Montigo L42DFN Installation & Maintenance Manual

Montigo L42DFN Installation & Maintenance Manual

L-series residential fireplace l42df indoor

Advertisement

Quick Links

Installation & Maintenance Manual
SCP42
Read and understand this manual. Improper installation, adjustment, alteration,
DIMENSIONS ARE IN INCHES
TOLERANCES:
service or maintenance can cause serious injury, property damage or even death.
FRACTIONAL
TWO PLACE DECIMAL
For assistance or additional information consult a qualified installer, service
CHANGED BY
THREE PLACE DECIMAL
ALL BENDS ARE ASSUMED
agency or the gas supplier.
TO BE 90 UNLESS NOTED
-
-
OTHERWISE.
Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of
this or any other gas burning appliance. A fire or explosion my occur causing serious
injury, property damage or even death.
XG0181
DANGER
NAME
DATE
Description
PC
12/09/2014
Drawn by
1/32"
.015"
DWG. NO.
A
Revision / Date
.005"
Revision
MATERIAL
Finish
SCALE
WARNING
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
Glass doors on gas fireplaces are extremely hot while the fireplace is on and
L42DF WITH SCREEN
ASSY
remain hot even after the fireplace has been turned off. Safety screens are
L42DF-W/SCREEN
available and can reduce the risks of severe burns. Please keep children away
from the fireplace at all times.
1:12
WEIGHT:
SHEET 1 OF 1
Installer: Leave this manual with the appliance. Do not remove.
Consumer: Retain this manual for maintenance and future reference. Do not Discard.
Blank
Blank
Flammable materials
Explosion risk
Toxic
Do not try to light any appliance.
Blank
Flammable materials
Explosion risk
Toxic
Do not touch any electrical switch; do not use any phone in your building.
General Warning
Laser Radiation
Biohazard
Flammable materials
Explosion risk
Toxic
Immediately call your gas supplier from a neighbor's phone. Follow the gas
General Warning
Laser Radiation
Biohazard
Irritant
Slippery floor
Watch your step
Blank
supplier's instructions.
General Warning
Laser Radiation
Biohazard
Irritant
Slippery floor
Watch your step
Gas bottles
Watch for
Electricity
falling objects
Flammable materials
Explosion risk
Toxic
If you cannot reach your gas supplier, call the fire department.
Irritant
Slippery floor
Watch your step
Gas bottles
Watch for
Electricity
falling objects
Low temperature
Strong magnetic field
Optical radiation
General Warning
Laser Radiation
Biohazard
Gas bottles
Watch for
Electricity
falling objects
Low temperature
Strong magnetic field
Optical radiation
Irritant
Slippery floor
Watch your step
Low temperature
Strong magnetic field
Optical radiation
Gas bottles
Watch for
Electricity
falling objects
L42DF Indoor
L-Series
Residential
Fireplace
CAUTION
NOTICE
DANGER
IF YOU SMELL GAS
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Oxidising
Hot surface
Danger of entrapment
Danger of death
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Oxidising
Hot surface
Danger of entrapment
Danger of death
Cutting
High temperatures
Glass hazard
Danger of suffocation
Oxidising
Hot surface
Danger of entrapment
Danger of death
Cutting
High temperatures
Glass hazard
Danger of suffocation
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Cutting
High temperatures
Glass hazard
Danger of suffocation
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Oxidising
Hot surface
Danger of entrapment
Danger of death
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Cutting
High temperatures
Glass hazard
Danger of suffocation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
®
C
US
150204

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the L42DFN and is the answer not in the manual?

Questions and answers

Summary of Contents for Montigo L42DFN

  • Page 1 Danger of harming radiation Environment your hands Gas bottles Watch for Electricity Danger for cutter Entrapment hazard Battery hazard Rotating parts falling objects ® XG0181 150204 Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248...
  • Page 2: Table Of Contents

    L42DF* Indoor Gas Fireplace NOTICE You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for future reference and maintenance. Table of Contents Instruction Manual Contents Maintenance Lighting Instructions See pages 25 to 26. Safety Alerts General Introduction...
  • Page 3: Safety Alert Key

    Introduction Congratulations on your purchase of a Montigo Fireplace. With over 30 years of experience, Montigo is committed to providing you with a gas fireplace that is not only a beautiful addition to your space, but that is also designed and manufactured to the highest safety, reliability and engineering standards.
  • Page 4: Section A: Before You Start

    Should it be impossible to meet the venting requirements laid „ ensure this fireplace is installed in compliance with the manufacturers out in Section 3: Venting, please contact a local Montigo dealer instructions and all applicable codes. regarding the use of a Montigo Power Vent.
  • Page 5: Rating Plate Sample

    L42DF* Indoor Gas Fireplace Installation Rating Plate Sample Figure B: Rating Plate for standing pilot (SIT) Figure A: Rating Plate for IPI eletronic ignition Page 5 XG0181 - 150204...
  • Page 6: Section 1: Installation Overview And Product Dimensions

    L42DF* Indoor Gas Fireplace Installation Section 1: Installation Overview and Product Dimensions Please review the Installation Checklist on Page 4 for general information Safety, as well as efficiency of operation, should be considered when on preparing for a successful installation of your fireplace. selecting the fireplace location.
  • Page 7: Section 2: Framing

    L42DF* Indoor Gas Fireplace Installation Section 2: Framing Frame in the enclosure for the unit with framing materials. The framed Combustible Header, opening for the assembled fireplace is 42" wide, x 37" high x 22⅝" with Supplied shield. 2” Min deep, see Figure 2.
  • Page 8: Clearances

    L42DF* Indoor Gas Fireplace Installation Fireplace without standard screen (pre-January 2015 manufacturing). N.G. & L.P. Top Vent Ceiling Non-Combustible materials. Alcove L42DF* 10" 21" 2" 1" 0" See Section 6 over fireplace. Finishing around Min 1” 1” min. the fireplace 12”...
  • Page 9 L42DF* Indoor Gas Fireplace Installation Framing the Heat Shield Step 3. Nail or screw the top shield in place flush with framing, as shown in figure 9b. Included with the L42DF* Gas fireplace, is a framing heat shield Kit. This Kit is fabricated from galvanized steel and arrives with three (3) pieces, as shown below.
  • Page 10: Section 3: Venting

    4. Install the (5" and 8") collars to the rear vent outlet using the be impossible to ensure that the termination is the highest point or to included hardware, as illustrated Figure 10a. meet the venting guidelines laid out below please contact your Montigo dealer to discuss power venting options. Flue Cover Plate...
  • Page 11: Section 3-2: Installing A Roof Mounted Direct Vent Termination (Pvtk-1)

    L42DF* Indoor Gas Fireplace Installation Section 3-2: Installing a Roof Mounted Direct Vent Termination PVTK1 (PVTK-1) Termination 2’ min. This section applies to installations where the direct vent termination will be roof mounted. Support ring Support plate 32’ max. Section 3-2-1: Venting Layout Obstacle Selection of components and details of venting lay out should adhere to the following guidelines:...
  • Page 12 L42DF* Indoor Gas Fireplace Installation PVTK1 Termination MEXT Sections Support plate 32’ max Support ring 12” Max. Figure 11c. Rear vent, Roof mounted venting (1 = 90° bend). Note: Images are shown without screens for clarity purposes. However, your fireplace should not be operated without proper installation of screens.
  • Page 13 L42DF* Indoor Gas Fireplace Installation Section 3-3: Installation of termination from inside structure Installing a Wall Mounted Direct Vent Termination A Termination with a MOSR Frame is installed from the inside of the This section applies to installations where the direct vent termination structure.
  • Page 14: Section 3-3-1: Venting Layout: Wall Mounted Termination

    If your installation does not fall within 36” Notes Wall Mounted Terminations: TOP VENT the venting parameters, contact a local Montigo dealer for Power All measurements for vertical or horizontal runs are measured „ Venting options. from center of the vent pipe.
  • Page 15 L42DF* Indoor Gas Fireplace Installation 120” Max Heat Shield 96”Min. Figure 14c. Top Vented, wall mounted Retracted Multi-elbow installation. See Venting Graph for Top vent, wall mounted terminations, Figure 14. Note: Images are shown without screens for clarity purposes. However, your fireplace should not be operated without proper installation of screens.
  • Page 16 L42DF* Indoor Gas Fireplace Installation 45° or less Corner Installation. 45° Corner Installation. Use an PTO-4 termination and an PFL-1 or PFL-2/PFL-2 (12" or Attach an PEL-45 (45° elbow) directly onto the flue collar. Cut the PXT- 24" compressed length) and a frame, if appropriate. Flex may be 20 to suit, and attach it to the PEL-45.
  • Page 17 50” 48” If your installation does not fall within 26 5/8” the venting parameters, contact a local Montigo dealer for Power 12” N.G. ONLY Venting options. Figure 16. Rear Vent Venting Graph for wall mounted terminations. Page 17 XG0181 - 150204...
  • Page 18: Section 3-3-2: Venting Components

    PEXT - 1 (12" f/m Section) possible hot spots. PEXT - 2 (24" f/m Section) Montigo recommends the use of a flex section for the final pipe PEXT - 3 (36" f/m Section) „ PEXT - 4 (48" f/m Section) connected directly to the fireplace offering greater flexibility of PEXT - 6 (72"...
  • Page 19: Section 3-3-3: Heat Shields

    L42DF* Indoor Gas Fireplace Installation Section 3-3-3: Heat Shields Installing a Wall Mounted RHS101 Heat shield. Installing a Wall Mounted RHS8 Heat shield The RHS101 Heat shield MUST be used where the RHS8 Termination The RHS8 Heat shield CANNOT be used when the Termination is WITHIN (Figure 17 and 17a) CANNOT be used.
  • Page 20: Section 4: Wiring

    L42DF* Indoor Gas Fireplace Installation Section 4: Wiring Models OPTIONAL L42DFN-F BATTERY PACK L42DFL-F 1.5V AA type 1.5V AA type SPARK GREEN 1.5V AA type WHITE 1.5V AA type BLACK BLACK SENSOR To PPO TO ON/OFF BLUE WALL SWITCH BLUE...
  • Page 21 L42DF* Indoor Gas Fireplace Installation Installing the remote On/Off Wall Switch The L42DF* gas valve may be connected to a wall switch. Do NOT connect any external power to the remote switch. The valve will generate its own power on a millivolt circuit or will draw its power from an AC Connection inside the fireplace, depending on the model of the unit.
  • Page 22: Section 5: Installing The Gas Line

    1/8” N.PT. plug to be fitted with a hose barb. appropriate local codes for your area. DO NOT connect the fireplace to pressures ■ Montigo requires a service shut off valve be located in an in excess of 1/2lbs. This will dampage the gas control valve.
  • Page 23: Section 6: Finishing

    L42DF* Indoor Gas Fireplace Installation Section 6: Finishing Finishing Around the Fireplace Mantels & Surrounds Combustible mantels and mouldings may be safely installed over the NOTE: National Canadian Gas Association mantel test requirements top and on the front of the fireplace provided that they do not project are for fire hazard prevention to combustible materials.
  • Page 24: Section 7: Screen Installation And Removal

    L42DF* Indoor Gas Fireplace Installation Section 7: Screen Installation and Removal Left Side Detail Upper Screen Removing / A Studs Upper Screen The Safety S Stud Catch Removing / Attaching Screens: To Remove th Simply grasp e outer corner of with your thum To Remove Screens: finger and pull...
  • Page 25: Section 8: Installing & Removing The Door

    L42DF* Indoor Gas Fireplace Installation Section 8: Installing & Removing the Door Removing the door: The L42DF* door is removed in a few simple steps. Follow these Step 4: instructions below to remove the Horizontal access panel, unlatch the door buckles and, remove the door. Replace in reverse order. Firmly grasp hand-hold end of Door buckle tool and place the machined...
  • Page 26 The L42DF* has the option of installing the cultured rocks which mimic real stone. These may be spaced at random or in a visual pattern of your preference in the burner tray. See the Montigo web site for photographs www.montigo.com and ideas.
  • Page 27: Section 9: Start-Up Sequence

    L42DF* Indoor Gas Fireplace Operation Section 9: Start-up Sequence For Your Safety - READ BEFORE LIGHTING: with American Flame Electronic Ignition WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. WARNING/ CAUTION: Hot while in operation.
  • Page 28: Sit Proflame 2 Electronic Ignition

    L42DF* Indoor Gas Fireplace Operation SIT Proflame 2 Electronic Ignition Lighting Instructions: 1. STOP! Read the safety information above on this label. 6. Turn fireplace "ON" using wall switch or remote control. 2. Remove the lower Horizontal access panel. 7. If the Fireplace does not light, the System will cycle through two trials, (one minute audible clicking, thirty seconds of silence, and 3.
  • Page 29: Maintenance

    L42DF* Indoor Gas Fireplace Maintenance Maintenance Hi-Lo Burner Adjustment: (SIT Nova 820). Lighting Instructions See pages 25 to 26. The L42DF* is equipped with an adjustable burner, allowing you to raise or lower the flames. To adjust the flames, locate the black knob marked General 'Hi-Lo', in the centre of the gas control valve (See Figure 29).
  • Page 30: Troubleshooting

    If your fireplace still does not operate correctly, consult your local Montigo dealer. All service and repairs should be performed by a qualified Technician. All spare parts, optional fans, and optional trim finishes are available from your local Montigo dealer. Page 30...
  • Page 31: Replacement Parts

    Standing Pilot - Replacement Parts List L42DF RGC1006 NG Gas Valve RGC1005 LP Gas Valve RPA020 NG Pilot RPA021 LP Pilot NG Burner Contact Local Montigo Dealer LP Burner RTC182 Thermocouple RPG001 Thermopile PIEZO Piezo Ignitor RPTA03 Pilot Tubing RDTL42...
  • Page 32: Appendix A: Venting Terminations

    L42DF* Indoor Gas Fireplace Appendix Appendix A: Venting Terminations Location Canada* USA** clearance to the termination frame above grade, veranda, porch, deck, or balcony 12 inches 12 inches clearance to top of doors or operable windows 12 inches 12 inches 12 inches 9 inches clearance to sides or bottom of door or operable windows...
  • Page 33: Appendix B: Warranty

    The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
  • Page 34: Appendix C: State Of Massachusetts

    L42DF* Indoor Gas Fireplace Appendix Appendix C: State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft (2) Revise 10.8.3 by adding the following additional requirements:...
  • Page 35 L42DF* Indoor Gas Fireplace Notes Notes Page 35 XG0181 - 150204...
  • Page 36 L42DF Residential Gas Fireplace XG0181 - 150204...

This manual is also suitable for:

L42dfn-fL42dfl-fL42dflL42df

Table of Contents