Sign In
Upload
Manuals
Brands
CIAT Manuals
Chiller
AQUACIAT LD 300R
User Manuals: CIAT AQUACIAT LD 300R Air Cooled Chiller
Manuals and User Guides for CIAT AQUACIAT LD 300R Air Cooled Chiller. We have
1
CIAT AQUACIAT LD 300R Air Cooled Chiller manual available for free PDF download: Instruction Manual
CIAT AQUACIAT LD 300R Instruction Manual (68 pages)
Brand:
CIAT
| Category:
Chiller
| Size: 8.08 MB
Table of Contents
Table of Contents
3
Introduction and Safety Instructions
5
Receipt of Goods
5
Checking the Equipment Received
5
Handling and Positioning
6
Handling
6
Positioning
6
Dimensions, Clearances, Minimum Installation Distances
7
LD/ILD 150R-300R, Units with and Without Hydraulic Module
7
LD/ILD 360R-600R, Units with and Without Hydraulic Module
8
LD/ILD 150R-300R, Units with Water Buffer Tank Module
9
LD/ILD 360R-600R, Units with Water Buffer Tank Module
10
Free Spaces and Installing Several Units
11
Positioning of Potentially Flammable Zones
11
Physical and Electrical Data for the Units
12
Physical Data LD/ILD 150R - 600R
12
Electrical Data LD/ILD 150R - 600R
14
Short Circuit Current Withstand Capability
14
Electrical Data for the Hydraulic Module
15
Electrical Data Notes for the Compressors
17
Distribution of Compressors Per Circuit
17
Comments on Electrical Data Notes
18
Electrical Connection
19
Power Supply
19
Voltage Phase Imbalance (%)
19
Power Connection/Disconnect Switch
19
Recommended Cable Sections
19
Power Cable Access Routing
21
Field-Installed Control Wiring
21
Electrical Power Reserve for the User
21
Application Data
22
Operating Range
22
Minimum Heat Transfer Fluid Flow Rate (Units Without Factory-Fitted Hydraulic Module)
25
Maximum Heat Transfer Fluid Flow Rate (Units Without Factory-Fitted Hydraulic Module)
25
Variable Flow Water-Cooled Heat Exchanger (Units Without Factory-Fitted Hydraulic Module)
25
Minimum System Water Volume and Water Type Heat Exchanger Flow Rate
25
Maximum System Water Volume
26
Pressure Drop Curves for the Water Exchanger and Standard Water Inlet/Outlet Piping
26
Water Connections
27
Operating Precautions and Recommendations
27
Water Connections
28
Units Without Hydraulic Module
30
Units with Hydraulic Module and Fixed-Speed Pump (for Brine Application Only)
31
Units with Hydraulic Module and Variable-Speed Pump - Pressure Differential Control
32
Units with Hydraulic Module and Variable-Speed Pump - Temperature Difference Control
32
Nominal System Water Flow Rate Control
34
Available Static Pressure for the Installation
34
System Start-Up
36
Checks before System Start-Up
36
Commissioning
36
Essential Points to Check
37
Main Components of the Unit and Operating Characteristics
38
Compressors
38
Lubricant
38
Air-Cooled Exchanger
38
Fans
39
Electronic Expansion Valve (EXV)
40
Moisture Indicator
40
Dehumidifier Filter
40
Water Type Heat Exchanger
40
Refrigerant
40
High-Pressure Safety Pressostat
40
Connect'touch Control
40
Options
41
Tables of Options
41
Description
44
Standard Maintenance
58
Maintenance Levels
58
Level 1 Maintenance
58
Level 2 Maintenance
58
Level 3 Maintenance
59
Tightening of the Electrical Connections
60
Tightening Torques for the Main Fastenings
61
Air-Cooled Exchanger
61
Water Type Heat Exchanger
61
Frequency Inverter
61
Refrigerant Volume
62
Refrigerant Properties
62
Final Shutdown
63
Shutting down
63
Recommendations for Disassembly
63
Fluids to be Recovered for Treatment
63
Materials to be Recovered for Recycling
63
Waste Electrical and Electronic Equipment (WEEE)
63
Unit Start-Up Checklist for Installers Prior to Contacting the Manufacturer
64
Advertisement
Advertisement
Related Products
CIAT LD 300
CIAT LD 350
CIAT AQUACIATPOWER LD 3200R
CIAT AQUACIAT LD 360R
CIAT AQUACIAT LD 390R
CIAT LD 400
CIAT LDC 500
CIAT AQUACIATPOWER LD 0650R
CIAT AQUACIAT LD 600R
CIAT LDH 900
CIAT Categories
Air Conditioner
Chiller
Heat Pump
Air Handlers
Control Unit
More CIAT Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL