7.3.1 Systems with Type RCD-S Selective Rcds
19
7.3.2 Prcds with Non-Linear Type PRCD-K Elements
19
Testing for Special Rcds
19
Srcds, PRCD-S (SCHUKOMAT, SIDOS or Comparable)
20
7.3.4 Type G or R Rccbs
21
Testing Residual Current Circuit Breakers (Rcds) in IT Systems with High Wiring Capacitance (E.g. in Norway)
22
Testing Residual Current Circuit Breakers in TN-S Systems
22
And I K )
23
8 Testing of Breaking Requirements Overcurrent Protective Devices, Measurement of Loop Impedance and Determination of Short-Circuit Current
23
Measurement with Positive Half-Waves (Only PROFITEST MTECH )
24
Measurements with Suppression of RCD Tripping
24
Evaluation of Measured Values
25
9 Measuring Line Impedance (Z L-N Function)
25
10 Earthing Resistance Measurement
27
Earthing Resistance Measurement (Function R )
27
Measuring with Probe
28
Measuring Without Probe
29
Measuring Earth Electrode Potential (Function U E )
30
Selective Earth Resistance Measurement with Accessory Current Clamp Sensor
31
11 Measuring the Impedance of Insulating Floors and Walls (Standing Surface Insulation Impedance ZST )
33
General
34
12 Measuring Insulation Resistance
34
Special Case: Earth Leakage Resistance (REINS )
36
13 Testing Meter Start-Up with Earthing Contact Adapter
37
14 Measuring Low-Value Resistance of up to 100 Ohm (Protective Conductors and Protective Equipotential Bonding Conductors)
38
15 Measurement with Accessory Sensors
40
Measuring Current with a Current Sensor Clamp
40
Creating a Distributor Structure in the Test Instrument
41
Creating Distributor Structures, General
41
16 Database
41
Transferring Distributor Structures
41
Structure Creation (Example for Electrical Circuit)
42
16.3.2 Searching for Structural Elements
43
Data Storage and Reporting
44
16.4.1 Using Barcode and RFID Readers
45
17 Operating and Display Elements
46
18 Characteristic Values
48
LED Indications, Mains Connections and Potential Differences
51
Charging Procedure with the Z502P Charger (Accessory)
56
Firmware Revision and Calibration Information
56
Fuses
56
Housing
56
19 Maintenance
56
Rechargeable Battery Operation and Charging
56
20 Appendix
57
Tables for the Determination of Maximum or Minimum Display Values under Consideration of Maximum Instrument Operating Uncertainty
57
Testing Electrical Machinery Per DIN en 60204 - Applications, Limit Values
59
Limit Values for Electrical Systems and Equipment
60
Periodic Testing Per BGV A3
60
List of Abbreviations and Their Meanings
61
Index
62
20.6.1 Internet Addresses for Additional Information
63
Bibliography
63
DKD Calibration Certificate
64
21 Repair and Replacement Parts Service Calibration Center and Rental Instrument Service
64
22 Recalibration
64
23 Product Support
64
Advertisement
Gossen MetraWatt PROFITEST MBASE MTECH Short-Form Operating Instructions (20 pages)
Brand:
Gossen MetraWatt
| Category:
Test Equipment
| Size: 0.65 MB
Advertisement
Related Products
Gossen MetraWatt PROFITEST Series
Gossen MetraWatt PROFITEST PV
Gossen MetraWatt PROFITEST Master IQ Series
Gossen MetraWatt PROFITEST MTECH+ IQ
Gossen MetraWatt PROFITEST MPRO IQ
Gossen MetraWatt PROFITEST MXTRA IQ
Gossen MetraWatt PROFITEST MF XTRA LEMONGREEN
Gossen MetraWatt PROFISIX
Gossen MetraWatt Multi Pro
Gossen MetraWatt PROFITEST PV 1500
Gossen MetraWatt Categories
Measuring Instruments
Test Equipment
Multimeter
Adapter
Controller
More Gossen MetraWatt Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL