Sign In
Upload
Manuals
Brands
Emerson Manuals
Transmitter
Rosemount 644 with HART Protocol
Emerson Rosemount 644 with HART Protocol Manuals
Manuals and User Guides for Emerson Rosemount 644 with HART Protocol. We have
1
Emerson Rosemount 644 with HART Protocol manual available for free PDF download: Reference Manual
Emerson Rosemount 644 with HART Protocol Reference Manual (112 pages)
Temperature Transmitter
Brand:
Emerson
| Category:
Transmitter
| Size: 6.52 MB
Table of Contents
Table of Contents
3
Using this Manual
9
Transmitter Overview
10
Overview
11
Safety Messages
12
System Readiness
12
Confirm Correct Device Driver
13
Surges/Transients
13
Configuration Methods
13
Configuring on the Bench
13
Selecting a Configuration Tool
14
Setting the Loop to Manual
16
Failure Mode
16
HART Software Lock
17
Verify Configuration
17
Field Communicator
17
AMS Device Manager
18
Loi
18
Checking Transmitter Output
18
Basic Configuration of the Transmitter
19
Mapping the HART Variables
20
Configuring the Sensor(S)
21
Setting Output Units
22
Configure Dual Sensor Options
23
Differential Temperature Configuration
24
Average Temperature Configuration
25
Hot Backup Configuration
26
Sensor Drift Alert Configuration
28
Configure Device Outputs
29
Re-Range the Transmitter
29
Damping
30
Configure Alarm and Saturation Levels
32
Configuring the LCD Display
33
Inputting Device Information
35
Tag, Date, Descriptor and Message
35
Configure Measurement Filtering
36
50/60 Hz Filter
36
Resetting the Device
37
Intermittent Sensor Detection
37
Open Sensor Hold off
38
Diagnostics and Service
39
Performing a Loop Test
39
Simulate Digital Signal (Digital Loop Test)
39
Thermocouple Degradation Diagnostic
40
Minimum/Maximum Tracking Diagnostic
42
Establishing Multi Drop Communication
43
Changing a Transmitter Address
43
Using the Transmitter with the HART Tri-Loop
44
Set the Transmitter to Burst Mode
44
Set Process Variable Output Order
45
Transmitter Security
46
Available Security Options
46
Overview
49
Safety Messages
50
Considerations
50
General
50
Commissioning
50
Installation
50
Mechanical
51
Electrical
51
Environmental
51
Installation Procedures
52
Set the Alarm Switch
53
Mount the Transmitter
54
Install the Device
55
Multichannel Installations
59
LCD Display Installation
60
Rev SA July
62
Overview
63
Safety Messages
63
Wiring and Powering the Transmitter
63
Sensor Connections
64
Power the Transmitter
66
Ground the Transmitter
67
Wiring with a Rosemount 333 HART Tri-Loop (HART/4-20 Ma Only)
70
Overview
73
Safety Messages
73
Calibration Overview
74
Trimming
74
Sensor Input Trim
74
Application: Linear Offset (Single-Point Trim Solution)
75
Application: Linear Offset and Slope Correction (Two-Point Trim)
75
Recall Factory Trim-Sensor Trim
76
Active Calibrator and EMF Compensation
77
Trim the Analog Output
77
Analog Output Trim or Scaled Analog Output Trim
77
Analog Output Trim
78
Performing a Scaled Output Trim
79
Transmitter-Sensor Matching
79
Switching HART Revision
81
Generic Menu
81
Field Communicator
81
AMS Device Manager
81
Loi
82
Overview
83
Safety Messages
83
4-20 Ma/Hart Output
84
Diagnostic Messages
85
Failed Status
85
Warning Status
86
Other LCD Display Messages
88
Return of Materials
88
SIS Certification
89
Safety Certified Identification
89
Installation
90
Damping
90
Alarm and Saturation Levels
90
SIS Certification
90
Operation and Maintenance
91
Proof Test
91
Partial Proof Test 1
91
Comprehensive Proof Test 2
92
Comprehensive Proof Test 3
92
Inspection
93
Specifications
93
Failure Rate Data
93
Failure Values
93
Product Life
93
A.1 Product Certifications
95
Ordering Information, Specifications, and Drawings
95
Field Communicator Menu Trees
97
Field Communicator Fast Keys
103
C.1 Number Entry
105
Number Entry
105
Text Entry
106
Scrolling
106
C.2 Text Entry
106
C.3 Timeout
108
Timeout
108
Saving and Canceling
108
LOI Menu Tree
109
LOI Menu Tree - Extended Menu
110
Advertisement
Advertisement
Related Products
Emerson Rosemount 644h
Emerson Rosemount 644R
Emerson Rosemount 644 HART
Emerson Rosemount 644T
Emerson Rosemount 648
Emerson Rosemount 6888A
Emerson 6081-P
Emerson Rosemount 644
Emerson 648B
Emerson Fisher 646
Emerson Categories
Controller
Control Unit
Transmitter
Measuring Instruments
Fan
More Emerson Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL