Page 2
Only use such batteries, headphones, camera recorder, gas sensor, cable and connection The quality of the received signal is related directly to its cleanness. The received components that are approved by Nokta Engineering. Use of any unapproved accessory signal might be affected from many environmental factors like mineral intensive may damage your unit.
Page 3
Use the battery according to the instructions written in the user’s manual prepared by Nokta Engineering. Do not expose the battery to heat. Hot and Cold Do not expose your device and search coils directly to fire. Do not keep them in a very cold environment for a long period of time.
Page 4
Smart Detection Heads Sensitivity On the Golden King Deep Processor Radar, there are 3 types You can use the Golden King Deep Processor Radar of search coils suitable for every purpose. The search coils system at any depth you desire by setting the sensitivity detect every move of the user and minimize the negative levelthrough the sensitivity menu.
Page 5
Gas Sensor come across during your search. Due to the gas sensor available on the Golden King Deep Processor Radar system, you can check whether the confined areas (caves, tunnels, cisterns, shelters) contain...
Contents Unpacking Ground balance Ground balance 20-23 Make sure all the parts are present. Equipment Detection functions Interface selection Keys - features and locations Digital detection 24-25 25-26 Gauge detection Starting Result screen Initial steps to operate the equipment Technical specifications Preparing and charging the equipment Assembly Menu descriptions...
• Gas sensor (optional) Multi-functional keypad angle • Headphones All these parts can be obtained from the Gas sensor dealers of Nokta Engineering. socket input Please do not use any external or any other branded item. Search coils socket input...
Page 8
Equipment System Box Camera recorder input Headphones socket input Gas sensor socket input Battery Search coil socket input Battery Battery compaction apparattus compaction apparattus...
Plug it into a 220V wall socket. Starting Initial steps to operate the equipment Preparing and charging the equipment You are required to charge the battery before initial use. The battery box is removed by opening the clamping apparatus on the system box.
Starting The extension bar to which the armlet and the joystick are connected is removed from the bag. The search coil is attached to the bobbin connection component on the extension bar with the bobbin clamping screws. The connector at the end of the extension bar is inserted in its Assembly place on the search coil and the connector next to the armlet is inserted in its place on the system box.
Starting Keys and Screen Standby Key On / Off Switch It is the key to turn off the entire system. After charging the battery, turn the system off by pressing the OFF button and place the battery box in its place on the system box. Back Key The function of the back key is to return to the previous Then, in order to turn on the system,...
Page 12
Starting Ground Balance Key Left Direction Key This key is used to access the ground balance menu. It is the left direction key to go leftward on the options You can select either the automatic or the manual on the menu screens. option from the ground balance menu when needed.
Page 13
Starting Numeric Keys It is the multi-functional section of the keypad. Especially at the time of recording, it lets you Do not expose your monitor to fire directly. enter the Date / Region / Name and the Time. Press the key until the character you desire appears on the screen.
Starting Accessing Menu Functions Detection There are 2 methods to access the menu functions of the Golden King To search with the Golden King Deep Processor Radar, you should Deep Processor Radar. select one of the two interface options. Method 1: Is the multi-functional keypad on the system box.
If you do not want to save the result screen, press the “BACK” key and return to the ground balance selection screen. When you press the You can save the findings obtained by the Golden King Deep Processor Radar as well as the result screen reports and graphs. In order to save “SAVE”...
Page 16
CAMERA MENU: You can watch the videos you have previously recorded in the Golden King Deep Processor Radar In order to access the «3D RESULT» and the «CAMERA» recordings system. In order to watch a video , please press the «SAVE»...
Golden King Deep Processor Radar system. To view the 3D result screens, please press the The Golden King Deep Processor Radar system is equipped with a special «SAVE» key on the keypad. Using the right/ left...
Page 18
Use of Additional Features After the camera’s socket is inserted into the camera recorder’s input jack, press the camera key on the keypad. Approximately within 15-20 PLEASE ENTER DATE / NAME / REGION seconds, the interface below will come up. Here the camera is in the INFO BY USING LETTERS AND NUMBERS preview mode and it will show the current view.
Page 19
Use of Additional Features PAUSE PAUSE BUTTON PAUSE DATE NAME REGION When viewing the saved videos, you can pause any moment 0 2 /0 4 /2 0 0 8 R E C O R D 1 I S T A N B U L STOP of the video indefinitely by using the “PAUSE”...
Page 20
Use of Additional Features ½ X ¼ X ½ X BUTTON ¼ X BUTTON If slower viewing is needed, press the “¼ X” button to watch the video recorded on 30 fps as 7 fps. The video will now play at 1/4 of the normal speed. When viewing the videos you have recorded, your system is designed to display 30 frames per second (fps).
Use of Additional Features Gas Sensor The Golden King Deep Processor Radar system is equipped with a gas sensor which measures and informs the user of the presence of methane gas which is one of the flammable, explosive and toxic gases in confined places.
Page 22
Use of Additional Features After measuring, the user is warned by one of the two results: First one is: “SAFE METHANE LEVEL” “THERE MAY BE DIFFERENT GASES, WEAR GAS MASK FOR YOUR SAFETY” The gas sensor socket input is shown in the picture below. “SAFE METHANE LEVEL”...
Use of the Search Coil Headphones When designing the Golden King Deep Processor Radar, it was our first and one of the most important goals to consider all the needs of the user on the field and to provide the best results while fulfilling these needs.
Page 24
The surface search coil has also high capability of metal discrimination. No matter how small the target is, you will not miss it. The Smart Search Coils and the entire Golden King Deep Processor Radar system have been developed after comprehensive R&D activities, both electronical and chemical.
With the Golden King Deep Processor Radar system, you can search with or resolution. With the deep search coil that is 100x60cm in size, you will be able without swaying the search coil.
Ground Balance AUTOMATIC GROUND BALANCE Ground Balance On the Golden King Deep Processor Radar system, ground balancing is done through the “GROUND BALANCE” menu. You can access the ground balance menu both from the settings section or by pressing the “GROUND BALANCE”...
Ground Balance Please continue these steps until the box with the soil on the left side completely turns to green. The soil in the box will decrease each time you After pressing the «RESET» button, following the animated guide on the screen, follow these steps depending on the mineral composition of the ground.
Page 28
Ground Balance Raise the search coil 40cm above the ground and press the “- / +” key on the keypad for an estimated number of times to eliminate the effect. Because the effect is in the positive direction in the example below, you should press the “+”...
RESET BUTTON Interface Selection The Golden King Deep Processor Radar system offers two types of detection interfaces. First one is “ DIGITAL” and the second one is “GAUGE” interface. The user can search by selecting the interface which he/she will use most conveniently.
RADAR SCREEN Another new feature of the Golden King Deep Processor Radar is the SMART DETECTION COILS RADAR SCREEN. Due to this screen, while the user is following the operation...
During your search, you will be able to follow all the data and information received from the target signal by the GAUGE DETECTION on this screen The Gauge option on the Golden King Deep Processor Radar system has such as whether the metal is ferrous or non- ferrous, whether it is alloy or been designed as a convenient detection interface, considering the users’...
Page 32
PLEASE HOLD “CONFIRM” BUTTON AND PASS OVER THE TARGET TO GET ALL INFORMATION During your searches with the Golden King Deep Processor Radar, you will ABOUT THE TARGET. easily follow the amplitude of the the target signal in real time on the SCOPE Screen.
210 x 315 360 X 440 600 X 1000 the Golden King Deep Processor Radar in real time. On the result screen, there are 3 graph windows. 1st window is the top view of the signal, 2nd window is Frequency 12.5 kHz...
Page 34
Menu Description LANGUAGE SELECTION MENU: +100 It consists of 10 languages: BRIGHTNESS MENU: Turkish, English, Greek, Persian, In this menu, you can adjust the brightness Bulgarian, Arabic, French, Spanish, of the screen. You can increase or German and Russian. Once the user decrease the brightness as you wish.
Menu Descriptions CAMERA RECORDER MENU: INTERFACE SELECTION MENU: On the system, a camera recording Interface selection consists of 2 GOLD system is used which can take shots alternatives to provide you with a more at a high display quality both on land METAL MINERAL convenient use during your search.
You can practice searching by following this presentation. We, as Nokta Engineering, have focused on the ease of use for this system. Your searches and detections with the GOLDEN KING DEEP PROCESSOR RADAR which incorporates everything you PLEASE PRESS THE «ON»...
Page 37
+100 BRIGHTNESS SETTING PLEASE SET THE VOLUME OF YOUR SYSTEM PLEASE SET THE BRIGHTNESS OF THE BY USING THE RIGHT-LEFT DIRECTION KEYS. SCREEN. TO EXIT THE MENU, PRESS THE TO EXIT THE MENU, PRESS THE “BACK” KEY. “BACK” KEY. FERROUS SETTING PLEASE SET THE SENSITIVITY LEVEL.
Page 38
GROUND BALANCE PLEASE SELECT EITHER THE AUTOMATIC OR PLEASE SELECT THE DETECTION SCREEN THE MANUAL GROUND BALANCE USING USING THE RIGHT/LEFT DIRECTION KEYS. THE RIGHT/LEFT DIRECTION KEYS. TO EXIT TO EXIT THE MENU, PRESS THE “BACK” KEY. THE MENU, PRESS THE “BACK” KEY. AUTOMATIC GROUND BALANCE AUTOMATIC GROUND BALANCE MAKSÝMUM ÜST SEVÝYE...
Page 39
Confirm Button AUTOMATIC GROUND BALANCE AUTOMATIC GROUND BALANCE MAXIMUM LOWER LEVEL MAXIMUM UPPER LEVEL MAKSÝMUM ÜST SEVÝYE Reset Button RESET CONFIRM 40cm 10cm 40cm 10cm NOW LOWER THE DETECTION COIL TO 10cm ABOVE THE GROUND AS SHOWN IN THE PLEASE RAISE YOUR SEARCH COIL TO 40cm ANIMATION.
Page 40
Confirm Button AUTOMATIC GROUND BALANCE MAXIMUM LOWER LEVEL CONFIRM 10cm WHEN THE BOX COMPLETELY TURNS TO GREEN, WHEN A TARGET IS DETECTED PLEASE IT MEANS THAT THE GROUND BALANCE IS COMPLETED SUCCESFULLY. AFTER THE GROUND BALANCE IS DETERMINE THE CENTER OF THE TARGET BY COMPLETED, A MESSAGE INDICATING THE START THE SCOPE SCREEN AND PRESS THE «OK»...
Page 41
Confirm Button Confirm Button YOU DETECTED A TARGET! YOU DETECTED A TARGET! PLEASE HOLD “CONFIRM” BUTTON AND PASS PLEASE HOLD “CONFIRM” BUTTON AND PASS OVER THE TARGET TO GET ALL INFORMATION OVER THE TARGET TO GET ALL INFORMATION ABOUT THE TARGET. ABOUT THE TARGET.
Page 42
IF YOU DESIRE TO SAVE 3D RESULT SCREEN, PRESS SAVE KEY ON THE KEYPAD. DATE NAME REGION _ _ /_ _ /_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ TO EXIT WITHOUT SAVING, PLEASE PRESS BACK KEY.
Page 43
The pH value of the soil and the mineral it contains as well as the rich metal structure are factors leading to fast or slow reaction. For this reason, big metals at depths which normally cannot be detected may be detected by the GOLDEN KING DEEP PROCESSOR RADAR at depths up to 8m provided that the above-mentioned conditions are present.
Need help?
Do you have a question about the Golden King and is the answer not in the manual?
Questions and answers