Leister Unifloor E Operating Instructions Manual

Leister Unifloor E Operating Instructions Manual

Automatic hot air welding machine
Hide thumbs Also See for Unifloor E:

Advertisement

Quick Links

OPERATING INSTRUCTIONS
GB
LEISTER Unifloor E
Automatic hot air welding machine
Please read the operating instructions carefully before use
and keep for future reference.
APPLICATION
LEISTER Unifloor E
Flooring Automatic Welding Machine
• Welding of PVC coverings and melt welding of linoleum floor coverings.
LEISTER Process Technologies, Riedstrasse, CH-6060 Sarnen / Switzerland
Tel. + 41 41 662 74 74
Fax + 41 41 662 74 16
www.leister.com
sales@leister.com
1
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Unifloor E and is the answer not in the manual?

Questions and answers

Summary of Contents for Leister Unifloor E

  • Page 1 APPLICATION LEISTER Unifloor E Flooring Automatic Welding Machine • Welding of PVC coverings and melt welding of linoleum floor coverings. LEISTER Process Technologies, Riedstrasse, CH-6060 Sarnen / Switzerland www.leister.com sales@leister.com Tel. + 41 41 662 74 74 Fax + 41 41 662 74 16...
  • Page 2: Technical Data

    WARNING Danger! Unplug the tool before opening it, as live compo- nents and connections are exposed. Incorrect use of hot air tools can present a fire and explosion hazard, particularly in the proximity of flammable materials and explosive gases. Danger of getting burned! Do not touch the heater tube and nozzle when they are hot.
  • Page 3: Tool Description

    TOOL DESCRIPTION LEISTER Unfloor E Main components Operating components 1. Housing 14. Main switch 2. Mains cable 15. Drive switch 3. Hot air blower 16. Potentiometer for welding speed 4. Welding nozzle 17. Potentiometer for air flow 5. Connection hose 18.
  • Page 4: Operation

    • If the welding rod de-reeler (24) and lifting device (26) are available: – Attach welding rod de-reeler (24) to the Unifloor E tool using cheese head screw M8 × 20 (25). – Attach lifting device (26) to the tool using socket head cap screw M6 × 30 (27).
  • Page 5 OPERATION LEISTER Unifloor E Tool positioning • Swivel hot air blower (3), using swivel lever (19) up to the stop. • Operate lifting device (26) by means of lifting device lever (13) so that welding rod pressure roller (6) and drive roller (7) are at no-load.
  • Page 6: Maintenance

    • Have your Service Centre check the motor brushes after about 1,000 hours of operation. • Repairs should only be carried out by authorised LEISTER Service Centres. They guarantee a correct and reliable repair service within 24 hours using original spare parts in accordance with the circuit diagrams and spare parts lists.
  • Page 7 ® Service Record LEISTER Unifloor E This document should be handed to the authorised LEISTER Service Center for updating when repaired or serviced. This document is to be retained and kept by the owner of the tool. Technical Data Automatic hot air welding machine Type...
  • Page 8 ® LEISTER Process Technologies, Riedstrasse, CH-6060 Sarnen / Switzerland www.leister.com sales@leister.com Tel. + 41 41 662 74 74 Fax + 41 41 662 74 16...

Table of Contents