Sign In
Upload
Manuals
Brands
Edwards Manuals
Water Pump
E2M30
Edwards E2M30 Vacuum Pump Manuals
Manuals and User Guides for Edwards E2M30 Vacuum Pump. We have
3
Edwards E2M30 Vacuum Pump manuals available for free PDF download: Instruction Manual
Edwards E2M30 Instruction Manual (56 pages)
Rotary Vacuum Pumps
Brand:
Edwards
| Category:
Water Pump
| Size: 1.76 MB
Table of Contents
Table of Contents
7
1 Safety and Compliance
11
Definition of Warnings and Cautions
11
Safety Symbols
11
2 Introduction
13
Scope and Definitions
13
ATEX Directive Implications
13
Description
13
Gas-Ballast
15
Figure 1 General View of the Pump
15
3 Technical Data
16
Operating and Storage Conditions
16
Performance
16
60 Hz
16
Mechanical Data
17
Figure 2 Single-Phase Motors: Dimensions MM (Inches)
18
Figure 3 Three-Phase Motors: Dimensions MM (Inches)
18
Lubrication Data
19
Electrical Data
19
4 Installation
21
Safety
21
System Design
21
Unpack and Inspect
22
Locate the Pump
22
Fill the Pump with Oil
23
Electrical Installation: Single-Phase Motors
23
Amphenol Version Single-Phase Motors
24
Standard Single-Phase Motors
25
110/200-240 V 50 Hz or 115-120/200-230 V 60 Hz Single-Phase
25
Motors
25
Figure 4 Single-Phase Motors: 220-240 V 50 Hz and 230-240 V 60 Hz
26
Figure 5 Single-Phase Motors: 100 V 50 Hz, 100-105 V 60 Hz and 115 V 60 Hz
26
Figure 6 Single-Phase Motors: 200 V 50 Hz, 200-210 V 60 Hz and 230 V 60 Hz
27
Figure 7: Single-Phase Motors with Amphenol Connector: 220-240 V 50 Hz and 230-240
27
Electrical Installation: Three-Phase Motors
28
Connect the Electrical Supply to the Motor
28
Figure 8: Motor Voltage Selection: Single-Phase Motors, 110/200-240 V 50 Hz and 115-120/200-240 V 60 Hz
28
Check the Direction of Rotation
29
Connect the Pump Inlet
30
Connect the Pump Outlet
30
Gas-Ballast Inlet Connection
31
Leak-Test the System
31
5 Operation
32
ATEX Directive Implications
32
Flammable/Pyrophoric Materials
32
Gas Purges
33
Gas-Ballast Control
33
Start-Up
34
To Achieve Ultimate Vacuum
34
To Pump Condensable Vapours
35
To Decontaminate the Oil
35
Unattended Operation
35
Shut-Down
36
6 Maintenance
37
Safety Information
37
Maintenance Plan
38
Check the Oil Level
38
Replace the Oil
39
Inspect and Clean the Inlet-Filter
39
Clean the Gas-Ballast Filter
40
Figure 9 Remove/Replace the Inlet Filter
40
Clean the Motor Fan-Cover and Enclosure
41
Clean and Overhaul the Pump
41
Replace the Run Capacitor and Test the Motor
41
Figure 10 Remove/Replace the Gas-Ballast Filter
41
Fit New Blades
42
7 Fault Finding
43
The Pump Has Failed to Start
43
The Pump Fails to Achieve Specified Performance
43
Vacuum)
43
The Pump Is Noisy
43
The Pump Surface Temperature Is above 100 °C
44
The Vacuum Is Not Maintained after the Pump Is Switched off
44
The Pumping Speed Is Poor
44
There Is an External Oil Leak
44
8 Storage
45
9 Disposal
46
10 Spares and Accessories
47
Spares
47
Capacitor Selection Table
47
Accessories
48
Figure 11 Accessories
49
Foreline Trap
50
Inlet Catchpot
50
Inlet Chemical Trap
50
Inlet Desiccant Trap
50
Inlet Dust Filter
50
Outlet Mist Filter
50
Solenoid Operated Pipeline Valve
50
Flexible Bellows
51
Gas Ballast Banjo/Elbow Assembly
51
Gas Ballast Valve
51
Oil Drain Extension
51
Pump Inlet Adaptor
51
Pump Outlet Adaptor
51
Vibration Isolators
51
11 PFPE-Prepared EM Pumps
52
Installation
52
Operation
52
Maintenance
52
12 Service
54
Return the Equipment or Components for Service
54
Advertisement
Edwards E2M30 Instruction Manual (48 pages)
Rotary Vacuum Pumps
Brand:
Edwards
| Category:
Water Pump
| Size: 1.42 MB
Table of Contents
Table of Contents
3
Introduction
7
Scope and Definitions
7
ATEX Directive Implications
8
The E2M28/E2M30 Pump
9
Description
10
Gas-Ballast
10
Technical Data
11
Operating and Storage Conditions
11
Performance
11
Mechanical Data
12
Lubrication Data
12
Electrical Data
13
Dimensions (MM)
14
Installation
15
Safety
15
System Design
15
Unpack and Inspect
16
Locate the Pump
16
Fill the Pump with Oil
17
Electrical Installation: Single-Phase Motors
17
Introduction
17
Standard Single-Phase Motors
18
Amphenol Version Single-Phase Motors
18
110/200-240 V 50 Hz or 115-120/200-230 V 60 Hz Single-Phase Motors
18
Electrical Supply Connection: Single-Phase Motors: 220-240 V 50 Hz and 230-240 V 60 Hz
19
Electrical Supply Connection: Single-Phase Motors: 100 V 50 Hz, 100-105 V 60 Hz and 115 V 60 Hz
19
Electrical Supply Connection, Single-Phase Motors: 200 V 50 Hz, 200-210 V 60 Hz and 230 V 60 Hz
20
Electrical Supply Connection, Single-Phase Motors with Amphenol Connector
21
220-240 V 50 Hz and 230-240 V 60 Hz
21
Electrical Installation: Three-Phase Motors
22
Connect the Electrical Supply to the Motor
22
Motor Voltage Selection: Single-Phase Motors, 110/200-240 V 50 Hz and 115-120/200-240 V 60 Hz
22
Check the Direction of Rotation
23
Connect the Pump Inlet
23
Connect the Pump Outlet
24
Gas-Ballast Inlet Connection
24
Leak Test the System
25
Operation
27
ATEX Directive Implications
27
Introduction
27
Flammable/Pyrophoric Materials
27
Gas Purges
28
Gas-Ballast Control
28
Start-Up
29
To Achieve Ultimate Vacuum
29
To Pump Condensable Vapours
30
To Decontaminate the Oil
30
Unattended Operation
30
Shut-Down
30
Maintenance
31
Safety Information
31
Maintenance Plan
31
Check the Oil-Level
32
Replace the Oil
32
Inspect and Clean the Inlet-Filter
33
Remove/Replace the Inlet Filter
33
Clean the Gas-Ballast Filter
34
Clean the Motor Fan-Cover and Enclosure
34
Clean and Overhaul the Pump
34
Remove/Replace the Gas-Ballast Filter
34
Replace the Run Capacitor and Test the Motor
35
Fit New Blades
35
Fault Finding
35
Introduction
35
The Pump Has Failed to Start
35
The Pump Failed to Achieve Specified Performance (Failure to Reach Ultimate Vacuum)
36
The Pump Is Noisy
36
The Pump Surface Temperature Is above 100°C
36
The Vacuum Is Not Maintained after the Pump Is Switched off
37
The Pumping Speed Is Poor
37
There Is an External Oil Leak
37
Storage and Disposal
39
Storage
39
Disposal
39
Service, Spares and Accessories
41
Introduction
41
Service
41
Spares
41
Capacitor Selection Table
42
Accessories
43
Introduction
43
Inlet Catchpot
43
Inlet Dust Filter
43
Inlet Desiccant Trap
43
Inlet Chemical Trap
43
Outlet Mist Filter
43
Accessories
44
Solenoid Operated Pipeline Valve
45
Foreline Trap
45
Vibration Isolators
45
Oil Drain Extension
45
Pump Inlet Adaptor
45
Flexible Bellows
45
Pump Outlet Adaptor
45
Gas Ballast Banjo/Elbow Assembly
45
Gas Ballast Valve
45
PFPE-Prepared EM Pumps
47
Introduction
47
Installation
47
Operation
47
Maintenance
47
Edwards E2M30 Instruction Manual (46 pages)
Rotary Vacuum Pumps
Brand:
Edwards
| Category:
Water Pump
| Size: 1.27 MB
Table of Contents
Table of Contents
3
Introduction
7
Scope and Definitions
7
ATEX Directive Implications
8
The E2M28/E2M30 Pump
9
Description
10
Gas-Ballast
10
Technical Data
11
Operating and Storage Conditions
11
Performance
11
Mechanical Data
12
Lubrication Data
12
Electrical Data
13
Installation
15
Safety
15
System Design
15
Unpack and Inspect
16
Locate the Pump
16
Fill the Pump with Oil
17
Electrical Installation: Single-Phase Motors
17
Introduction
17
Standard Single-Phase Motors
18
Amphenol Version Single-Phase Motors
18
110/200-240 V 50 Hz or 115-120/200-230 V 60 Hz Single-Phase Motors
18
Electrical Supply Connection: Single-Phase Motors: 220-240 V 50 Hz and 230-240 V 60 Hz
19
Electrical Supply Connection: Single-Phase Motors: 100 V 50 Hz, 100-105 V 60 Hz and 115 V 60 Hz
19
Electrical Supply Connection, Single-Phase Motors: 200 V 50 Hz, 200-210 V 60 Hz and 230 V 60 Hz
20
Electrical Supply Connection, Single-Phase Motors with Amphenol Connector
21
220-240 V 50 Hz and 230-240 V 60 Hz
21
Electrical Installation: Three-Phase Motors
22
Connect the Electrical Supply to the Motor
22
Motor Voltage Selection: Single-Phase Motors, 110/200-240 V 50 Hz and 115-120/200-240 V 60 Hz
22
Check the Direction of Rotation
23
Connect the Pump Inlet
23
Connect the Pump Outlet
24
Gas-Ballast Inlet Connection
24
Leak Test the System
24
Operation
25
ATEX Directive Implications
25
Introduction
25
Flammable/Pyrophoric Materials
25
Gas Purges
26
Gas-Ballast Control
26
Start-Up
27
To Achieve Ultimate Vacuum
27
To Pump Condensable Vapours
28
To Decontaminate the Oil
28
Unattended Operation
28
Shut-Down
28
Maintenance
29
Safety Information
29
Maintenance Plan
29
Check the Oil-Level
30
Replace the Oil
30
Inspect and Clean the Inlet-Filter
31
Remove/Replace the Inlet Filter
31
Clean the Gas-Ballast Filter
32
Clean the Motor Fan-Cover and Enclosure
32
Clean and Overhaul the Pump
32
Remove/Replace the Gas-Ballast Filter
32
Replace the Run Capacitor and Test the Motor
33
Fit New Blades
33
Fault Finding
33
Introduction
33
The Pump Has Failed to Start
33
The Pump Fail to Achieve Specified Performance (Failure to Reach Ultimate Vacuum)
34
The Pump Is Noisy
34
The Pump Surface Temperature Is above 100°C
34
The Vacuum Is Not Maintained after the Pump Is Switched off
35
The Pumping Speed Is Poor
35
There Is an External Oil Leak
35
Storage and Disposal
37
Storage
37
Disposal
37
Service, Spares and Accessories
39
Introduction
39
Service
39
Spares
39
Capacitor Selection Table
40
Accessories
41
Introduction
41
Inlet Catchpot
41
Inlet Dust Filter
41
Inlet Desiccant Trap
41
Inlet Chemical Trap
41
Outlet Mist Filter
41
Solenoid Operated Pipeline Valve
43
Foreline Trap
43
Vibration Isolators
43
Oil Drain Extension
43
Pump Inlet Adaptor
43
Flexible Bellows
43
Pump Outlet Adaptor
43
Gas Ballast Banjo/Elbow Assembly
43
Gas Ballast Valve
43
PFPE-Prepared EM Pumps
45
Introduction
45
Installation
45
Operation
45
Maintenance
45
Advertisement
Advertisement
Related Products
Edwards E2M30FX
Edwards E2M0.7
Edwards E2M1.5
Edwards E2M40
Edwards E2M40S
Edwards E2M275
Edwards E2M18-FF
Edwards E2M5
Edwards E2M8
Edwards E2M12
Edwards Categories
Water Pump
Control Unit
Industrial Equipment
Measuring Instruments
Medical Equipment
More Edwards Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL