Do you have a question about the EHE0200361 RF and is the answer not in the manual?
Questions and answers
Louise
January 19, 2025
My thermostat isn’t connecting to my boiler although the WiFi is working
1 comments:
Mr. Anderson
February 4, 2025
The EHE0200361 RF thermostat does not use WiFi; it uses a radio frequency (RF) system to communicate with the relay box connected to the boiler. If the thermostat is not connecting to the boiler despite the RF system being in place, it could be due to the following reasons:
1. RF Communication Lost: The RF communication might be disrupted due to the wrong location of the room unit or interference. This is indicated by a red LED on the relay box that is constantly on or flashing.
2. Battery Issue: The thermostat may require new batteries. Replace the batteries and recheck the connection.
3. Manual Control Needed: If RF communication is lost, you can manually control the boiler by pressing the push button on the relay box to turn the boiler on or off.
If these steps do not resolve the issue, contact your installer for further assistance.
This answer is automatically generated
Isabel
March 12, 2025
What do you do if it falls of and won’t turn on
1 comments:
Mr. Anderson
March 12, 2025
If the EHE0200361 RF thermostat screen is blank and won't turn on, follow these steps:
1. Check the Batteries: If no symbols or digits are displayed, install or replace the batteries as instructed in the manual. 2. Verify RF Communication: If the thermostat is not communicating with the relay box, check the relay box's green LED. If it is off, RF communication may be lost. 3. Use the Relay Box Push Button: If RF communication is lost, manually control the boiler using the push button on the relay box. 4. Troubleshoot Further: Refer to the troubleshooting section of the manual for additional steps.
These steps should help restore the thermostat's operation.
Room Thermostat Description The EHE0200361 RF programmable room thermostat is designed to control your heating system efficiently, providing comfortable temperatures when you are at home and energy savings when you are away. The following instructions explain how to program and use the thermostat to provide the most home comfort at the least cost.
Setting-up the EHE0200361 Controls Layout This section shows you how to setup and run the thermostat in 3 simple steps: STEP 1: Installing the Batteries Note: Please follow the instructions in this section only if the thermostat screen is blank (no symbols or digits are displayed). If the room temperature is already displayed move on to Step 2: Setting the Date and Time.
Programming the EHE0200361 Programming the EHE0200361 The Built-in Heating Program The temperature setting for period on Monday (Day 1) will now be flashing. To adjust this press the buttons and confirm the setting again by pressing the The built-in heating program has 4 temperature level changes per day that can be set button.
Operating the EHE0200361 Troubleshooting the EHE0200361 Choosing the Operating Mode Symptom Remedy Blank Display (Power Loss). Check batteries are installed by removing the The thermostat can operate in three different modes: Automatic, Manual or Off. To battery cover. set the operating mode press either of the AUTO, MAN or OFF buttons. The screen indicates which mode is currently active by displaying AUTO, MAN or OFF.
Page 5
Relay Box Controls layout The relay box will normally be found mounted close Push button to the boiler. and relay status LED’s What does it mean when the Relay Box green LED is ON? The green LED indicates normal operation of the radio frequency system. When the green LED is ON the boiler is also ON.
Need help?
Do you have a question about the EHE0200361 RF and is the answer not in the manual?
Questions and answers
My thermostat isn’t connecting to my boiler although the WiFi is working
The EHE0200361 RF thermostat does not use WiFi; it uses a radio frequency (RF) system to communicate with the relay box connected to the boiler. If the thermostat is not connecting to the boiler despite the RF system being in place, it could be due to the following reasons:
1. RF Communication Lost: The RF communication might be disrupted due to the wrong location of the room unit or interference. This is indicated by a red LED on the relay box that is constantly on or flashing.
2. Battery Issue: The thermostat may require new batteries. Replace the batteries and recheck the connection.
3. Manual Control Needed: If RF communication is lost, you can manually control the boiler by pressing the push button on the relay box to turn the boiler on or off.
If these steps do not resolve the issue, contact your installer for further assistance.
This answer is automatically generated
What do you do if it falls of and won’t turn on
If the EHE0200361 RF thermostat screen is blank and won't turn on, follow these steps:
1. Check the Batteries: If no symbols or digits are displayed, install or replace the batteries as instructed in the manual.
2. Verify RF Communication: If the thermostat is not communicating with the relay box, check the relay box's green LED. If it is off, RF communication may be lost.
3. Use the Relay Box Push Button: If RF communication is lost, manually control the boiler using the push button on the relay box.
4. Troubleshoot Further: Refer to the troubleshooting section of the manual for additional steps.
These steps should help restore the thermostat's operation.
This answer is automatically generated