Manuals and User Guides for Agilent Technologies 5975 Series. We have
5
Agilent Technologies 5975 Series manuals available for free PDF download: Operation Manual, Operating Manual, Hardware Installation, Site Preparation Manual
Agilent Technologies 5975 Series Operation Manual (192 pages)
Series MSD
Brand:
Agilent Technologies
| Category:
Laboratory Equipment
| Size: 5.89 MB
Table of Contents
Table of Contents
5
Series MSD Operation Manual for Masshunter
9
1 Introduction
11
Introduction
12
5975 MSD Version
12
Abbreviations Used
13
The 5975 Series MSD
15
CI MSD Hardware Description
17
Important Safety Warnings
19
Electrostatic Discharge Is a Threat to MSD Electronics
19
Many Internal Parts of the MSD Carry Dangerous Voltages
19
Many Parts Are Dangerously Hot
20
The Oil Pan under the Standard Foreline Pump Can be a Fire Hazard
20
Hydrogen Safety
21
GC Precautions
21
Dangers Unique to GC/MSD Operation
22
Hydrogen Accumulation in an MSD
22
Precautions
24
Safety and Regulatory Certifications
26
Information
26
Symbols
27
Electromagnetic Compatibility
28
Sound Emission Declaration
28
Cleaning/Recycling the Product
29
Liquid Spillage
29
Moving or Storing the MSD
29
2 Installing Gc Columns
31
Columns
32
Conditioning Columns
32
Conditioning Ferrules
33
Tips and Hints
33
Installing GC Columns
34
To Reconfigure a 6850 GC Column on Its Basket
34
To Prepare a Capillary Column for Installation
39
To Install a Capillary Column in a Split/Splitless Inlet
41
To Condition a Capillary Column
43
To Install a Capillary Column in the GC/MSD Interface
45
Agilent 7890A and 7820A, and 6890 Gcs
45
6850 Gc
47
3 Operating in Electron Impact (Ei) Mode
51
Operating in Electron Impact (EI) Mode
52
Operating the MSD from the Data System
53
Operating the MSD from the LCP
53
Modes of Operation
53
LCP Status Messages
55
Chemstation Loading <Timestamp
55
Executing <Type>Tune
55
Instrument Available <Timestamp
55
Loading Method <Method Name
55
Loading MSD Firmware
55
Loading os
56
Method Loaded <Method Name
56
Method> Complete <Timestamp
56
MS Locked by <Computer Name
56
Press Sideplate
56
Run: <Method> Acquiring <Datafile
56
To View System Status During Startup
56
LCP Menus
57
The EI GC/MSD Interface
60
Before You Turn on the MSD
62
Pumping down
63
Controlling Temperatures
63
Controlling Column Flow
64
Venting the MSD
65
To View MSD Temperature and Vacuum in Manual Tune
66
To Set Monitors for MSD Temperature and Vacuum Status
67
To Set Analyzer Temperatures from the Instrument Control View
69
To Set the GC/MSD Interface Temperature from Masshunter
71
To Monitor High Vacuum Pressure
72
To Calibrate Column Flow Linear Velocity
74
To Tune the MSD in EI Mode
77
To Verify System Performance
79
To Perform High-Mass Testing (5975 Series Msds)
80
To Remove the MSD Covers
83
To Vent the MSD
85
To Open the Analyzer Chamber
88
To Close the Analyzer Chamber
91
To Pump down the MSD in EI Mode
95
To Move or Store the MSD
97
To Set the Interface Temperature from the GC
99
4 Operating in Chemical Ionization (CI) Mode
101
Operating in Chemical Ionization (CI) Mode
102
General Guidelines
102
The CI GC/MSD Interface
103
To Operate the CI MSD
105
To Switch from the EI Source to the CI Source
106
To Pump down the MSD in CI Mode
107
To Set up the Software for CI Operation
108
To Operate the Reagent Gas Flow Control Module
110
To Set up Methane Reagent Gas Flow
114
To Use Other Reagent Gases
117
To Switch from the CI Source to the EI Source
121
CI Autotune
122
To Perform a PCI Autotune (Methane Only)
124
To Perform an NCI Autotune (Methane Reagent Gas)
126
To Verify PCI Performance
128
To Verify NCI Performance
129
To Monitor CI Mode High Vacuum Pressure
130
5 General Maintenance
133
Before Starting
134
Maintaining the Vacuum System
139
To Replace the Primary Fuses
140
To Remove the EI Ion Source
142
To Disassemble the EI Source
144
To Clean the EI Source
146
To Assemble an EI Source
149
To Replace a Filament in an EI Source
152
To Reinstall the EI Ion Source
154
To Replace the Electron Multiplier Horn
156
6 CI Maintenance
159
General Information
160
To Set up Your MSD for CI Operation
161
To Install the CI Ion Source
162
To Install the CI Interface Tip Seal
164
To Remove the CI Source
165
To Disassemble the CI Source
167
To Clean the CI Source
169
To Assemble the CI Source
171
To Replace a Filament in a CI Source
173
A Chemical Ionization Theory
175
Chemical Ionization Overview
176
Positive CI Theory
178
Negative CI Theory
185
Advertisement
Agilent Technologies 5975 Series Operating Manual (164 pages)
MSD For OpenLAB CDS
Brand:
Agilent Technologies
| Category:
Laboratory Equipment
| Size: 12.43 MB
Table of Contents
Hardware User Information
4
5977B Msd
4
5975/5977 Series MSD Prior to the 5977B MSD
4
Table of Contents
5
Introduction
9
5977B Series MSD Version
10
Abbreviations Used
11
The 5977B Series MSD
13
MSD Hardware Description
15
Important Safety Warnings
16
Hydrogen Safety
19
GC Precautions
19
Precautions
21
Safety and Regulatory Certifications
23
Intended Use
26
Cleaning/Recycling the Product
26
Accidental Liquid Spillage
26
Moving or Storing the MSD
26
To Replace the Primary Fuses
27
Installing 7890/7820/6890/6850 GC Columns
29
Columns
30
To Install a Capillary Column in a Split/Splitless Inlet
32
To Condition a Capillary Column
35
To Install a Capillary Column in the GC/MS Interface Using the Self-Tightening Column Nut
36
To Install a Capillary Column in the GC/MS Interface Using a Standard Column Nut
41
Nut
41
To Install the Interface Tip Seal
44
To Calibrate Column Flow Linear Velocity
46
The GC/MSD Interface for a 7890B Series GC
49
Intuvo 9000 GC Column Maintenance
51
Columns
52
Conditioning Columns
53
Tips and Hints
53
Handling the Intuvo 9000GC Column and Bus Components
54
To Replace an Intuvo GC Column
55
To Replace an Intuvo 9000 GC Gasket
59
To Install a Column Guard or Jumper Chip
60
To Replace the 9000 GC/MS Tail
64
To Condition an Intuvo Capillary Column
68
To Install the Interface Tip Seal
70
The GC/MS Interface for a 9000 Series GC
72
Operating in EI Mode
75
Operating the MSD from the DS
76
Operating the MSD from the GC Control Panel
77
Configuring the MSD through the Web User Interface (WUI)
81
To Change the Network Settings of the MSD
81
Operating the 5975/5977 MSD from the Local Control Panel (LCP)
84
Modes of Operation
84
LCP Status Messages
86
To View System Status During Startup
87
Emodule Mini Display Readout
91
Front Panel Instrument Status LED
91
The GC/MSD Interface
92
Before You Turn on the MSD
94
Pumping down
95
Controlling Temperatures
95
Controlling Column Flow
95
Venting the MSD
96
Set MS Analyzer Temperatures
97
Enable the GC/MS Interface and Oven
99
View MSD Temperatures and Vacuum
100
To Run an Autotune
102
To Open the MSD Covers
103
Vent the MSD
104
To Pump down the MS
106
To Move or Store the MSD
109
General Maintenance
111
Before Starting
112
Maintaining the Vacuum System
116
Maintaining the Analyzer
117
To Open the Analyzer Chamber
119
To Remove the EI HES
121
To Connect/Disconnect Wiring to the EI HES
123
To Disassemble the EI HES
124
To Clean the EI HES
127
To Assemble the EI HES
130
To Remove the EI HES Filaments
135
To Install the EI HES Filament
137
To Install the EI HES
138
To Remove the EI XTR, SS, or Inert Source
139
To Connect/Disconnect Wiring from the EI XTR, SS, and Inert Sources
140
To Disassemble the EI SS or EI Inert Source
141
To Disassemble the EI XTR Source
144
To Clean an EI XTR, SS, or Inert Source
147
To Assemble an EI SS or Inert Source
151
To Assemble the EI XTR Source
154
To Replace a Filament in an EI XTR, SS, or Inert Source
157
To Install the EI XTR, SS, or Inert Source
159
To Replace the Electron Multiplier Horn
160
To Close the Analyzer Chamber
162
Agilent Technologies 5975 Series Operation Manual (128 pages)
MSD for OpenLAB CDS
Brand:
Agilent Technologies
| Category:
Laboratory Equipment
| Size: 6.63 MB
Advertisement
Agilent Technologies 5975 Series Hardware Installation (60 pages)
Mass Selective Detectors
Brand:
Agilent Technologies
| Category:
Security Sensors
| Size: 6.08 MB
Table of Contents
Table of Contents
3
1 General Information
8
Introduction
8
Important Safety Warnings
10
Many Internal Parts of the MSD Carry Dangerous Voltages
10
Electrostatic Discharge Is a Threat to MSD Electronics
10
Many Parts Are Dangerously Hot
11
Hydrogen
11
Safety and Regulatory Certifications
13
Information
13
Symbols
14
Electromagnetic Compatibility
15
Sound Emission Declaration for Germany
15
Cleaning
16
Recycling the Product
16
Customer Responsibilities
17
Before You Start
18
Other Documentation
19
2 Installation
21
Overview
22
Unpacking and Inspecting the Materials
23
Installing the GC
24
Connecting the Helium Lines to the GC
26
Configuring the GC
28
Conditioning the Column
29
Preparing the MSD for Installation
30
Preparing the Vacuum System
31
Plumbing the Methane Line to the CI MSD Flow Module
34
Connecting the MSD and the GC
36
Installing the Chemstation PC
38
Verifying EI System Performance
39
Verify the Tune Performance
39
Verify the Sensitivity Performance
39
Switching from EI to CI Operating Mode
40
Verifying CI System Performance
41
Verify PCI Performance
41
Verify NCI Performance
41
Verifying High Mass CI System Performance
42
Familiarizing the Customer
43
3 Checklists
45
Installation Checklist
46
Verifying that Site Preparation Is Complete
46
Unpacking and Inspecting the Shipped Materials
46
GC Installation
47
MSD Installation
48
MSD Chemstation PC Installation
50
Performance Verification
50
Instrument Log Book Updated
52
Customer Familiarization Checklist
53
Topics Not Included in Familiarization
53
Hardware Overview
54
System Operation
54
MSD Chemstation Software Overview
54
MSD Chemstation Software Autotune Descriptions
54
Methods
55
Data Acquisition
55
Data Analysis
55
Sequence
56
MSD Chemstation Maintenance
56
EI Instrument User Maintenance
56
Troubleshooting (Diagnostics)
57
Tune Charts
57
Additional Support Information
57
Agilent Technologies 5975 Series Site Preparation Manual (44 pages)
Mass Selective Detectors
Brand:
Agilent Technologies
| Category:
Computer Accessories
| Size: 1.71 MB
Table of Contents
Table of Contents
3
1 General Information
6
Instrument Identification
6
5975 MSD Versions
6
Important Safety Warnings
7
Many Internal Parts of the MSD Carry Dangerous Voltages
7
Electrostatic Discharge Is a Threat to MSD Electronics
8
Many Parts Are Dangerously Hot
8
Hydrogen Safety
9
Chemical Safety
10
Safety and Regulatory Certifications
11
Information
11
Symbols
12
Electromagnetic Compatibility
13
Sound Emission Declaration
13
Cleaning
14
Recycling the Product
14
2 Site Preparation
15
Overview
16
Customer Responsibility
16
Agilent Responsibility
17
Other Documentation
19
Space and Weight Requirements
20
Communications Requirements
22
Telephone
22
Site LAN Network
22
Electrical Requirements
23
Voltage Ranges of Major Components
23
Power Configurations
24
Power Requirements
25
Power Plugs and Cord
26
Other Electrical Considerations
27
Air Conditioning and Environmental Requirements
28
Temperature, Humidity, and Altitude
28
Airborne Dust
29
Exhaust Venting
29
Fume (Exhaust) Hood
30
Carrier and Reagent Gas Requirements
31
Regulators, Tubing, and Fittings
32
Laboratory Supply Requirements
33
Cleaning Solvents
33
Data System Supplies
33
Spare Parts and Consumables
34
Receiving the System
37
Delivery and Unloading
37
Inspecting for Damage
37
Storage
38
Unpacking
38
Installation and Verification
39
Installation
39
Verification
39
Sensitivity Specifications
40
Advertisement
Related Products
Agilent Technologies 5975 MSD
Agilent Technologies 5975C TAD VL MSD
Agilent Technologies 5975T LTM GC/MSD
Agilent Technologies 5975T LTM GC
Agilent Technologies 5975T LTM MSD
Agilent Technologies 5977B Series
Agilent Technologies 5977 MSD
Agilent Technologies 5977B Inert+ MSD EI Turbo
Agilent Technologies 5977B HES MSD
Agilent Technologies 5977C MSD