Daikin RXS35G2V1B9 Manuals
Manuals and User Guides for Daikin RXS35G2V1B9. We have
6
Daikin RXS35G2V1B9 manuals available for free PDF download: Service Manual, Service Manual Removal Procedure
Daikin RXS35G2V1B9 Service Manual (316 pages)
G-Series
Brand:
Daikin
| Category:
Heat Pump
| Size: 10.53 MB
Table of Contents
Table of Contents
4
Introduction
8
Safety Cautions
8
Used Icons
12
Part 1 List of Functions
13
Functions
14
Cooling Only
14
Heat Pump
15
Part 2 Specifications
17
Specifications
18
Cooling Only
18
Specifications
19
Heat Pump
21
Part 3 Printed Circuit Board Connector Wiring Diagram
29
Printed Circuit Board Connector Wiring Diagram
30
Indoor Unit
30
Outdoor Unit
33
Part 4 Function and Control
41
Main Functions
42
Frequency Principle
42
Airflow Direction Control
44
Fan Speed Control for Indoor Units
45
Program Dry Operation
46
Automatic Operation
47
Thermostat Control
48
NIGHT SET Mode
49
ECONO Operation
50
2-Area INTELLIGENT EYE Operation
51
INTELLIGENT EYE Operation
53
Inverter POWERFUL Operation
54
Other Functions
55
Function of Thermistor
56
Control Specification
57
Mode Hierarchy
57
Frequency Control
58
Controls at Mode Changing / Start-Up
60
Discharge Pipe Temperature Control
62
Input Current Control
63
Freeze-Up Protection Control
65
Heating Peak-Cut Control
65
Outdoor Fan Control
66
Liquid Compression Protection Function
66
Defrost Control
67
Electronic Expansion Valve Control
68
Malfunctions
71
Forced Operation Mode
72
Standby Electricity Saving
72
Part 5 Operation Manual
73
System Configuration
74
Ftxs20/25/35/42/50G2V1B
75
Remote Control
75
Auto Dry Cool Heat Fan Operation
76
AUTO · DRY · COOL · HEAT · FAN Operation
76
Adjusting the Airflow Direction
78
COMFORT AIRFLOW and INTELLIGENT EYE Operation
80
POWERFUL Operation
83
OUTDOOR UNIT QUIET Operation
84
ECONO Operation
85
TIMER Operation
86
WEEKLY TIMER Operation
88
Atxs20/25/35/42/50G2V1B
93
Remote Control
93
Auto Dry Cool Heat Fan Operation
94
AUTO · DRY · COOL · HEAT · FAN Operation
94
Adjusting the Airflow Direction
96
COMFORT AIRFLOW Operation
98
INTELLIGENT EYE Operation
99
POWERFUL Operation
101
OUTDOOR UNIT QUIET Operation
102
ECONO Operation
103
TIMER Operation
104
Part 6 Service Diagnosis
106
Caution for Diagnosis
107
Troubleshooting with LED
107
Problem Symptoms and Measures
108
Service Check Function
109
ARC452 Series
109
ARC433 Series
112
Troubleshooting
115
Error Codes and Description
115
Indoor Unit PCB Abnormality
116
Freeze-Up Protection Control or Heating Peak-Cut Control
117
Fan Motor (DC Motor) or Related Abnormality
119
Thermistor or Related Abnormality (Indoor Unit)
121
Signal Transmission Error (between Indoor Unit and Outdoor Unit)
122
Unspecified Voltage (between Indoor Unit and Outdoor Unit)
123
Outdoor Unit PCB Abnormality
124
OL Activation (Compressor Overload)
126
Compressor Lock
127
DC Fan Lock
128
Input Overcurrent Detection
129
Four Way Valve Abnormality
130
Discharge Pipe Temperature Control
132
High Pressure Control in Cooling
134
Compressor System Sensor Abnormality
136
Position Sensor Abnormality
138
DC Voltage / Current Sensor Abnormality (20/25/35/42 Class)
141
CT or Related Abnormality (50 Class)
142
Thermistor or Related Abnormality (Outdoor Unit)
144
Electrical Box Temperature Rise
146
Radiation Fin Temperature Rise
148
Output Overcurrent Detection
150
Refrigerant Shortage
152
Low-Voltage Detection or Over-Voltage Detection
155
Signal Transmission Error on Outdoor Unit PCB
157
(50 Class Only)145
157
Signal Transmission Error on Outdoor Unit PCB (50 Class Only)
157
Check
158
How to Check
158
Four Way Valve Performance Check
159
Thermistor Resistance Check
160
Installation Condition Check
161
Discharge Pressure Check
161
Outdoor Fan System Check
162
Power Supply Waveforms Check
162
Capacitor Voltage Check
163
Power Module Check
163
Rotation Pulse Check on the Outdoor Unit Pcb
164
Main Circuit Short Check
165
Indoor Unit
167
Removal of Air Filter
167
Removal of Front Panel
169
Removal of Front Grille
171
Removal of Horizontal Blades / Vertical Blades
174
Removal of Electrical Box
177
Removal of PCB
180
Removal of Indoor Heat Exchanger
185
Removal of Swing Motors
188
Removal of Fan Motor
192
Outdoor Unit - RK(X)S20-35G2V1B, ARXS20-35G2V1B
195
Removal of Outer Panels / Fan Motor
195
Removal of Electrical Box
204
Removal of Thermistors
208
Removal of PCB
210
Removal of Reactor / Partition Plate
213
Removal of Sound Blanket
215
Removal of Four Way Valve
216
Removal of Compressor
219
Outdoor Unit - RK(X)S20-35G2V1B9
221
Removal of Outer Panels / Fan Motor
221
Outdoor Unit - RK(X)S20-35G2V1B9, ARXS20-35G3V1B
221
Removal of Electrical Box
230
Removal of PCB
233
Removal of Reactor / Partition Plate
241
Removal of Sound Blanket
243
Removal of Four Way Valve
245
Removal of Compressor
248
Outdoor Unit - RK(X)S42G2V1B, ARXS42G2V1B
250
Removal of Outer Panels
250
Removal of Electrical Box
252
Removal of PCB
257
Removal of Sound Blanket
262
Removal of Outdoor Fan / Fan Motor
264
Removal of Thermistors
267
Removal of Four Way Valve / Electronic Expansion Valve
268
Removal of Compressor
271
Outdoor Unit - RK(X)S50G2V1B, ARXS50G2V1B
274
Removal of Outer Panels
274
Removal of Outdoor Fan / Fan Motor
278
Removal of Electrical Box
282
Removal of PCB
287
Removal of Sound Blanket / Thermistors
290
Removal of Four Way Valve
292
Removal of Electronic Expansion Valve
293
Removal of Compressor
294
Trial Operation
298
Part 8 Trial Operation and Field Settings
298
Trial Operation
299
Field Settings
300
Field Settings
301
Model Type Setting
301
When 2 Units Are Installed in 1 Room
301
Standby Electricity Saving
302
Facility Setting Jumper and Switch (Cooling at Low Outdoor Temperature)
303
Jumper and Switch Settings
303
Jumper and Switch Settings
304
Application of Silicon Grease to a Power Transistor and a Diode Bridge
305
Part 9 Appendix
306
Piping Diagrams
307
Indoor Unit
307
Outdoor Unit
308
Outdoor Unit
311
Wiring Diagrams
312
Indoor Unit
312
Advertisement
Daikin RXS35G2V1B9 Service Manual (283 pages)
Inverter Pair
Brand:
Daikin
| Category:
Air Conditioner
| Size: 11.85 MB
Table of Contents
Table of Contents
3
Introduction
7
Safety Cautions
7
Used Icons
11
Part 1 List of Functions
12
Functions
13
Cooling Only
13
Heat Pump
16
Part 2 Specifications
19
Specifications
20
Cooling Only
20
Heat Pump
25
Part 3 Printed Circuit Board Connector Wiring Diagram
30
Printed Circuit Board Connector Wiring Diagram
31
Indoor Unit
31
Outdoor Unit
33
Part 4 Function and Control
41
Main Functions
42
Temperature Control
42
Frequency Principle
42
Airflow Direction Control
44
Fan Speed Control for Indoor Units
45
Program Dry Operation
46
Automatic Operation
47
Thermostat Control
48
NIGHT SET Mode
49
ECONO Operation
50
Inverter POWERFUL Operation
51
Other Functions
52
Function of Thermistor
53
Control Specification
54
Mode Hierarchy
54
Frequency Control
55
Controls at Mode Changing / Start-Up
57
Discharge Pipe Temperature Control
59
Input Current Control
60
Freeze-Up Protection Control
61
Heating Peak-Cut Control
61
Outdoor Fan Control
62
Liquid Compression Protection Function
62
Defrost Control
63
Electronic Expansion Valve Control
64
Malfunctions
67
Forced Operation Mode
68
Standby Electricity Saving
68
Part 5 Operation Manual
69
System Configuration
70
Operation Manual
71
Names of Parts
71
AUTO · DRY · COOL · HEAT · FAN Operation
74
Adjusting the Airflow Direction
76
POWERFUL Operation
78
OUTDOOR UNIT QUIET Operation
79
ECONO Operation
80
TIMER Operation
81
WEEKLY TIMER Operation
83
Part 6 Service Diagnosis
88
Caution for Diagnosis
89
Troubleshooting with LED
89
Problem Symptoms and Measures
90
Service Check Function
91
ARC452 Series
91
Troubleshooting
94
Error Codes and Description
94
Indoor Unit PCB Abnormality
95
Freeze-Up Protection Control or Heating Peak-Cut Control
96
Fan Motor (DC Motor) or Related Abnormality
98
Thermistor or Related Abnormality (Indoor Unit)
100
Signal Transmission Error (between Indoor Unit and Outdoor Unit)
101
Unspecified Voltage (between Indoor Unit and Outdoor Unit)
102
Outdoor Unit PCB Abnormality
103
OL Activation (Compressor Overload)
105
Compressor Lock
106
DC Fan Lock
107
Input Overcurrent Detection
108
Four Way Valve Abnormality
109
Discharge Pipe Temperature Control
111
High Pressure Control in Cooling
112
Compressor System Sensor Abnormality
114
Position Sensor Abnormality
116
DC Voltage / Current Sensor Abnormality (25/35 Class)
119
CT or Related Abnormality (50 Class)
120
Thermistor or Related Abnormality (Outdoor Unit)
122
Electrical Box Temperature Rise
124
Radiation Fin Temperature Rise
127
Output Overcurrent Detection
130
Refrigerant Shortage
132
Low-Voltage Detection or Over-Voltage Detection
135
Signal Transmission Error on Outdoor Unit PCB (50 Class Only)
137
Check
138
How to Check
138
Part 7 Removal Procedure
147
Indoor Unit
148
Removal of Air Filter / Front Panel / Front Grille
148
Removal of Horizontal Blade
152
Removal of Electrical Box
153
Removal of PCB
155
Removal of Vertical Blades
159
Removal of Heat Exchanger
162
Removal of Fan Rotor / Fan Motor
163
Outdoor Unit - RK(X)S25/35F2V1B
165
Removal of Outer Panels / Fan Motor
165
Removal of Electrical Box
174
Removal of PCB
178
Removal of Reactor / Partition Plate
180
Removal of Sound Blanket
182
Removal of Four Way Valve
183
Removal of Compressor
186
Outdoor Unit - RK(X)S25/35G2V1B
188
Removal of Outer Panels / Fan Motor
188
Removal of Electrical Box
197
Removal of Thermistors
201
Removal of PCB
203
Removal of Reactor / Partition Plate
206
Removal of Sound Blanket
208
Removal of Four Way Valve
209
Removal of Compressor
212
Outdoor Unit - RK(X)S25/35G2V1B9
214
Removal of Outer Panels / Fan Motor
214
Removal of Electrical Box
223
Removal of PCB
226
Removal of Reactor / Partition Plate
234
Removal of Sound Blanket
236
Removal of Four Way Valve
238
Removal of Compressor
241
Outdoor Unit - RK(X)S50F2V1B, RK(X)S50G2V1B
243
Removal of Outer Panels
243
Removal of Outdoor Fan / Fan Motor
247
Removal of Electrical Box
251
Removal of PCB
256
Removal of Sound Blanket / Thermistors
259
Removal of Four Way Valve
261
Removal of Electronic Expansion Valve
262
Removal of Compressor
263
Part 8 Trial Operation and Field Settings
266
Trial Operation
267
Field Settings
268
Model Type Setting
268
When 2 Units Are Installed in 1 Room
269
Standby Electricity Saving
270
Facility Setting Jumper and Switch (Cooling at Low Outdoor Temperature)
271
Jumper and Switch Settings
272
Application of Silicon Grease to a Power Transistor and a Diode Bridge
273
Part 9 Appendix
274
Piping Diagrams
275
Indoor Unit
275
Outdoor Unit
276
Wiring Diagrams
279
Indoor Unit
279
Outdoor Unit
280
Daikin RXS35G2V1B9 Service Manual (232 pages)
Inverter Pair Floor/Ceiling Suspended Dual Type BA Series
Brand:
Daikin
| Category:
Air Conditioner
| Size: 11.93 MB
Table of Contents
Table of Contents
4
Introduction
7
Safety Cautions
7
Used Icons
11
Part 1 List of Functions
12
Functions
13
Part 2 Specifications
16
Specifications
17
Cooling Only
17
Heat Pump
20
Part 3 Printed Circuit Board Connector Wiring Diagram
23
Printed Circuit Board Connector Wiring Diagram
24
Indoor Unit
24
Outdoor Unit
26
Part 4 Function and Control
32
Main Functions
33
Temperature Control
33
Frequency Principle
33
Airflow Direction Control
35
Fan Speed Control for Indoor Units
36
Program Dry Operation
37
Automatic Operation
38
Thermostat Control
39
NIGHT SET Mode
40
HOME LEAVE Operation
41
Inverter POWERFUL Operation
42
Other Functions
43
Function of Thermistor
44
Control Specification
45
Mode Hierarchy
45
Frequency Control
46
Controls at Mode Changing / Start-Up
48
Compressor Protection Function
49
Discharge Pipe Temperature Control
50
Input Current Control
51
Freeze-Up Protection Control
52
Heating Peak-Cut Control
52
Outdoor Fan Control
53
Liquid Compression Protection Function
53
Defrost Control
54
Electronic Expansion Valve Control
55
Malfunctions
58
Forced Operation Mode
59
Standby Electricity Saving
59
Part 5 Operation Manual
60
System Configuration
61
Operation Manual
62
Remote Control
62
Auto Dry Cool Heat Fan Operation
63
AUTO · DRY · COOL · HEAT · FAN Operation
63
Adjusting the Airflow Direction
65
POWERFUL Operation
67
OUTDOOR UNIT QUIET Operation
68
HOME LEAVE Operation
69
TIMER Operation
71
Part 6 Service Diagnosis
73
Caution for Diagnosis
74
Troubleshooting with LED
74
Problem Symptoms and Measures
75
ARC433 Series
76
Troubleshooting
79
Error Codes and Description
79
Indoor Unit PCB Abnormality
80
Freeze-Up Protection Control or Heating Peak-Cut Control
81
Fan Motor (AC Motor) or Related Abnormality
83
Thermistor or Related Abnormality (Indoor Unit)
84
Signal Transmission Error (between Indoor Unit and Outdoor Unit)
85
Unspecified Voltage (between Indoor Unit and Outdoor Unit)
86
Outdoor Unit PCB Abnormality
87
OL Activation (Compressor Overload)
88
Compressor Lock
89
DC Fan Lock
90
Input Overcurrent Detection
91
Four Way Valve Abnormality
92
Discharge Pipe Temperature Control
94
High Pressure Control in Cooling
95
Compressor System Sensor Abnormality
96
Position Sensor Abnormality
97
DC Voltage / Current Sensor Abnormality
99
Thermistor or Related Abnormality (Outdoor Unit)
100
Electrical Box Temperature Rise
102
Radiation Fin Temperature Rise
105
Output Overcurrent Detection
108
Refrigerant Shortage
110
Low-Voltage Detection or Over-Voltage Detection
112
Check
114
How to Check
114
Four Way Valve Performance Check
115
Thermistor Resistance Check
116
Installation Condition Check
117
Discharge Pressure Check
117
Outdoor Fan System Check
118
Power Supply Waveforms Check
118
Power Module Check
119
Rotation Pulse Check on the Outdoor Unit Pcb
120
Hall IC Check
121
Main Circuit Short Check
121
Part 7 Removal Procedure
123
Indoor Unit
124
Removal of Air Filter / Front Grille
124
Removal of Front Panel
127
Removal of Horizontal Blade
129
Removal of Signal Receiver Unit / Swing Motor
130
Removal of Discharge Grille
131
Removal of Drain Pan
132
Removal of Electrical Box / PCB
133
Removal of Fan Rotor / Fan Motor
136
Removal of Indoor Heat Exchanger
138
Outdoor Unit - RK(X)S25/35E2V1B
140
Removal of Outer Panels / Fan Motor
140
Removal of Electrical Box
148
Removal of PCB
152
Removal of Reactor / Partition Plate
154
Removal of Sound Blanket
156
Removal of Four Way Valve
158
Removal of Compressor
161
Outdoor Unit - RK(X)S25/35G2V1B
163
Removal of Outer Panels / Fan Motor
163
Removal of Electrical Box
172
Removal of Thermistors
176
Removal of PCB
178
Removal of Reactor / Partition Plate
181
Removal of Sound Blanket
183
Removal of Four Way Valve
184
Removal of Compressor
187
Outdoor Unit - RK(X)S25/35G2V1B9
189
Removal of Outer Panels / Fan Motor
189
Removal of Electrical Box
198
Removal of PCB
201
Removal of Reactor / Partition Plate
209
Removal of Sound Blanket
211
Removal of Four Way Valve
213
Removal of Compressor
216
Part 8 Trial Operation and Field Settings
218
Trial Operation
219
Field Settings
220
When 2 Units Are Installed in 1 Room
220
Standby Electricity Saving
221
Facility Setting Jumper (Cooling at Low Outdoor Temperature)
222
Jumper and Switch Settings
223
Application of Silicon Grease to a Power Transistor and a Diode Bridge
224
Part 9 Appendix
226
Piping Diagrams
227
Indoor Unit
227
Outdoor Unit
228
Wiring Diagrams
230
Indoor Unit
230
Outdoor Unit
230
Advertisement
Daikin RXS35G2V1B9 Service Manual (144 pages)
Inverter Pair Floor / Ceiling Suspended Dual Type FLK(X)S-BA Series
Brand:
Daikin
| Category:
Air Conditioner
| Size: 4.72 MB
Table of Contents
Table of Contents
3
Part 1 List of Functions
3
Part 2 Specifications
3
Part 3 Printed Circuit Board Connector Wiring Diagram
3
Safety Cautions
6
Warnings and Cautions Regarding Safety of Workers
6
Warnings and Cautions Regarding Safety of Users
8
Icons Used
10
Part 1 List of Functions
11
Functions
12
Part 2 Specifications
17
Specifications
18
Cooling Only
18
Heat Pump
21
Part 3 Printed Circuit Board Connector Wiring Diagram
28
Indoor Unit
29
Outdoor Unit
31
Rk(X)S25/35E2V1B
31
Rk(X)S25/35G2V1B
33
Rk(X)S25/35G2V1B9, Rxs25/35J2V1B, Rxs25K3V1B, Rxs35K2V1B, Rxs25/35L2V1B
35
Rxs25/35L3V1B
37
Part 4 Functions and Control
38
Main Functions
39
Temperature Control
39
Frequency Principle
39
Airflow Direction Control
41
Fan Speed Control for Indoor Unit
41
Program Dry Operation
42
Automatic Operation
43
Thermostat Control
44
NIGHT SET Mode
45
HOME LEAVE Operation
46
Inverter POWERFUL Operation
47
Clock Setting
48
Other Functions
49
Thermistor Functions
50
Control Specification
51
Mode Hierarchy
51
Frequency Control
52
Controls at Mode Changing / Start-Up
54
Compressor Protection Function
55
Discharge Pipe Temperature Control
56
Input Current Control
57
Freeze-Up Protection Control
58
Heating Peak-Cut Control
58
Outdoor Fan Control
59
Liquid Compression Protection Function
59
Defrost Control
60
Electronic Expansion Valve Control
61
Pressure Equalizing Control
62
Malfunctions
64
Part 5 Remote Controller
65
Remote Controller
66
Mode Button
67
Quiet Button
67
Reset Button
67
Part 6 Service Diagnosis
68
General Problem Symptoms and Check Items
69
Troubleshooting with LED
70
Indoor Unit
70
Outdoor Unit
70
Service Diagnosis
71
Troubleshooting
74
Error Codes and Descriptions
74
Indoor Unit PCB Abnormality
75
Freeze-Up Protection Control / Heating Peak-Cut Control
76
Fan Motor (AC Motor) or Related Abnormality
77
Thermistor or Related Abnormality (Indoor Unit)
79
Refrigerant Shortage
80
Low-Voltage Detection or Over-Voltage Detection
82
Signal Transmission Error (between Indoor Unit and Outdoor Unit)
84
Unspecified Voltage (between Indoor Unit and Outdoor Unit)
86
Outdoor Unit PCB Abnormality
87
OL Activation (Compressor Overload)
89
Compressor Lock
91
DC Fan Lock
92
Input Overcurrent Detection
93
Four Way Valve Abnormality
94
Discharge Pipe Temperature Control
96
High Pressure Control in Cooling
97
Compressor System Sensor Abnormality
98
Position Sensor Abnormality
99
DC Voltage / Current Sensor Abnormality
101
Thermistor or Related Abnormality (Outdoor Unit)
102
Electrical Box Temperature Rise
104
Radiation Fin Temperature Rise
107
Output Overcurrent Detection
110
Check
112
Thermistor Resistance Check
112
Hall IC Check
113
Power Supply Waveforms Check
113
Electronic Expansion Valve Check
114
Four Way Valve Performance Check
115
Inverter Unit Refrigerant System Check
115
Inverter Analyzer Check
116
Rotation Pulse Check on the Outdoor Unit PCB
118
Installation Condition Check
119
Discharge Pressure Check
119
Outdoor Fan System Check
120
Main Circuit Short Check
120
Power Module Check
122
Part 7 Trial Operation and Field Settings
125
Tips for Servicing
126
Pump down Operation
126
Forced Cooling Operation
126
Trial Operation
128
Field Settings
129
When 2 Units Are Installed in 1 Room
129
Facility Setting Jumper (Cooling at Low Outdoor Temperature)
130
Jumper and Switch Settings
131
Silicone Grease on Power Transistor / Diode Bridge
132
Part 8 Appendix
133
Piping Diagrams
134
Indoor Unit
134
Outdoor Unit
135
Wiring Diagrams
138
Indoor Unit
138
Outdoor Unit
139
Daikin RXS35G2V1B9 Service Manual (137 pages)
Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series
Brand:
Daikin
| Category:
Air Conditioner
| Size: 3.16 MB
Table of Contents
Table of Contents
3
Safety Cautions
6
Warnings and Cautions Regarding Safety of Workers
6
Warnings and Cautions Regarding Safety of Users
8
Used Icons
11
Part 1 List of Functions
12
Functions
13
Part 2 Specifications
18
Specifications
19
Cooling Only
19
Heat Pump
22
Part 3 Printed Circuit Board Connector Wiring Diagram
28
Indoor Unit
29
Outdoor Unit
31
Rk(X)S25/35E2V1B
31
Rk(X)S25/35G2V1B
33
Rk(X)S25/35G2V1B9, Rxs25/35J2V1B, Rxs25K3V1B, Rxs35K2V1B, Rxs35L2V1B
35
Part 4 Function and Control
37
Main Functions
38
Temperature Control
38
Frequency Principle
38
Airflow Direction Control
40
Fan Speed Control for Indoor Unit
40
Program Dry Operation
41
Automatic Operation
42
Thermostat Control
43
NIGHT SET Mode
44
HOME LEAVE Operation
45
Inverter POWERFUL Operation
46
Clock Setting
47
Other Functions
48
Function of Thermistor
49
Control Specification
50
Mode Hierarchy
50
Frequency Control
51
Controls at Mode Changing / Start-Up
53
Compressor Protection Function
54
Discharge Pipe Temperature Control
55
Input Current Control
56
Freeze-Up Protection Control
57
Heating Peak-Cut Control
57
Outdoor Fan Control
58
Liquid Compression Protection Function
58
Defrost Control
59
Electronic Expansion Valve Control
60
Pressure Equalizing Control
61
Malfunctions
63
Part 5 Remote Controller
64
Remote Controller
65
Mode Button
66
Quiet Button
66
Reset Button
66
Part 6 Service Diagnosis
67
General Problem Symptoms and Check Items
68
Troubleshooting with LED
69
Indoor Unit
69
Outdoor Unit
69
Service Diagnosis
70
Troubleshooting
73
Error Codes and Description
73
Indoor Unit PCB Abnormality
74
Freeze-Up Protection Control / Heating Peak-Cut Control
75
Fan Motor (AC Motor) or Related Abnormality
76
Thermistor or Related Abnormality (Indoor Unit)
78
Refrigerant Shortage
79
Low-Voltage Detection or Over-Voltage Detection
81
Signal Transmission Error (between Indoor Unit and Outdoor Unit)
83
Unspecified Voltage (between Indoor Unit and Outdoor Unit)
85
Outdoor Unit PCB Abnormality
86
OL Activation (Compressor Overload)
87
Compressor Lock
89
DC Fan Lock
90
Input Overcurrent Detection
91
Four Way Valve Abnormality
92
Discharge Pipe Temperature Control
94
High Pressure Control in Cooling
95
Compressor System Sensor Abnormality
96
Position Sensor Abnormality
97
DC Voltage / Current Sensor Abnormality
99
Thermistor or Related Abnormality (Outdoor Unit)
100
Electrical Box Temperature Rise
102
Radiation Fin Temperature Rise
105
Output Overcurrent Detection
108
Check
110
Thermistor Resistance Check
110
Hall IC Check
111
Power Supply Waveforms Check
111
Electronic Expansion Valve Check
112
Four Way Valve Performance Check
113
Inverter Unit Refrigerant System Check
113
Inverter Analyzer Check
114
Rotation Pulse Check on the Outdoor Unit PCB
115
Installation Condition Check
116
Discharge Pressure Check
117
Outdoor Fan System Check
117
Main Circuit Short Check
118
Power Module Check
120
Part 7 Trial Operation and Field Settings
122
Pump down Operation
123
Forced Cooling Operation
124
Trial Operation
125
Field Settings
126
When 2 Units Are Installed in 1 Room
126
Facility Setting Jumper (Cooling at Low Outdoor Temperature)
127
Jumper and Switch Settings
128
Silicon Grease on Power Transistor / Diode Bridge
129
Part 8 Appendix
130
Piping Diagrams
131
Indoor Unit
131
Outdoor Unit
132
Wiring Diagrams
134
Indoor Unit
134
Outdoor Unit
134
Daikin RXS35G2V1B9 Service Manual Removal Procedure (33 pages)
2.0/2.5/3.0/3.5 kW Class
Brand:
Daikin
| Category:
Air Conditioner
| Size: 2.3 MB
Table of Contents
Table of Contents
3
Removal of Outer Panels / Fan Motor
4
Removal of Electrical Box
13
Removal of Pcbs
16
Removal of Reactor / Partition Plate
23
Removal of Sound Blankets
25
Removal of Four Way Valve
27
Removal of Compressor
30
Advertisement
Related Products
Daikin RXS35G2V1B
Daikin RXS35LBVMA
Daikin RXS25LBVMA
Daikin RXS25RV1A
Daikin RXSQ-TB Series
Daikin RXSQ48TBVJUB
Daikin RXSQ36TBVJUB
Daikin RXSQ60TBVJUA
Daikin RXS25HV2C
Daikin RXS25G2V1B9
Daikin Categories
Air Conditioner
Heat Pump
Remote Control