Sign In
Upload
Manuals
Brands
Aquacal Manuals
Heat Pump
HeatWave SuperQuiet SQ125
Aquacal HeatWave SuperQuiet SQ125 Manuals
Manuals and User Guides for Aquacal HeatWave SuperQuiet SQ125. We have
7
Aquacal HeatWave SuperQuiet SQ125 manuals available for free PDF download: Installation Manual, Operation Manual, Instruction Manual
Aquacal HeatWave SuperQuiet SQ125 Installation Manual (145 pages)
Brand:
Aquacal
| Category:
Water Pump
| Size: 22.45 MB
Table of Contents
Table of Contents
3
Contacting Aquacal Autopilot, Inc
5
Safety Instructions
5
Installation
7
Positioning Equipment
8
Clearances
9
Dimensions
10
Plumbing
11
Plumbing Requirements
11
Plumbing Diagrams
11
Water Connections to Heat Pump
14
In-Line Chlorine Feeders
15
Water Flow Rates
15
Adjusting Water Flow Using ΔT (Delta-T)
17
Maintaining Ability to Winterize
19
Adjusting Water Pressure Switch
19
Electrical Requirements
20
Electrical
20
Incoming Power Access Holes
23
Access Panels
24
Verifying Transformer Setting
25
Three-Phase Adjustment
26
Schematic Location
26
External Equipment
27
Connecting a Call Flex
27
Connecting a Chlorinator
29
Connecting External Controllers to Heat Pump
30
Connecting Smart Bus Controllers
31
Connecting Two-Wire Controllers (with Internal Thermostat)
35
Connecting Gas Backup Heater to Heat Pump
37
Connecting Multiple Heat Pumps (Master / Slaved)
43
Connecting a Pool/Spa Switching Relay
48
Setting Date and Time
51
Program Heat Pump for the Customer
51
Setting Time and Date Format
52
Selecting Celsius or Fahrenheit
56
Configure Variable Speed Compressors
57
Setting Entry Code Option
62
Using Entry Code to Access Heat Pump
64
Resetting Factory Defaults
64
Cleaning Equipment after Installation
66
- Troubleshooting
68
Fault Codes
68
Issues and Resolutions
68
Troubleshooting
68
AIR TEMP SENSOR OPEN or AIR TEMP SENSOR SHORT
69
Clock Low Battery
69
DEFROST1 SENSOR OPEN or DEFROST2 SENSOR OPEN
70
DEFROST1 SENSOR SHORT or DEFROST2 SENSOR SHORT
70
Error at Master Unit
70
High Pressure Fault
71
High Water Temperature
72
Hp5 System Lockout
72
Low Pressure Fault
73
Lp5 System Lockout
73
Multi-Unit Comm Fault
74
Ota System Lockout
74
Smart Comm Fault
74
Variable Drive Fault
74
WATER TEMP SENSOR SHORT or WATER TEMP SENSOR OPEN
74
Blank Display
75
Display Panel Not Responding
75
Displays "DEFROSTING
76
Displays "NO POOL/SPA WATER FLOW
76
Displays "NO SYSTEM FIRMWARE
76
Displays "SET to SWITCH REMOTELY
77
Displays "SET UNIT MODEL NUMBER
77
Heat Pump Not Running
77
Heat Pump's Tripping Breaker
77
Heat Pump Is Running, Not Heating
78
Heat Pump Won't Shut off
78
Heat Pump Is Running, Not Cooling
79
Ice Forming on the Heat Pump
80
Pool / Spa" Button will Not Work
80
Water Coming from Heat Pump
81
Appendix
82
Factory Defaults
82
Identifying Model Specifications
83
Table of Contents
92
Section 1. Heater Identification Information
93
Important Notices
94
Warranty Information
94
Code Requirements
95
Consumer Information and Safety Information
95
General Specifications
98
Heater Description
99
Putting the Heater into Service
99
Section 3. Installation
99
Specifications
100
Plumbing Connections
101
Below Pool Level Installation
102
Manual By-Pass
102
Valves
102
Gas Connections
103
Sediment Traps
103
Gas Pipe Sizing
104
Outdoor Installation (US and Canada) / Heater Clearances
105
Testing Gas Pressure/Gas Pressure Requirements
105
Outdoor Installation Venting Guidelines
106
Heater Clearances - General Requirements (Indoor Installation for US or Outdoor Shelter for Canada)
107
Indoor Venting - General Requirements (Category I and Category III Requirements)
107
Outside Vent Cover Removal
107
Combustion Air Supply /Direct Air Intake Duct with 3-Inch PVC Pipe (Indoor Installation)
108
Corrosive Vapors and Possible Causes
109
Vent Installation (Indoor Installation for U.S. or Outdoor Shelter for Canada)
110
Horizontal or Vertical Venting - Positive Pressure
113
Garage or Utility Room Installation
116
Outdoor Shelter Vent Installation
116
Control Panel Indexing
117
Final Installation Check
117
Electrical Connections
118
Fireman's Switch Connection/Remote Control Connections
119
Mastertemp Heater Wiring Diagram
120
Electrical Schematic Ladder Diagram
121
Basic System Operation
122
Section 4. Operation
122
Operating
123
To Turn off Gas to Appliance
123
Safety Controls
124
Section 5. Troubleshooting
127
Heater will Not Fire Troubleshooting
128
Burner / Heat Exchanger Troubleshooting
134
Care and Maintenance
135
Pressure Relief Valve
135
Section 6. Maintenance
135
After Start-Up
136
Energy Saving Tips
137
Maintaining Pool Temperature
137
Chemical Balance
138
Replacement Parts
139
Advertisement
Aquacal HeatWave SuperQuiet SQ125 Installation Manual (105 pages)
Brand:
Aquacal
| Category:
Air Conditioner
| Size: 18.91 MB
Table of Contents
Table of Contents
3
Contacting Aquacal Autopilot, Inc
5
Safety
5
Installation
7
Positioning Equipment
8
Plumbing
8
Plumbing Requirements
9
Maintaining Ability to Winterize
9
Water Connections to Heat Pump
9
In-Line Chlorine Feeders
10
Water Flow Rates
10
Electrical
12
Electrical Requirements
12
Incoming Power Access Holes
14
Access Panels
15
Verifying Transformer Setting (Select Units)
16
Schematic Location
16
Connecting Circulation Pumps (Optional)
17
Connections
17
Manually Configure a Circulation Pump
18
Deleting Equipment
20
Connecting an External Controller (Optional)
21
Poolsync
21
FS2 (Pool-Spa)
22
SMART Controllers
24
D 2-Wire Controllers (Pool-Spa)
27
E 3-Wire Controllers (Pool-Off-Spa)
29
Connecting Heat Pumps
30
Connecting Multiple Heat Pumps (Optional)
30
Configure Primary Heat Pump
31
Configure Secondary Heat Pumps
32
Programming
33
Setting Date and Time
34
Setting Date and Time Format
34
Selecting Celsius or Fahrenheit
35
Set a Desired Temperature (Setpoint) for the Heat Pump to Activate
36
Setting Entry Code Option
37
Disabling Entry Code Option
38
Site Configuration Presets (Optional)
39
Configuring Groups
44
Create a Group
45
Edit a Group
46
Delete a Group
47
Configuring Schedules
48
Create a Schedule
48
Edit a Schedule
50
Delete a Schedule
51
Schedule and Program Modes
52
Using Shortcuts
57
Appendix
60
Adjusting Water Flow Using ΔT (Delta-T)
60
Adjusting Water Pressure Switch (Select Units)
62
Available Accessories
63
Configure Variable Speed Compressors (Select Units)
65
Clearances
68
Dimensions
70
Equipment Parameters
71
Factory Reset
72
Freeze Protection
73
FS2 Turbo Boost Enable (Select Units)
75
Identifying Model Specifications
76
Menu Trees
78
Three-Phase Adjustment
80
Viewing System Information
80
Weights
82
Plumbing Diagrams
83
RPM Adjustments
86
Saving Installer Settings to USB
88
Initial Heating Recommendations
89
Initial Cooling Recommendations
89
Service Mode
90
Winterizing
91
Troubleshooting
93
Fault Codes
94
Clock Low Battery
95
DEFROST1 SENSOR OPEN or DEFROST2 SENSOR OPEN
95
DEFROST1 SENSOR SHORT or DEFROST2 SENSOR SHORT
95
Error at Primary Unit
95
HAYWARD Vs Pump FAULT
95
JANDY Vs Pump FAULT
95
High Pressure Fault
96
High Water Temp
96
Hp5 System Lockout
96
Pentair Vs Pump FAULT
96
Hpc Temp System Lockout
97
Low Pressure Fault
97
Lp5 System Lockout
97
Multi-Unit Comm Fault
97
Pool/Spa Group Exists
98
Smart Comm Fault
98
Variable Drive Fault
98
WATER TEMP1 SENSOR SHORT or WATER TEMP1 SENSOR OPEN
98
Water TEMP2 SENSOR SHORT or WATER TEMP2 SENSOR OPEN
98
Blank Display
99
Circulation Pump Won't Activate
99
Display Panel Not Responding
99
Displays "DEFROSTING
99
Issues and Resolutions
99
Displays "FREEZE PROTECTION ACTIVE
100
Displays "NO POOL/SPA WATER FLOW
100
Displays "NO SYSTEM FIRMWARE
100
Displays "SET to SWITCH REMOTELY
100
Displays "UNIT MODEL NUMBER
101
Heat Pump Not Running
101
Heat Pump's Tripping Breaker
101
Heat Pump Is Running, Not Heating
102
Heat Pump Won't Shut off
102
Heat Pump Is Running, Not Cooling
103
Ice Forming on the Heat Pump
103
Pool / Spa" Button Isn't Working
104
Schedule Not Working
104
Water Coming from Heat Pump
104
Aquacal HeatWave SuperQuiet SQ125 Installation Manual (86 pages)
Five (Push) Button Display (HP11 control board)
Brand:
Aquacal
| Category:
Heat Pump
| Size: 9.75 MB
Table of Contents
Table of Contents
3
Contacting Aquacal Autopilot, Inc
5
Safety
5
Installation
7
Positioning Equipment
8
Electrical
9
A Electrical Requirements
9
B Incoming Power Access Holes
11
C Access Panels
11
D Verifying Transformer Setting (Select Units)
12
E Schematic Location
12
Plumbing
13
A Plumbing Requirements
13
B Plumbing Diagrams
13
C Maintaining Ability to Winterize
16
D Water Connections to Heat Pump
16
E In-Line Chlorine Feeders
17
F Water Flow Rates
17
G Heat Pump Bypass Requirements
19
Programming
19
A Setting Date and Time
19
B Setting Date and Time Format
20
C Selecting Celsius or Fahrenheit
21
D Activate HEAT Mode, COOL Mode, AUTO Mode, or Deactivate Equipment
22
E Set a Desired Temperature (Setpoint) for the Heat Pump to Activate
23
F Using Shortcuts
24
Optional Installations
26
A Supplemental Options
26
Optional Programming
27
A Freeze Protection
27
B Setting Entry Code Option
29
C Disabling Entry Code Option
30
D Schedule and Program Modes
32
Appendix
37
Service Mode
37
Service Help
38
Adjustments
38
A Adjusting Water Flow Using ΔT (Delta-T)
39
B Adjusting Water Pressure Switch (Select Units)
41
C Configure Variable Speed Compressors (Select Units)
42
D Three-Phase Adjustment
45
Defaults
46
A Equipment Parameters 2.4.B Factory Reset 2.4.C Menu Trees
46
Supplemental
50
A Additional Options
50
B Available Accessories
50
C Cleaning Equipment after Installation
52
D Clearances
53
E Irrigation and Storm Run-Off
54
F Initial Cooling Recommendations
54
G Initial Heating Recommendations
55
H Saving Installer Settings to USB
55
I Use Installer Settings from USB
56
J Site Configuration Presets (Optional)
58
K Standards
60
L Schematics
60
M Winterizing
61
System Information
63
A Dimensions
63
B Identifying Model Specifications
64
C Viewing System Information
64
D Weights
66
Troubleshooting
68
Fault Codes
70
Aquastar Vs Pump Fault
70
DEFROST1 SENSOR OPEN or DEFROST2 SENSOR OPEN
70
DEFROST1 SENSOR SHORT or DEFROST2 SENSOR SHORT
70
Error at Primary Unit
70
Hayward Vs Pump Fault
71
High Pressure Fault
71
High Water Temp
72
Hp5 System Lockout
72
Hpc Temp System Lockout
72
Jandy Vs Pump Fault
72
Low Pressure Fault
73
Lp5 System Lockout
73
Multiple Primary Fault
74
Multi-Unit Comm Fault
74
Controller Comm
74
Pentair Vs Pump Fault
74
Smart Comm Fault
75
Sta-Rite Vs Pump Fault
75
Variable Drive Fault
75
Vgreen Vs Pump Fault
75
WATER TEMP1 SENSOR SHORT or WATER TEMP1 SENSOR OPEN
76
WATER TEMP2 SENSOR SHORT or WATER TEMP2 SENSOR OPEN
76
Issues and Resolutions
77
Blank Display
77
Circulation Pump Won't Activate
77
Display Panel Not Responding
77
Displays "DEFROSTING
78
Displays "FREEZE PROTECTION ACTIVE
78
Displays "NO SYSTEM FIRMWARE
79
Displays "NO POOL/SPA WATER FLOW
79
Displays "NO POOL/SPA GROUP EXISTS
79
Displays "SET to SWITCH REMOTELY
79
Displays "UNIT MODEL NUMBER
80
Heat Pump Not Running
80
Heat Pump's Tripping Breaker
80
Heat Pump Won't Shut off
81
Heat Pump Is Running, Not Heating
81
Heat Pump Is Running, Not Cooling
82
Ice Forming on the Heat Pump
83
Pool / Spa" Button Isn't Working
84
Schedule Not Working
84
Water Coming from Heat Pump
85
Advertisement
Aquacal HeatWave SuperQuiet SQ125 Operation Manual (58 pages)
Brand:
Aquacal
| Category:
Chiller
| Size: 11.17 MB
Table of Contents
Table of Contents
3
Contacting Aquacal Autopilot, Inc
4
Safety Instructions
4
1 Operation
6
Display Door
6
Wake up Heat Pump
6
Display Panel
7
Activate Heat Mode, Cool Mode, Auto Mode, or Deactivate Equipment
9
Set Temperature
10
Set up Programming
10
Setting Date and Time
10
Using Entry Code to Access Heat Pump
12
Setting Entry Code Option
12
Disabling Entry Code Option
14
Configure Variable Speed Compressors
15
External Equipment
20
Operating Heat Pump with a Call Flex
20
Operating Heat Pump (with an External Controller)
23
Operating Heat Pump (with an External Flow Switch)
23
Operating Heat Pump (with a Gas Back-Up)
23
Using Gas Boost
24
Operating Multiple Connected Heat Pumps
25
2 Maintenance
26
Water Chemistry
26
Cleaning Equipment
27
Clearances
28
Irrigation and Storm Run-Off
29
Water Flow Rates
29
Adjusting Water Flow Using ΔT (Delta-T)
30
Planned Maintenance
32
Winterizing
34
- Troubleshooting
37
3 Troubleshooting
37
Fault Codes
38
AIR TEMP SENSOR OPEN or AIR TEMP SENSOR SHORT
38
Clock Low Battery
38
DEFROST1 SENSOR OPEN or DEFROST2 SENSOR OPEN
39
DEFROST1 SENSOR SHORT or DEFROST2 SENSOR SHORT
39
Error at Master Unit
39
High Pressure Fault
40
High Water Temperature
40
Hp5 System Lockout
41
Low Pressure Fault
41
Lp5 System Lockout
42
Multi-Unit Comm Fault
42
Ota System Lockout
42
Smart Comm Fault
42
Variable Drive Fault
42
Issues and Resolutions
43
WATER TEMP SENSOR SHORT or WATER TEMP SENSOR OPEN
43
Blank Display
43
Display Panel Not Responding
43
Displays "DEFROSTING
44
Displays "NO SYSTEM FIRMWARE
44
Displays "NO POOL/SPA WATER FLOW
44
Displays "SET to SWITCH REMOTELY
45
Displays "SET UNIT MODEL NUMBER
45
Heat Pump Not Running
45
Heat Pump's Tripping Breaker
46
Heat Pump Won't Shut off
46
Heat Pump Is Running, Not Heating
47
Heat Pump Is Running, Not Cooling
48
Ice Forming on the Heat Pump
49
Pool / Spa" Button will Not Work
49
Water Coming from Heat Pump
50
4 Appendix
51
Factory Defaults
51
Identifying Model Specifications
52
Weights
54
Heating Recommendations
55
Cooling Recommendations
55
Available Accessories
55
Aquacal HeatWave SuperQuiet SQ125 Installation Manual (44 pages)
up to 70GPM flow rate
Brand:
Aquacal
| Category:
Heat Pump
| Size: 4.14 MB
Table of Contents
Installation Manual
1
Table of Contents
2
Section 1 - Contacting Aquacal Autopilot, Inc
4
Section 2 - Safety
4
Section 3 - Installation
6
Dimensions
6
Positioning Equipment
8
Plumbing
8
Clearances
8
Water Flow Rates
9
Adjusting Water Flow Using ΔT (Delta-T)
10
Plumbing Requirements
12
Plumbing Diagrams
12
Water Connections to Heat Pump
15
In-Line Chlorine Feeders
16
Maintaining Ability to Winterize
16
Adjusting Water Pressure Switch
17
Electrical
17
Electrical Requirements
17
Electrical Knockouts
19
Access Panels
19
Schematics
20
Verifying Transformer Setting
20
Three-Phase Adjustment
20
Connecting Heat Pump to an External Controller
21
Service Level Programming
22
Section 4 - Operation
26
Energizing Heat Pump
26
Display Door
26
Display Lock
26
Display Panel
26
Buttons
27
Indicator Lights
27
Display
27
User Level Factory Defaults
28
Setting Operating Mode
29
Selecting Celsius or Fahrenheit
29
Setting Thermostats
29
User Lock Option (Enable)
30
User Lock Option (Disable)
31
User Lock Option (Entering Pass Code)
31
Operating Heat Pump (with an External Controller)
32
Section 5 - Maintenance
33
Water Chemistry
33
Cleaning Equipment after Installation
33
Planned Maintenance
34
Winterizing
35
Section 6 - Troubleshooting
37
Fault Codes
37
Issues and Resolutions
39
Section 7 - Appendix
42
Identifying Model Specifications
42
Weights
43
Initial Heating Recommendations
43
Initial Cooling Recommendations
43
Available Accessories
43
Aquacal HeatWave SuperQuiet SQ125 Instruction Manual (41 pages)
Brand:
Aquacal
| Category:
Heat Pump
| Size: 8.65 MB
Table of Contents
Table of Contents
3
Contacting Aquacal Autopilot, Inc
4
Safety
4
Installation
6
Positioning Equipment
6
Plumbing
7
Plumbing Requirements
7
Maintaining Ability to Winterize
7
Water Connections to Heat Pump
8
In-Line Chlorine Feeders
9
Water Flow Rates
9
Electrical
10
Electrical Requirements
10
Incoming Power Access Holes
13
Access Panels
14
Verifying Transformer Setting (Select Units)
15
Schematic Location
15
Connecting an External Controller (Optional)
16
Programming for an External Controller (Optional)
17
Appendix
19
Adjusting Water Flow Using ΔT (Delta-T)
19
Adjusting Water Pressure Switch (Select Units)
21
Available Accessories
22
Clearances
24
Dimensions
25
Identifying Model Specifications
25
Three-Phase Adjustment
27
Weights
28
Plumbing Diagrams
29
Initial Heating Recommendations
31
Initial Cooling Recommendations
32
Winterizing
32
Troubleshooting
34
Fault Codes
35
Issues and Resolutions
38
Aquacal HeatWave SuperQuiet SQ125 Operation Manual (25 pages)
Brand:
Aquacal
| Category:
Heat Pump
| Size: 2.19 MB
Table of Contents
Table of Contents
2
Section 1 - Contacting Aquacal Autopilot, Inc
3
Section 2 - Safety
3
Section 3 - Operation
4
Energizing Heat Pump
4
Display Door
4
Display Lock
4
Display Panel
4
Buttons
5
Indicator Lights
5
Display
5
User Level Factory Defaults
6
Setting Operating Mode
7
Selecting Celsius or Fahrenheit
7
Setting Thermostats
7
User Lock Option (Enable)
8
User Lock Option (Disable)
9
User Lock Option (Entering Pass Code)
9
Operating Heat Pump (with an External Controller)
10
Section 4 - Maintenance
10
Monitoring Conditions
10
Water Chemistry
10
Water Flow Rates
11
Adjusting Water Flow Using ΔT (Delta-T)
12
Irrigation and Storm Run-Off
13
Clearances
13
Cleaning Equipment
14
Planned Maintenance
15
Winterizing
16
Section 5 - Troubleshooting
18
Fault Codes
18
Issues and Resolutions
20
Section 6 - Appendix
23
Identifying Model Specifications
23
Initial Heating Recommendations
24
Initial Cooling Recommendations
24
Available Accessories
24
Advertisement
Related Products
Aquacal HeatWave SuperQuiet SQ120R
Aquacal SQ120BRDSBPR
Aquacal HeatWave SuperQuiet SQ121R
Aquacal SQ125AHDSBNP
Aquacal SQ121ARDSBTC
Aquacal SQ120ARDSBNN
Aquacal SQ120BRDSBNP
Aquacal SQ145GHDSBPB
Aquacal SQ145AHDSBNP
Aquacal HeatWave SuperQuiet SQ155
Aquacal Categories
Heat Pump
Chiller
Controller
Water Filtration Systems
Swimming Pool Heater
More Aquacal Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL