Sign In
Upload
Manuals
Brands
Fujitsu Manuals
Server
Primergy BX920 S4
Fujitsu Primergy BX920 S4 Manuals
Manuals and User Guides for Fujitsu Primergy BX920 S4. We have
2
Fujitsu Primergy BX920 S4 manuals available for free PDF download: Upgrade And Maintenance Manual, Operating Manual
Fujitsu Primergy BX920 S4 Upgrade And Maintenance Manual (266 pages)
PRIMERGY BX920 S4 Server Blade Upgrade and Maintenance Manual
Brand:
Fujitsu
| Category:
Server
| Size: 7.31 MB
Table of Contents
Server Blade
1
Copyright and Trademarks
2
Table of Contents
7
Version History
17
1 Introduction
19
Notational Conventions
20
2 Before You Start
21
Classification of Procedures
23
Customer Replaceable Units (CRU)
23
Upgrade and Repair Units (URU)
24
Field Replaceable Units (FRU)
25
Average Task Duration
26
Tools You Need at Hand
27
Documents You Need at Hand
28
3 Important Information
31
Safety Instructions
31
CE Conformity
38
FCC Class a Compliance Statement
39
Environmental Protection
40
4 Basic Hardware Procedures
43
Using Diagnostics Information
43
Accessing the Management Blade Web Interface
43
Locating the Defective Server Blade
45
Determining the Error Class
46
Global Error Indicator
47
Customer Self Service (CSS) Indicator
48
Locating the Defective Component
49
Component Leds
50
Opening the Rack Door
52
Opening the Rack Door of a PRIMECENTER Rack
52
Opening the Rack Door of a PRIMECENTER M1 Rack
52
Shutting down the Server Blade
53
Removing a Server Blade
54
Preliminary Steps
54
Removing the Server Blade from the System Unit
55
Opening the Server Blade
56
Closing the Server Blade
57
Installing the Server Blade in the System Unit
58
Switching on the Server Blade
60
Concluding Software Tasks
61
Closing the Rack Door
62
Closing the Rack Door of a PRIMECENTER Rack
62
Closing the Rack Door of a PRIMECENTER M1 Rack
62
5 Basic Software Procedures
63
Starting the Maintenance Task
63
Launching a Video Redirection to a Server Blade
63
Checking the Server Blade Status
63
Checking the Server Blade Status Via Management Blade Web Interface
63
Checking the Server Blade Status Via Irmc
64
Saving BIOS Settings
65
Saving Irmc Settings
65
Connecting Virtual Media to the Managed Server Blade
65
Disabling Bitlocker Functionality
66
Disabling Boot Watchdog Functionality
67
Viewing Boot Watchdog Settings
67
Configuring Boot Watchdog Settings
67
Verifying and Configuring the Backup Software Solution
69
Note on Server Maintenance in a Multipath I/O Environment
70
Note on Server Maintenance in a Multipath I/O Environment
71
Switching on the ID Indicator
74
Completing the Maintenance Task
75
Updating or Recovering the System Board BIOS and Irmc
75
Updating or Recovering the System Board BIOS
75
Updating or Recovering the Irmc
78
Restoring BIOS Settings
80
Restoring Irmc Settings
80
Updating Mezzanine Card Firmware
80
Enabling Option ROM Scan
82
Verifying and Configuring the Backup Software Solution
83
Resetting the Boot Retry Counter
84
Viewing the Boot Retry Counter
84
Enabling Boot Watchdog Functionality
86
Enabling Replaced Components in the System BIOS
87
Verifying the Memory Mode
87
Verifying the System Time Settings
88
Viewing and Clearing the System Event Log (SEL)
89
Viewing the SEL
89
Saving the SEL
90
Clearing the SEL
91
Updating the NIC Configuration File in a Linux Environment
91
Enabling Bitlocker Functionality
93
Performing a RAID Array Rebuild
94
Looking up Changed MAC / WWN Addresses
94
Looking up MAC Addresses
94
Looking up WWN Addresses
95
Using the Chassis ID Prom Tool
96
Configuring LAN Teaming
96
After Replacing / Upgrading LAN/CNA Controllers
96
After Replacing the Server Blade
97
Switching off the ID Indicator
97
6 Hard Disk Drives / Solid State Drives
99
Basic Information
101
General Equipping Rules
102
Installing a 2.5-Inch HDD/SSD Module
103
Required Tools
103
Preliminary Steps
103
Removing the 2.5-Inch Dummy Module
103
Installing the 2.5-Inch HDD/SSD Module
105
Concluding Steps
107
Removing a 2.5-Inch HDD/SSD Module
108
Required Tools
108
Preliminary Steps
108
Removing the 2.5-Inch HDD/SSD Module
109
Installing the 2.5-Inch Dummy Module
110
Concluding Steps
110
Replacing a 2.5-Inch HDD/SSD Module
111
Required Tools
111
Preliminary Steps
112
Removing the Defective 2.5-Inch HDD/SSD Module
112
Installing the New 2.5-Inch HDD/SSD Module
112
Concluding Steps
112
Replacing HDD/SSD Backplanes
113
Required Tools
113
Preliminary Steps
113
Removing the HDD/SSD Backplane
114
Installing the HDD/SSD Backplane
115
Concluding Steps
116
7 Expansion Cards and Backup Units
117
Mezzanine Cards
118
Basic Information
118
Installing Riser Cards
120
Removing Riser Cards
122
Population Rules for Mezzanine Cards
124
Expansion Cards and Backup Units
125
Installing Mezzanine Cards
130
Required Tools
130
Preliminary Steps
130
Installing a Mezzanine Card
131
Concluding Steps
135
Removing Mezzanine Cards
136
Required Tools
136
Preliminary Steps
136
Removing a Mezzanine Card
137
Concluding Steps
139
Replacing Mezzanine Cards
140
Required Tools
140
Preliminary Steps
140
Removing a Mezzanine Card
141
Installing a Mezzanine Card
141
Concluding Steps
141
SAS RAID HDD Module
143
Basic Information
143
Installing the SAS RAID HDD Module
144
Required Tools
144
Preliminary Steps
144
Installing the SAS RAID HDD Module
145
Concluding Steps
146
Removing the SAS RAID HDD Module
147
Required Tools
147
Preliminary Steps
147
Removing the SAS RAID HDD Module
148
Concluding Steps
148
Replacing the SAS RAID HDD Module
150
Required Tools
150
Preliminary Steps
150
Replacing the SAS RAID HDD Module
151
Concluding Steps
151
Installing the FBU (Flash Backup Unit)
152
Required Tools
152
Preliminary Steps
152
Installing the FBU
153
Concluding Steps
154
Removing the FBU (Flash Backup Unit)
155
Required Tools
155
Preliminary Steps
155
Removing the FBU
156
Concluding Steps
157
Replacing the FBU (Flash Backup Unit)
158
Required Tools
158
Preliminary Steps
158
Removing the FBU
159
Installing the FBU
160
Concluding Steps
161
Main Memory
163
Basic Information
164
Memory Sequence
164
Population Rules
164
Independant Channel Mode
166
Mirrored Channel Mode
167
Performance Channel Mode
168
Rank Sparing Mode (Single Rank (1R) and Dual Rank (2R) RDIMM Modules)
169
Rank Sparing Mode for Quad Rank (4R) and Octa Rank (8R) LRDIMM Modules (Minimizing Waste of Spare Memory)
170
Dummy DIMM Modules
171
Installing Memory Modules
172
Preliminary Steps
172
Required Tools
172
Installing a Memory Module
173
Concluding Steps
174
Preliminary Steps
175
Removing Memory Modules
175
Required Tools
175
Removing a Memory Module
176
Concluding Steps
177
Preliminary Steps
178
Replacing Memory Modules
178
Required Tools
178
Installing a Memory Module
179
Removing a Memory Module
179
Concluding Steps
180
Handling of Memory Air Cowls
181
Installing the Air Cowls
181
Removing the Air Cowls
182
9 Processors
183
Basic Information
184
Installing Processors
184
Required Tools
184
Preliminary Steps
185
Installing a Processor
186
Concluding Steps
190
Removing Processors
191
Required Tools
191
Preliminary Steps
191
Removing a Processor
193
Concluding Steps
197
Upgrading or Replacing Processors
198
Required Tools
198
Preliminary Steps
198
Upgrading or Replacing a Processor
199
Concluding Steps
199
Handling Processor Heat Sinks
201
Required Tools
201
Preliminary Steps
201
Installing Processor Heat Sinks
202
Preparing the Heat Sink and Processor
203
Installing the Heat Sink
204
Removing Processor Heat Sinks
206
Replacing Processor Heat Sinks
207
Removing the Processor Heat Sink
207
Applying Thermal Paste
207
Installing the Processor Heat Sink
207
Concluding Steps
207
Applying Thermal Paste
208
10 System Board Components
211
Replacing the CMOS Battery
211
Required Tools
212
Preliminary Steps
212
Removing the Battery
213
Installing the CMOS Battery
214
Concluding Steps
215
USB Flash Module (UFM)
216
Installing the UFM
216
Required Tools
216
Preliminary Steps
216
Installing the UFM
217
Concluding Steps
219
Software Configuration
219
Removing the UFM
220
Required Tools
220
Preliminary Steps
220
Removing the UFM
221
Concluding Steps
221
Replacing the UFM
222
Required Tools
222
Preliminary Steps
222
Removing the UFM
223
Re-Installing the UFM
223
Concluding Steps
225
Software Configuration
225
Trusted Platform Module (TPM)
226
Installing the TPM
226
Required Tools
226
Preliminary Steps
226
Installing the TPM
227
Concluding Steps
230
Removing the TPM
231
Required Tools
231
Preliminary Steps
232
Removing the TPM
233
Concluding Steps
234
Replacing the TPM
235
Required Tools
235
Preliminary Steps
236
Removing the TPM
236
Re-Installing the TPM
236
Concluding Steps
237
Onboard SAS Enabling Key
238
Required Tools
238
Preliminary Steps
238
Removing the Defective Onboard SAS Enabling Key
239
Installing the New Onboard SAS Enabling Key
240
Concluding Steps
241
Replacing the System Board
242
Required Tools
243
Preliminary Steps
244
Removing the System Board
245
Installing the System Board
247
Mounting the System Board
247
Swapping the Processor
248
Concluding Steps
249
11 Server Blade
251
Replacing the Server Blade
252
12 Appendix
255
Mechanical Overview
255
Server Blade Front
255
Server Blade Interior
256
Configuration Tables
257
Memory Configuration Table
257
Mezzanine Card Configuration Table
257
Connectors and Indicators
258
Connectors and Indicators on the System Board
258
Onboard Connectors
258
Onboard Settings
259
Onboard Indicators and Controls
260
Connectors and Indicators on the Front
262
Front Panel Connectors
262
Front Panel Indicators
263
Indicators on the Hot-Plug HDD/SSD Module
265
Minimum Startup Configuration
266
Advertisement
Fujitsu Primergy BX920 S4 Operating Manual (66 pages)
Brand:
Fujitsu
| Category:
Server blade
| Size: 0.82 MB
Table of Contents
Table of Contents
7
1 Introduction
9
Concept and Target Groups for this Manual
9
Documentation Overview
10
Notational Conventions
11
2 Functional Overview
13
Features
13
Server Specification
20
3 Installation Steps, Overview
25
4 Important Information
27
Safety Instructions
27
CE Conformity
33
FCC Class a Device
34
Transporting the Server Blade
34
Notes on Installation in the System Unit
34
Environmental Protection
35
5 Hardware Installation
37
Unpacking the Server Blade
38
Installing the Server Blade in the System Unit
38
Connecting Devices
42
Instructions for Connecting/Disconnecting Cables
43
6 Starting up and Operation
47
Control and Display Elements
47
Switching the Server Blade on and off
51
Configuring the Server Blade
52
Preparing for Local Installation
52
Preparation for Remote Installation to Use Advanced Video Redirection
53
Configuring the Onboard SAS/SATA Controller
55
Configuring the SAS/SATA RAID Controller
55
Configuring the Onboard CNA Controller
56
Configuring the Server and Installing the Operating System with the Serverview Installation Manager
56
Configuring the Server and Installing the Operating System Without Serverview Installation Manager
58
Cleaning the Server Blade
59
7 Property and Data Protection
61
BIOS Setup Security Functions
61
8 Troubleshooting and Tips
63
Server Switches Itself off
63
Screen Remains Blank
63
Flickering Stripes on Monitor Screen
64
No Screen Display or Display Drifts
65
Incorrect Date and Time
65
System will Not Boot
65
Hard Disk Drive Error Messages at System Boot
66
Added Drive Reported as Defective
66
Error Message on Screen
66
Advertisement
Related Products
Fujitsu PRIMERGY BX924 S3
Fujitsu PRIMERGY BX922 S2
Fujitsu PRIMERGY BX924 S2
Fujitsu PRIMERGY BX920 S2
Fujitsu Primergy BX920 S3
Fujitsu PRIMERGY BX924 S4
Fujitsu PRIMERGY BX920 S1
Fujitsu PRIMERGY BX960 S1
Fujitsu PRIMERGY BX900
Fujitsu Primergy BX900 S2
Fujitsu Categories
Air Conditioner
Laptop
Server
Scanner
Storage
More Fujitsu Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL