Summary of Contents for Betafence Robusta

  • Page 1 MOTORISED CANTILEVER SLIDING GATES ® ® Robusta Bekamatic Industry INSTALLATION MANUAL Ed. 60761 April 2006 ENGLISH...
  • Page 2: Table Of Contents

    Table of contents Guidelines for installation ......3 Guidelines for gate lifting ......3 Foundations .
  • Page 3: Guidelines For Installation

    1. Guidelines for installation • A licensed technician or an installer who has had adequate product training by Betafence N.V. should only install the gate. • The integration of the gate in a fence may not create additional dangerous situations. Please read carefully the warning document and consider the integration examples in the end user manual delivered with the gate.
  • Page 4: Foundations

    3. Foundations • Foundations prepared according to the corresponding drawing. - The gate may not be installed following the slope of the construction site. Make sure that the foundation for the lock post is at the same level as the foundation for the guiding post.
  • Page 5: Gates Opening To The Right

    3.1 Gates opening to the right ® Bekamatic Industry 5/21 ed. April 2006 ENGLISH...
  • Page 6: Gates Opening To The Left

    3.2 Gates opening to the left ® Bekamatic Industry 6/21 ed. April 2006 ENGLISH...
  • Page 7: Preparations Before Gate Installation

    4. Preparations before gate installation 4.1 Required fixation material Chemical anchors M16 x 250 mm (minimum 125 mm anchor depth and minimum 100 mm above Finished Ground Level). For the connection of: - Guiding post (4 pieces) - Lock post (4 pieces) - Rear guiding roller set (4 pieces) Chemical anchors M10 x 200 mm.
  • Page 8: Installation Of The Ground Anchors

    4.2 Installation of the ground anchors 1. Put a tension line in the centre of the position where the gate must be installed. From the point of the lock post to the point where the rear support roll has to come. 2.
  • Page 9: Preparing Installation Levels

    4.3 Preparing installation levels 1. Screw the bottom adjustment nuts on their ground anchors and place the washers on the nuts. 2. The guiding post position will serve as a reference point for further installation of the other guiding parts and posts. The bottom adjustment nuts of the guiding post are levelled as reference towards the concrete level +25 mm.
  • Page 10: Installation Of The Lock Post On The Ground Anchors

    7. Now lower the gate until the rear guiding wheels and the guiding post is resting on the washers of the ground anchors. Put on each ground anchor a washer and a nut. Tighten the nuts slightly for temporary fixation. Remove straps from the base plate of the guiding post.
  • Page 11 3. Close the gate nearly completely by hand and align the lock post. Make sure that the guiding rolls on top of the wing are entering the catcher in the middle. Forcing on one of the sides when adjusting is not tolerable. 4.
  • Page 12 7. Gates with a free passage more than 6m00 have a support roll for the wing in open position. Install that roll on the foundation as described as hereunder. A correct adjustment of this roll is indispensable for a good functioning of a motorised cantilever-sliding gate Bekamatic.
  • Page 13: Adjustment Of The Mechanical End Stops

    8. Adjustment of the mechanical end stops ATTENTION! The verification and/or the adjustment of the mechanical end buffering must always be executed. When the end buffering is not adjusted properly it may cause severe irreversible damage to some parts of the gate. The mechanical end buffering is located on the front- and rear support of the guiding wheels in the under beam.
  • Page 14: Adjustment Of The Rear Mechanical End Buffering

    8.2 Adjustment of the rear mechanical end buffering The rear mechanical end buffering is preinstalled on the support of the rear guiding wheels and is adjustable in length up to 45 cm maximum (Exception: for gates up to 4m, adjustable length up to 20 cm maximum). This is the maximum allowable adjustment with respect to the good functioning of the gate and applied forces.
  • Page 15: Adjustment Of The Correct Motor Pressure

    9. Adjustment of the correct motor pressure 1. Put the wing in the position that it is supported by the rear guiding wheels and the wheels at the position of the guiding post. 2. Turn the threaded rod clockwise. 3. Move the wing slightly back and forward. This will prevent pushing a tooth of the dental wheel on top of a tooth of the dental rack instead of gripping in each other.
  • Page 16: Power Supply

    10. Power Supply 1. Power source must be 240 VAC. Connect the power supply cable on to the connectors of the main switch. Cable coming from the main board to the gate, must be secured according legislations for electrical installations applicable at that time.
  • Page 17: End Switches

    11.3 End Switches Check if the inductive end switches are functioning correctly. Move the wing until fully closed position by hand. The wing should be stopped by the mechanical end stop and a “Lc” indication must appear on the display of the controller board.
  • Page 18 The alignment procedure is quit simple. It is mainly sufficient to align each pair of photocells this way that they ‘look’ at each other. To align the photocells, loosen the ‘block’-screw inside the photocell and manually align the lens to ‘look’ at the other photocell.
  • Page 19: Start The Self-Learning Procedure

    Step 4: Repeat step 1 to 3 for the other transmitter on the guiding post. Step 5: If the alignment is well performed both transmitters will only cover their own receiver. Step 6: Repeat step 1 to 5 for the transmitters on the end post. Tip: if the photocells suffer from interference with sunlight and/or other light sources, it is recommended to align the receiver so that is ‘looks down’...
  • Page 20 1. Configuration Mode To prevent unauthorised change of the control parameters, this option is password protected. The password is entered in the following way: Set the selector switch on position 4 Press the [·]-key once, the display will read [P1] Set the selector switch on position 7 Press the [·]-key once, the display will read [P2] Set the selector switch on position 3...
  • Page 21 Filial manufacturer Betafence NV Werler Drahtwerke GmbH Betafence España, S.L Sales Benelux Betafence Sociedad Unipersonal Deerlijkstraat 58A Runtestrasse 5-9 & 24 C/ López Bravo, 94 B-8550 Zwevegem D-59457 Werl Apartado de correos 347 Tel.: +32 56 73 46 46 Tel.: +49 2922 9890...

Table of Contents