Cordex TC7000 User Manual

Cordex TC7000 User Manual

Intrinsically safe thermal imaging camera
Hide thumbs Also See for TC7000:

Advertisement

Quick Links

USER
MANUAL
TC7000/TC7150
INTRINSICALLY
SAFE THERMAL
IMAGING CAMERA
RUGGED
AUTHORITY
www.cord-ex.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TC7000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Cordex TC7000

  • Page 1 USER MANUAL TC7000/TC7150 INTRINSICALLY SAFE THERMAL IMAGING CAMERA RUGGED AUTHORITY www.cord-ex.com...
  • Page 2: Table Of Contents

    Storing And Analysing Images Technical Information Ten Suggestions For Thermography Best Practice Your CorDEX intrinsically safe thermal imaging is ATEX, IECEx and NRTL certified. For specific certification levels and Special Considerations for Safe Use, refer to the latest revisions of Manuals;...
  • Page 3: Getting To Know Your Infrared Camera

    Wrist Strap Points Image Save Menu Key Level + RFID Scanner USB Connection Point Power Switch Span + Level - Focus Ring 135˚ Swivel Lens View Key Span - Joystick Focus Ring 135˚ Swivel Lens RUGGED AUTHORITY Document Reference TC7000/TC7150UM Rev. B...
  • Page 4: Getting Started

    (simply careful attention to the orientation of the pack. understand the implication of looking for temperature difference) or are these parameters. you going to attempt to make an accurate temperature measurement? RUGGED AUTHORITY Document Reference TC7000/TC7150UM Rev. B...
  • Page 5: A Guide To Your Home Screen

    When the crosshair is highlighted, pressing and holding the joystick will allow the emissivity of that spot only to be changed. IW Series IR Window Correction enabled icon RUGGED AUTHORITY Document Reference TC7000/TC7150UM Rev. B...
  • Page 6: Menu Selection

    (spot) selection (0,1,2 or 3), maximum temperature display (within entire image), minimum temperature display (within entire image). (See detailed analysis section on P.12) RUGGED AUTHORITY Document Reference TC7000/TC7150UM Rev. B...
  • Page 7: Rfid

    . Use the joystick to highlight the alias section (complete with selecting OK) and then input a simple description through the qwerty options (complete with selecting OK - this can be edited later in CorDEX CONNECT) • Select whether the RFID Tag is built into a CorDEX IR window (IW2000, IW3000, The analysis menu is split into two sections;...
  • Page 8: Settings

    Celsius, Fahrenheit or Kelvin distance from target object. temperature display Brightness Adjustment. Select the backlight brightness in Levels 1 – 8. Level 1 being the lowest and level 8 being the highest. RUGGED AUTHORITY Document Reference TC7000/TC7150UM Rev. B...
  • Page 9: Level/Span

    Moving the To move the spot to the desired location on the joystick up and down will change the display screen use the joystick. colour palette. RUGGED AUTHORITY Document Reference TC7000/TC7150UM Rev. B...
  • Page 10: Ten Suggestions For Thermography Best Practice

    -40°F to +158°F (-40°C to +70°C) hours where fatigue could cause an important Display 3.2” Backlit LCD anomaly to be overlooked. Software CorDEX CONNECT (Included) Batteries Removable and Rechargeable Battery Life Upto 8 hours RUGGED AUTHORITY Document Reference TC7000/TC7150UM Rev. B...
  • Page 11 Choose a report software package that creates a scheduled job sheet to pass straight to the maintenance engineer. RUGGED AUTHORITY Document Reference TC7000/TC7150UM Rev. B...
  • Page 12 TC7000/TC7150 – User Manual RUGGED AUTHORITY Document Reference TC7000/TC7150UM Rev. B...
  • Page 13 Copyright © 2015, CorDEX Instruments Limited. All other brand and product names are trademarks of CorDEX Instruments Limited. Document Reference TC7000/TC7150UM Rev. B...

This manual is also suitable for:

Tc7150