User Manuals: Binder VD 53 Vacuum Drying Oven
Manuals and User Guides for Binder VD 53 Vacuum Drying Oven. We have
3
Binder VD 53 Vacuum Drying Oven manuals available for free PDF download: Operating Manual, Mounting Instructions
Binder VD 53 Operating Manual (97 pages)
VD (E2.1) Vacuum drying oven Model version: VD023-230V; VD023UL-120V; VD053-230V; VD053UL-120V; VD115-230V; VD115UL-120V
Brand:
Binder
| Category:
Laboratory Equipment
| Size: 5.64 MB
Table of Contents
Table of Contents
2
1 Safety
5
Legal Considerations
5
Structure of the Safety Instructions
5
Signal Word Panel
5
Safety Alert Symbol
6
Pictograms
6
Word Message Panel Structure
7
Localization / Position of Safety Labels on the Chamber
7
Type Plate
8
General Safety Instructions on Installing and Operating the Chamber
9
Intended Use
11
2 Description of the Equipment
12
Chamber Overview
13
VD 23 Control Panel
14
VD 53 / 115 Control Panel
14
Connections at the Rear of the Chamber
15
3 Completeness of Delivery, Transportation, Storage, and Installation
16
Unpacking, and Checking Equipment and Completeness of Delivery
16
Guidelines for Safe Lifting and Transportation
17
Storage
17
Location of Installation and Ambient Conditions
17
4 Installation and Connections
19
Vacuum Expansion Racks
19
Vacuum Connection
19
Inert Gas Connection
19
Electrical Connection
20
5 Start up
21
Settings at the RD3 Program Controller
21
General Indications on the RD3 Program Controller
22
6 Fixed Value Entry Mode
24
7 Week Program Editor
25
Program Table Template for Week Program Editor
27
Programming Example of the Week Program Editor
28
Desired Time Function
28
Proceeding Overview
28
Proceeding in Detail
29
8 Program Editor
34
Selecting between Set-Point Ramp and Set-Point Step
34
Programming with Setting "Ramp" (Default Setting)
34
Programming with Setting "Step
36
General Notes on Programming Temperature Transitions
37
Set-Point Entry for Program Operation
37
Program Table Template
40
Deleting a Program Section
41
9 Program Start Level
42
10 User Level
45
11 Performance in Case of Failures
51
Performance after Power Failure
51
Alarm Messages
51
12 Temperature Safety Device Class 2
51
13 Reference Measurements. Checking the Temperature in the Inner Chamber
53
14 Commissioning the Vacuum
53
Evacuation
54
Breaking the Vacuum (Flooding with Ambient Air)
54
Operation with Inert Gas
55
15 Switching Contacts 24V DC Via Operation Lines
56
16 Options
57
Connection Kit VD (Option)
57
Vacuum Module Empty (Without Pump) (Option)
57
Vacuum Module with Chemical Membrane Pump VP 1.1 or VP 2.1 (Option)
59
Vacuum Module with Speed Controlled Chemical Membrane Pump VP 3.1 and Vacuum Controller (Option)
61
Digital Pressure Display (Option)
63
Additional Measuring Channel for Digital Object Temperature Display with Flexible Pt 100 Temperature Sensor (Option)
63
Measuring Access Port Vacuum 9 Poles (Option)
64
Communication Software APT-COM™ 3 Datacontrolsystem (Option)
65
17 Maintenance, Cleaning, and Service
65
Maintenance Intervals, Service
65
Cleaning and Decontamination
66
Cleaning
66
Decontamination
67
Sending the Chamber Back to BINDER Gmbh
69
18 Disposal
69
Disposal of the Transport Packing
69
Decommissioning
70
Disposal of the Chamber in the Federal Republic of Germany
70
Disposal of the Chamber in the Member States of the EU Except for the Federal Republic of Germany
71
Disposal of the Chamber in Non-Member States of the EU
73
19 Troubleshooting
73
20 Technical Description
75
Factory Calibration and Adjustment
75
Technical Data
75
Equipment and Options (Extract)
77
Accessories and Spare Parts (Extract)
78
Dimensions VD 23
80
Dimensions VD 53
81
Dimensions VD 115
82
21 Certificates and Declarations of Conformity
83
EU Declaration of Conformity
83
Certificate for the GS Mark of Conformity of the "VDE Prüf- und Zertifizierungsinstitut" (Testing and Certification Institute of the Association for Electrical, Electronic and Information Technologies)
85
22 Product Registration
90
23 Contamination Clearance Certificate
91
For Chambers Located Outside USA and Canada
91
For Chambers Located in USA and Canada
94
Advertisement
Binder VD 53 Operating Manual (83 pages)
Vacuum Drying Ovens with microprocessor program controller RD3
Brand:
Binder
| Category:
Oven
| Size: 2.94 MB
Table of Contents
EC - Declaration of Conformity
2
Product Registration
5
Table of Contents
6
Safety
8
Legal Considerations
8
Structure of the Safety Instructions
8
Signal Word Panel
8
Safety Alert Symbol
9
Pictograms
9
Word Message Panel Structure
10
Localization / Position of Safety Labels on the Unit
10
Type Plate
11
General Safety Instructions on Installing and Operating the Vacuum Drying Oven
12
Intended Use
14
Description of the Equipment
14
Overview of the Equipment
15
VD 23 Control Panel
16
VD 53 / 115 Control Panel
16
Connections at the Rear of the Unit
17
Completeness of Delivery, Transportation, Storage, and Installation
18
Unpacking, and Checking Equipment and Completeness of Delivery
18
Guidelines for Safe Lifting and Transportation
19
Storage
19
Location of Installation and Ambient Conditions
19
Installation and Connections
20
Vacuum Expansion Racks
20
Electrical Connection
21
Vacuum Connection
21
Inert Gas Connection
22
Start up
22
Settings at the RD3 Program Controller
22
General Indications
24
Fixed Value Entry Mode
25
Week Program Editor
26
Program Table Template for Week Program Editor
28
Programming Example of the Week Program Editor
29
Desired Time Function
29
Proceeding Overview
29
Proceeding in Detail
30
Program Editor
35
Selecting between Set-Point Ramp and Set-Point Step
35
Programming with Setting "Ramp" (Default Setting)
35
Programming with Setting "Step
37
General Notes on Programming Temperature Transitions
38
Set-Point Entry for Program Operation
38
Program Table Template
41
Deleting a Program Section
42
Program Start Level
43
User Level
46
Performance in Case of Failures
52
Performance after Power Failure
52
Alarm Messages
52
Safety Device Class 2 (Din 12880)
52
Reference Measurements. Checking the Temperature in the Inner Chamber
53
Commissioning the Vacuum
54
Evacuation
54
Breaking the Vacuum (Flooding)
55
Operation with Inert Gas
55
Switching Contacts 24V DC Via Operation Lines
55
Options
57
Connection Kit VD (Option)
57
Vacuum Module Empty (Without Pump) (Option)
57
Vacuum Module with Chemical Membrane Pump VP 1.1 or VP 2.1 (Option)
59
Vacuum Module with Speed Controlled Chemical Membrane Pump VP 3.1 and Vacuum Controller (Option)
61
Digital Pressure Display (Option)
63
Additional Measuring Channel for Digital Object Temperature Display with Flexible Pt 100 Temperature Sensor (Option)
63
Measuring Access Port Vacuum 9 Poles (Option)
64
Communication Software APT-COM™ 3 Datacontrolsystem (Option)
65
Protocol Printer (Available Via BINDER INDIVIDUAL Customized Solutions)
65
Maintenance, Cleaning, and Service
66
Maintenance Intervals, Service
66
Cleaning and Decontamination
66
Sending the Unit Back to BINDER Gmbh
67
Disposal
68
Disposal of the Transport Packing
68
Decommissioning
68
Disposal of the Unit in the Federal Republic of Germany
69
Disposal of the Unit in the Member States of the EC Except for the Federal Republic of Germany
70
Disposal of the Unit in Non-Member States of the EC
71
Troubleshooting
72
Technical Description
73
Factory Calibration and Adjustment
73
VD Technical Data
74
Equipment and Options
75
Spare Parts
77
Dimensions VD 23
78
Dimensions VD 53
79
Dimensions VD 115
80
Contamination Clearance Certificate
81
binder VD 53 Mounting Instructions (32 pages)
Vacuum Module for Vacuum Drying Ovens
Brand:
binder
| Category:
Oven
| Size: 1.46 MB
Table of Contents
Deutsch
2
1 Sicherheitshinweise
2
Table of Contents
2
2 Lieferumfang
3
Aufstellung
4
3 Montage des Vakuumtrockenschranks auf dem Vakuummodul
4
Montage des Verbindungsblechs
5
Schlauchanschluss am Vakuumtrockenschrank VD
6
Schlauchanschluss am Vakuumtrockenschrank VDL
6
4 Verlegen der Saugleitung
6
Befestigung des Schlauchs an der Gehäuserückwand
7
5 Kondensat-Auffangwanne
8
6 Herstellung des Potenzialausgleichs Beim VDL
9
Potenzialausgleich zwischen Kondensat-Auffangwanne und Vakuum-Modul
9
Potenzialausgleich zwischen VDL und Vakuummodul
9
Potenzialausgleich zwischen Vakuumpumpe und Vakuummodul
10
7 Anschluss einer Absaugung am Vakuummodul
11
Potenzialausgleich zwischen Vakuummodul und der Ableitfähigen Oberfläche am Aufstellungsort
11
English
12
1 Safety Instructions
12
2 Scope of Delivery
13
Installation
14
3 Mounting the Vacuum Drying Oven on the Vacuum Module
14
Mounting the Connecting Plate
15
Hose Connection at the Vacuum Drying Oven VD
16
Hose Connection at the Vacuum Drying Oven VDL
16
4 Installing the Suction Line
16
Fixing the Hose at the Housing Rear
17
5 Condensate Collecting Tray
18
6 Achieving Equipotential Bonding with VDL
19
Equipotential Bonding between the Condensate Collecting Tray and Vacuum Module
19
Equipotential Bonding between the VDL and Vacuum Module
19
Equipotential Bonding between the Vacuum Pump and the Vacuum Module
20
7 Connection of a Suction System at the Vacuum Module
21
Equipotential Bonding between the Vacuum Module and the Conductive Surface of the Installation Site
21
Français
22
1 Consignes de Sécurité
22
2 Etendue de Livraison
23
Installation
24
3 Montage de L'étuve de Séchage À Vide Sur Le Module de Vide
24
Montage de la Plaque de Raccord
25
Connexion du Tube À L'étuve de Séchage À Vide VD
26
Connexion du Tube À L'étuve de Séchage À Vide VDL
26
4 Disposition du Conduit D'aspiration
26
Fixation du Tube À la Face Arrière du Boîtier
27
5 Bac de Rétention de Condensat
28
6 Création de la Liaison Équipotentielle Chez la VDL
29
Liaison Équipotentielle entre la VDL Et Le Module de Vide
29
Liaison Équipotentielle entre Le Bac de Rétention de Condensat Et Le Module de Vide
29
Liaison Équipotentielle entre la Pompe À Vide Et Le Module de Vide
30
Liaison Équipotentielle entre Le Module de Vide Et la Surface Conductrice Au Lieu D'installation
31
7 Raccordement D'une Aspiration Au Module de Vide
31
Advertisement
Advertisement
Related Products
Binder VD 23
Binder VD 23-UL
Binder VD 115-UL
Binder VD 53-UL
Binder VD 115
Binder VD 56
Binder VD 56-UL
binder VD Series
Binder VDL 56
Binder VDL 56-UL
Binder Categories
Laboratory Equipment
Climate chamber
Accessories
Oven
Media Converter
More Binder Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL