Table of Contents

Advertisement

Quick Links

®
R6 Series
Stonex
User Manual
Version 1.0
English

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R6 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for STONEX R6 Series

  • Page 1 ® R6 Series Stonex User Manual Version 1.0 English...
  • Page 2: Table Of Contents

    R6, Table of Contents Table of Contents In this manual Chapter Page Description of the System System Components Container Contents Instrument Components User Interface Keyboard Screen Status Icons Softkeys Operating Principles Pointsearch Operation Instrument Setup Working with the Battery Data Storage Main Menu Survey Application Distance Measurements ‐ Guidelines for Correct Results Settings General Settings EDM Settings Communication Settings Tools Calibration Auto Start Routine System Information Loading Software Functions Overview Distance Offset...
  • Page 3 R6, Table of Contents Z‐Coordinate 2 Dist. Offset Control Distance EDM Continuous Coding Applications ­ Getting Started Overview Starting an Application Selecting the Job Selecting the Station Selecting the Orientation 8.5.1 Overview 8.5.2 Manual Orientation 8.5.3 Orientation with Coordinates Applications Common Fields Survey Reference Element ‐ Reference Line 9.3.1 Overview 9.3.2 Defining the Base Line 9.3.3 Defining the Reference Line 9.3.4 Subapplication Measure Line & Offset 9.3.5 Subapplication Setout Reference Element ‐ Reference Arc 9.4.1 Overview 9.4.2 Defining the Reference Arc 9.4.3 Subapplication Measure Line & Offset 9.4.4 Subapplication Setout...
  • Page 4 R6, Table of Contents 9.7.3 Computation Procedure 9.7.4 Resection Results Set Out Area & Volume 9.10 Remote Elevation 9.11 Construction 9.11.1 Starting Construction 9.11.2 Layout 9.11.3 As Built Check Data Management 10.1 Data Management 10.2 Exporting Data 10.3 Importing Data 10.4 Working with a USB Memory Stick 10.5 Working with Bluetooth 10.6 Working with GeoMax Geo Office  and GGO Tools  Calibration 11.1 Overview 11.2 Preparation 11.3 Calibrating Line‐of‐Sight and Vertical Index Error 11.4 Calibrating the Circular Level of the Instrument and Tribrach 11.5 Inspecting the Laser Plummet of the Instrument...
  • Page 5 R6, Table of Contents 13.6.3 Distancer, Measurements without Reflectors (Reflectorless  mode) 13.6.4 Laser Plummet 13.7 Electromagnetic Compatibility EMC 13.8 FCC Statement, Applicable in U.S. Technical Data 14.1 Angle Measurement 14.2 Distance Measurement with Reflectors 14.3 Distancer, Measurements without Reflectors (Reflectorless mode) 14.4 Distance Measurement Reflector (Long Range) 14.5 Conformity to National Regulations 14.5.1 Zoom 20  14.5.2 Zoom 30  14.6 General Technical Data of the Instrument 14.7 Scale Correction 14.8 Reduction Formulas Standard Limited Warranty Glossary Appendix A Menu Tree Appendix B Directory Structure Index...
  • Page 6: Description Of The System

    R6, Description of the System 1 Description of the System System Components Main Components a) R6 instrument b) Computer with GGO or GGO  Tools software c) Data transfer Zoom_001 Component Description R6 instrument An instrument for measuring, calculating and capturing data. Ideally suited  for tasks from simple surveys to complex applications. The various lines have a range of accuracy classes and support different  features. All lines can be connected with GGO or GGO Tools to view,  exchange and manage data. Firmware The firmware package installed on the instrument. Consists of a standard  base operating system with optional additional features. GGO or GGO  An office software consisting of a suite of standard and extended programs  Tools software for the viewing, exchanging, managing and post processing of data. Data transfer Data can be always transferred between a R6 instrument and a computer via  a data transfer cable. For Zoom 30 instruments data can also be transferred via USB memory stick  or Bluetooth.
  • Page 7: Container Contents

    R6, Description of the System Container Contents Container contents part 1 of 2 a) Instrument with supplied tribrach b) ZDC100 data cable (USB‐RS232)* c) Protective cover * Optional Zoom_022a Container contents part 2 of 2 a) Adjustment tools b) ZBA200 battery charger* c) USB memory stick ‐ for Zoom 30 instruments* d) ZBA400 battery* e) Tip for mini prism pole* f) User manual g) GLS115 mini prism pole* * Optional Zoom_022...
  • Page 8: Instrument Components

    R6, Description of the System Instrument Components Instrument components part 1 of 2 a) Detachable carrying handle with mounting screw b) Optical sight c) Objective with integrated Electronic Distance Meas‐ urement (EDM). Exit for EDM laser beam d) Vertical drive e) Serial interface RS232/USB f) USB host port g) Horizontal drive h) Second keyboard* * Optional e f g Zoom_002 Instrument components part 2 of 2 i) Focusing telescope image j) Eyepiece; focusing graticule k) Battery cover l) Foot screw m)Circular level n) Display o) Keyboard Zoom_003...
  • Page 9: User Interface

    R6, User Interface 2 User Interface Keyboard Alphanumeric keyboard a) Alphanumeric keypad b) Navigation key c) ENTER key d) Function keys F1 to F4 e) ESC key f) FNC key g) PAGE key Zoom_009 Keys Description Page key. Displays the next screen when several screens are available. FNC key. Quick‐access to measurement supporting functions. Navigation key. Controls the focus bar within the screen and the entry bar within a  field. ENTER key. Confirms an entry and continues to the next field. ESC key. Quits a screen or edit mode without saving changes. Returns to next higher  level. Function keys that are assigned the variable functions displayed at the bottom of the  screen. Alphanumeric keypad for entry of text and numerical values. Screen Screen a) Title of screen b) Focus in screen. Active field c) Status icons d) Fields e) Softkeys...
  • Page 10: Status Icons

    R6, User Interface All shown screens are examples. It is possible that local firmware versions are  different to the basic version. Status Icons Description The icons provide status information related to basic instrument functions. Depending on the  firmware version, different icons are displayed. Icons Icon Description The battery symbol indicates the level of the remaining battery capacity, 75% full  shown in the example. Compensator is on. Compensator is off. IR EDM mode for measuring to prisms and reflective targets. RL EDM mode for measuring to all targets. Offset is active. Keypad is set to numeric mode. Keypad is set to alphanumeric mode. Indicates that horizontal angle is set to left side angle measurement (anticlock‐ wise). A double arrow indicates a field has a selectable list. Up and down arrows indicate that several screens are available, which are  accessed using   . Indicates telescope position is face I. Indicates telescope position is face II. Bluetooth is connected. If there is a cross beside the icon, the Bluetooth commu‐ nication port is selected, but the status is inactive. USB communication port is selected.
  • Page 11: Softkeys

    R6, User Interface Softkeys Description Softkeys are selected using the relevant F1 to F4 function key. This chapter describes the func‐ tionality of the common softkeys used by the system. The more specialised softkeys are  described where they appear in the application chapters. Common softkey functions Description To change the keypad operation to alphanumerical. ALPHA To change the keypad operation to numerical. To start distance and angle measurements and save the measured values. To return to the last active screen. BACK To open the manual coordinate entry screen. COORD To view and change EDM settings. Refer to "4.2 EDM Settings". To exit the screen or application. EXIT To start distance and angle measurements without saving the measured values. MEAS If entry screen: Confirms measured or entered values and continues the  process. If message screen: Confirms message and continues with selected action or  returns to the previous screen to reselect an option. To toggle between IR and RL EDM modes. IR/RL To display the list of available points. DISPL. To save the displayed values. To reset all editable fields to their default values. DEFLT To search for an entered point. SEARCH To display the coordinate and job details of the selected point. VIEW To display the next softkey level. Operating Principles Turn instrument on/off Use the On/Off key.
  • Page 12: Pointsearch

    R6, User Interface Alphanumeric keypad The alphanumerical keypad is used to enter characters directly into editable fields. • Numeric fields: Can only contain numerical values. By pressing a key of the keypad the  number will be displayed. • Alphanumeric fields: Can contain numbers and letters. By pressing a key of the keypad  the first character written above that key will be displayed. By pressing several times you  can toggle through the characters. For example: 1‐>S‐>T‐>U‐>1‐>S..Edit fields ESC Deletes any change and restores the previous value. Moves the cursor to the left Moves the cursor to the right. Inserts a character at the cursor position. Deletes the character at the cursor position. In edit mode the position of the decimal place cannot be changed. The decimal place is skipped. Special characters Character Description Used as wildcards in search fields for point numbers or codes. Refer to "2.6  Pointsearch". +/‐ In the alphanumeric character set "+" and "‐" are treated as normal alphanu‐ meric characters with no mathematical function. "+" / "‐" only appear in front of an entry. In this example selecting 2 on an alphanumeric  keyboard would start the Set Out application. Pointsearch Description Pointsearch is a function used by applications to find measured or fixed points in the  memory  storage. It is possible to limit the point search to a particular job or to search the whole storage. The  search procedure always finds fixed points before measured points that fulfill the same search ...
  • Page 13 R6, User Interface criteria. If several points meet the search criteria, then the results are ordered according to the  entry date. The instrument finds the most recent fixed point first. Direct search By entering an actual point number, for example 402, and pressing SEARCH, all points within  the selected job and with the corresponding point number are found. SEARCH To search for matching points within the  selected job. Wildcard search The wildcard search is indicated by a "*". The asterisk is a place holder for any following  sequence of characters. Wildcards should be used if the point number is not fully known, or to  search for a batch of points. Examples of point searches All points are found. A All points with exactly the point number "A" are found. A* All points starting with "A" are found, for example, A9, A15, ABCD, A2A. *1 All points containing only one "1" are found, for example, 1, A1, AB1. A*1All points starting with "A" and containing only one "1" are found, for example, A1, AB1,  A51.
  • Page 14: Operation

    R6, Operation 3 Operation Instrument Setup Description This topic describes an instrument setup over a marked ground point using the laser plummet.  It is always possible to set up the instrument without the need for a marked ground point. Important features • It is always recommended to shield the instrument from direct sunlight and avoid uneven  temperatures around the instrument. • The laser plummet described in this topic is built into the vertical axis of the instrument.  It projects a red spot onto the ground, making it appreciably easier to centre the instru‐ ment. • The laser plummet cannot be used with a tribrach equipped with an optical plummet. Tripod When setting up the tripod pay attention to  ensuring a horizontal position of the tripod plate.  Slight corrections of inclination can be made with  the foot screws of the tribrach. Larger corrections  must be done with the tripod legs. Loosen the clamping screws on the tripod legs, pull out to the  required length and tighten the clamps. a) In order to guarantee a firm foothold sufficiently press the  tripod legs into the ground.  b) When pressing the legs into the ground note that the force  must be applied along the legs. Careful handling of tripod. • Check all screws and bolts for correct fit. • During transport always use the cover supplied. • Use the tripod only for surveying tasks.
  • Page 15 R6, Operation Setup step­by­step Zoom_004 1 Extend the tripod legs to allow for a comfortable working posture. Position the tripod over  the marked ground point, centring it as best as possible. 2 Fasten the tribrach and instrument onto the tripod. 3 Turn on the instrument, and, if tilt correction is set to 1‐ or 2‐axis, the laser plummet will be  activated automatically, and the Level & Plummet screen appears. Otherwise, press FNC  from within any application and select Level & Plummet. 4 Move the tripod legs (1) and use the tribrach footscrews (6) to center the plummet (4) over  the ground point. 5 Adjust the tripod legs (5) to level the circular level (7). 6 By using the electronic level, turn the tribrach footscrews (6) to precisely level the instru‐ ment. Refer to "Level up with the electronic level step‐by‐step". 7 Center the instrument precisely over the ground point by shifting the tribrach on the tripod  plate (2). 8 Repeat steps 6 and 7 until the required accuracy is achieved. Level up with the electronic level step­by­step The electronic level can be used to precisely level up the instrument using the footscrews of the  tribrach. Turn the instrument until it is parallel to two footscrews. Center the circular level approximately by turning the footscrews of the tribrach. Turn on the instrument, and, if tilt correction is set to 1‐ or 2‐axis, the laser plummet will  be activated automatically, and the Level & Plummet screen appears. Otherwise, press  FNC from within any application and select Level & Plummet. The bubble of the electronic level and the arrows for the rotating direction of ...
  • Page 16: Working With The Battery

    R6, Operation When the electronic level is centered and three  checkmarks are shown, the instrument has been  perfectly levelled up. 6 Accept with OK. Change the intensity of the laser plummet External influences and the surface conditions may require the adjustment of the intensity of  the laser plummet. In the Level & Plummet screen, adjust the  intensity of the laser plummet using the naviga‐ tion key. The laser can be adjusted in 25% steps as  required. Position over pipes or holes Under some circumstances the laser dot is not  visible, for example over pipes. In this case,  using a transparent plate enables the laser dot to  be seen and then easily aligned to the center of  the pipe. Zoom_005 Working with the Battery Charging / first­time use • The battery must be charged prior to using it for the first time because it is delivered with  an energy content as low as possible. • For new batteries or batteries that have been stored for a long time (> three months), it is  effectual to make only one charge/discharge cycle. • The permissible temperature range for charging is between 0°C to +40°C/+32°F to  +104°F. For optimal charging we recommend charging the batteries at a low ambient  temperature of +10°C to +20°C/+50°F to +68°F if possible. • It is normal for the battery to become warm during charging. Using the chargers recom‐ ® mended by Stonex , it is not possible to charge the battery if the temperature is too high.
  • Page 17: Data Storage

    R6, Operation Operation / discharging • The batteries can be operated from ‐20°C to +50°C/‐4°F to +122°F. • Low operating temperatures reduce the capacity that can be drawn; very high operating  temperatures reduce the service life of the battery. • For Li‐Ion batteries, a single discharging and charging cycle is sufficient. We recommend  carrying out the process when the battery capacity indicated on the charger or on a  ® Stonex  product deviates significantly form the actual battery capacity available. Change the battery step­by­step Open the battery compartment (1) and remove the  battery holder. Remove the battery from the battery holder (2). Zoom_006 Insert the new battery into the battery holder (3),  ensuring that the contacts are facing outward. The  battery should click into position. Insert the battery holder back into the battery compart‐ ment (4). Zoom_007 The polarity of the battery is displayed inside the battery housing. Warning ® If charged or discharged, batteries not recommended by Stonex  may be damaged. They may  burn and explode. Precautions: ® Only charge and discharge batteries recommended by Stonex Data Storage Description An internal memory is included in all instruments. The firmware stores all data in jobs in a data‐ base in the internal memory.  Data can then be transferred to a computer or other device for  post processing via a cable connected to the serial interface RS232 port. For Zoom 30 instruments, data can also be transferred from the internal memory to a computer  or other device via: •...
  • Page 18: Main Menu

    R6, Operation Refer to "10 Data Management" for further information on data management and data transfer. Main Menu Description The MAIN MENU is the starting place for accessing all functionality of the instrument. It is  usually displayed immediately after the Level & Plummet screen, after switching on the  instrument. MAIN MENU Description of the MAIN MENU functions Function Description To select and start applications. Refer to "9 Applications". Apps To manage jobs, data, codelists, formats, system memory and USB memory  Data stick files. Refer to "10 Data Management". To change EDM configurations, comm.‐setup and general instrument settings.  Settings Refer to "4 Settings". Survey Survey program to begin measuring immediately. Refer to "3.5 Survey Appli‐ cation". To export and import data. Refer to "10.2 Exporting Data". Transfer To access instrument related tools such as calibrations, personal start up  Tools settings, licence keys and system information. Refer to "5 Tools". If desired, the instrument can be configured to start in a user defined place after the Level & Plummet screen, instead of the MAIN MENU. Refer to "5.2 Auto Start Routine". Survey Application Description After switching on and setting up correctly, the instrument is immediately ready for measuring.
  • Page 19: Distance Measurements - Guidelines For Correct Results

    R6, Operation Access Select Survey from the MAIN MENU. SURVEY CODING To find/enter codes. Refer to "7 Coding". To enter station data and set the station. Set HA To set the horizontal direction orientation. / HA To set the horizontal angle reading to the left (anti‐ clockwise) or to the right (clockwise). The procedure for the quick start Survey is identical to the procedure for the application  Survey available under the Apps menu. Therefore this procedure is only described once  within the application chapter. Refer to "9.2 Survey". Distance Measurements ­ Guidelines for Correct Results Description A laser distancer (EDM) is incorporated into the R6 instruments. In all versions, the distance can  be determined by using a visible red laser beam which emerges coaxially from the telescope  objective. There are two EDM modes: • Prism measurements (IR) • Reflectorless measurements (RL) RL measurements • When a distance measurement is triggered, the EDM measures to the object which is in the  beam path at that moment. If a temporary obstruction, for example a passing vehicle,  heavy rain, fog or snow is between the instrument and the point to be measured, the EDM  may measure to the obstruction. • Be sure that the laser beam is not reflected by anything close to the line of sight, for  example highly reflective objects.
  • Page 20 R6, Operation • Avoid interrupting the measuring beam while taking reflectorless measurements or  measurements using reflective foils. • Do not measure with two instruments to the same target simultaneously. IR measurements • Accurate measurements to prisms should be made in IR‐Default mode. • Measurements to strongly reflecting targets such as traffic lights in Prism mode without a  prism should be avoided. The measured distances may be wrong or inaccurate. • When a distance measurement is triggered, the EDM measures to the object which is in the  beam path at that moment. If for example people, cars, animals, or swaying branches cross  the laser beam while a measurement is being taken, a fraction of the laser beam is  reflected from these objects and may lead to incorrect distance values. • Measurements to prisms are only critical if an object crosses the measuring beam at a  distance of 0 to 30 m and the distance to be measured is more than 300 m. • In practice, because the measuring time is very short, the user can always find a way of  avoiding unwanted objects from interferring in the beam path. Red laser to prism • RL‐Long Range mode enables distance measurements of over 3.5 km to standard prisms  using the visible red laser beam. Red laser to reflector foil • The visible red laser beam can also be used to measure to reflective foils. To guarantee the  accuracy the red laser beam must be perpendicular to the reflector foil and it must be well  adjusted. • Make sure the additive constant belongs to the selected target (reflector).  Warning Due to laser safety regulations and measuring accuracy, using the Long Range Reflectorless  EDM is only allowed to prisms that are more than 1000 m (3300 ft) away.
  • Page 21: Settings

    R6, Settings 4 Settings General Settings Access  Select Settings from the MAIN MENU.  Select General from the SETTINGS menu.  Press   to scroll through the screens of available settings. SETTINGS DelLng To delete a selected language. Field Description Sets the display contrast in 10% steps. Contrast 0% to 100% Tilting compensation deactivated. Tilt Corr. Vertical angles refer to the plummet line. Single Axis Vertical angles refer to the plummet line and the horizontal  Dual Axis directions are corrected by the standing axis tilt. For corrections depending on the HA Corr: setting, refer to  the table "Tilt and horizontal corrections". If the instrument is used on an unstable base, for example a shaking platform  or ship, the compensator should be deactivated. This avoids the compensator  drifting out of it's measuring range and interrupting the measuring process by  indicating an error. Horizontal corrections are activated. For normal operation  HA Corr. the horizontal correction should remain active. Each meas‐...
  • Page 22 R6, Settings Field Description Sets face I to be when the vertical drive is on the right of the  VA-Right instrument. Set horizontal angle to clockwise direction measurement. HA Incr. Right Set horizontal angle to counter‐clockwise direction meas‐ Left urement. Counter‐clockwise directions are displayed but are  saved as clockwise directions. Sets the vertical angle. VA-Setting Zenith Zenith=0°; Horizon=90°.  Horizont Zenith=90°; Horizon=0°.  Vertical angles are positive above the horizon  and negative below it.  Slope % 45°=100%; Horizon=0°.  Slope % +300 % Vertical angles are expressed in % with  --.--% +100% positive above the horizon and negative  +18 % below it. 360s 0° ±VA The % value increases rapidly.  ‐‐.‐‐%  appears on the display above 300%.
  • Page 23 R6, Settings Field Description Dec.deg: (0.0001 / 0.0005 / 0.001). Gon: (0.0001 / 0.0005 / 0.001). Mil: (0.01 / 0.05 / 0.1). Sets the units shown for all distance and coordinate related fields. Dist. Unit Meters [m]. meter US feet [ft]. ft (US) International feet [fi]. ft (INT) US feet‐inch‐1/16 inch [ft]. ft-in/16 Sets the units shown for all temperature fields. Temp. Unit Degree Celsius. °C Degree Fahrenheit. °F Sets the units shown for all pressure fields. Press.Unit Hecto Pascal. Millibar. mbar Millimeter mercury. mmHg Inch mercury. inHg The beep is an acoustic signal after each key stroke. Beep Normal volume.
  • Page 24 R6, Settings Field Description The display heater is activated. Heating The display heater is deactivated. The display heater is automatically activated when the display illumination is  on and the instrument temperature is  5°C. Data Output Sets the location for data storage. All data is recorded in the internal memory. Int. Mem. Data is recorded via the serial interface or the USB device  Interface port, depending on the port selected in the COMMUNICA- TION SETTINGS screen. This Data Output setting is only  required if an external storage device is connected and meas‐ urements are started at the instrument with MEAS/REC or  ALL. This setting is not required if the instrument is totally  controlled by a datalogger. Sets the GSI output format. GSI Format 81..00+12345678 GSI 8 81..00+1234567890123456 GSI 16 Sets the GSI output mask. Mask Pt, HA, VA, sDIST, ppm+mm, TgtHGT, Instr.h. Mask1 Pt, HA, VA, sDIST, E, N, H, TgtHGT. Mask2 Code saving Sets if the codeblock is saved before or after the measurement. Refer to "7 ...
  • Page 25: Edm Settings

    R6, Settings Tilt and horizontal corrections Setting Correction Tilt correc­ Horizontal  Incline longi­ Incline trans­ Horizontal  Tilting axis tion correction tudinal versal collimation 1-Axis 2-Axis 1-Axis 2-Axis EDM Settings Description The settings on this screen define the active EDM, Electronic Distance Measurement. Different  settings for measurements are available with Recflectorless (RL) and Prism (IR) EDM modes. Access Select Settings from the MAIN MENU. Select EDM from the SETTINGS menu. EDM SETTINGS ATMOS To enter atmospheric data ppm. To enter an individual ppm value. SCALE To enter projection scale details. SIGNAL To view EDM Signal reflection value. FREQ. To view the EDM frequency. Field Description Fine measuring mode for high precision measurements with ...
  • Page 26 Custom Constants can be entered in mm in GeoMax Const: GeoMax Constant: +34.4 mm Foil GeoMax Constant: +34.4 mm None RL-modes This field displays the GeoMax prism constant for the selected Type: GeoMax Where Type: is Custom this field becomes editable to set a user defined  Const. constant. Input can only be made in mm.  Limit value: ‐999.9 mm to +999.9 mm. Visible laser beam is deactivated. Laser-Beam Off Visible laser beam for visualising the target point is activated. ATMOSPHERIC DATA ENTRY This screen enables the entry of atmospheric parameters. Distance measurement is influenced  directly by the atmospheric conditions of the air in which the measurements are taken. In order  to take these influences into consideration distance measurements are corrected using atmos‐ pheric correction parameters. The refraction correction is taken into account in the calculation of the height differences and  the horizontal distance. Refer to "14.7 Scale Correction" for the application of the values entered  in this screen. ® When PPM=0 is selected, the Stonex  standard atmosphere of 1013.25 mbar, 12°C,  and 60% relative humidity will be applied. PROJECTION SCALE This screen enables entry of the scale of projection. Coordinates are corrected with the PPM  parameter. Refer to "14.7 Scale Correction" for the application of the values entered in this  screen.
  • Page 27: Communication Settings

    R6, Settings Free­PPM Entry This screen enables the entry of individual scaling factors. Coordinates and distance measure‐ ments are corrected with the PPM parameter. Refer to "14.7 Scale Correction" for the applica‐ tion of the values entered in this screen. EDM SIGNAL REFLECTION This screen tests the EDM signal strength (reflection strength) in steps of 1%. Enables optimal  aiming at distant, barely visible, targets. A percentage bar and a beeping sound, indicate the  reflection strength. The faster the beep the stronger the reflection. Communication Settings Description For data transfer the communication parameters of the instrument must be set. Access Select Settings from the MAIN MENU. Select Comm from the SETTINGS menu. COMMUNICATION SETTINGS BTCode To set a code for the Bluetooth connection. This softkey is only available for Zoom 30  instruments. The default Bluetooth code is  ’0000’. Field Description Instrument port. For Zoom 30 instruments, the options are selectable. For Zoom  Port 20 instruments, the value is set to RS232 and is uneditable. Communication is via the serial interface. RS232 Communication is via the USB host port. Communication is via Bluetooth. Bluetooth Communication is set to auto detect. Automatically Bluetooth sensor is activated. Bluetooth Bluetooth sensor is deactivated. The following fields are active only when Port: RS232 is set.
  • Page 28 R6, Settings Field Description Speed of data transfer from receiver to device in bits per second. Baudrate 1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200 Number of bits in a block of digital data. Databits Data transfer is realised with 7 databits. Data transfer is realised with 8 databits. Even parity. Available if data bit is set to 7. Parity Even Odd parity. Available if data bit is set to 7. No parity. Available if data bit is set to 8. None The terminator is a carriage return followed by a line feed. Endmark CR/LF The terminator is a carriage return. Number of bits at the end of a block of digital data. Stopbits...
  • Page 29: Tools

    R6, Tools 5 Tools Calibration Description The CALIBRATION menu contains tools to be used for the electronic calibration of the instru‐ ment. Using these tools helps to maintain the measuring accuracy of the instrument. Access Select Tools from the MAIN MENU. Select Calibr. from the TOOLS MENU. Select a calibration option from the CALIBRATION screen. Calibration options In the CALIBRATION screen there are several calibration options. Menu selection Description HA-Collimation Refer to "11.3 Calibrating Line‐of‐Sight and Vertical Index Error". Refer to "11.3 Calibrating Line‐of‐Sight and Vertical Index Error". Vertical Index Displays the current calibration values that have been set for HA‐Collima‐ View Calibration tion and V‐index. Data Auto Start Routine Description Through the Auto Start tool, it is possible to record a user defined sequence of key presses so  that, after switching on the instrument, a particular screen can be displayed after the Level & Plummet screen instead of the MAIN MENU. For example, the general SETTINGS screen for  configuring the instrument settings. Access Select Tools from the MAIN MENU. Select Auto St. from the TOOLS MENU. Auto start step­by­step Press REC in the AUTO START screen.
  • Page 30: System Information

    R6, Tools The next key presses are stored, up to a maximum of 16. To end the recording press ESC. If the auto start Status: is set to On, the stored key presses will be executed automatically  after switching on the instrument. The automatic start routine has the same effect as pressing the keys manually. Certain instru‐ ment settings can not be made in this way. Relative entries such as automatically setting EDM Mode: IR-Quick upon switching on the instrument, are not possible. System Information Description The System information screens display instrument, system and firmware information, as well  as settings for the date and time. Access Select Tools from the MAIN MENU. Select SysInfo from the TOOLS MENU. SYSTEM INFORMATION This screen displays information about the instrument and operating system. Firmw. To display details of the firmware package installed  on the instrument. DATE To change the date and format. TIME To change the time. Next step Press Firmw. to view the firmware package information. SOFTWARE­INFORMATION Before selecting FORMAT, to format the internal memory, ensure that all important  data is first transferred to a computer. Jobs, formats, codelists, configuration files,  uploaded languages and firmware will be deleted by formatting. Field Description Displays the firmware version number installed on the instrument. Zoom-FW. Versi Displays the build number of the firmware. Build Displays the current language and version number selected for the ...
  • Page 31: Loading Software

    R6, Tools Field Description Displays the version number of the EDM firmware. EDM-Firmware Displays a list of the applications available on the instrument. Application Information Loading Software Description To load application software or an additional language, connect the instrument to GGO via the  serial interface and load using "GGO ‐ Software Upload". Refer to the GGO online help for further  information.  For Zoom 30 instruments, the software can be loaded via a USB memory stick. This process is  described below. Access Select Tools from the MAIN MENU. Select Load FW from the TOOLS MENU. • Load FW is only an option on the TOOLS MENU for Zoom 30 instruments. • Never disconnect the power supply during the system upload process. The battery must  be at least 75% capacity before commencing the upload. Loading firmware and languages step­by­step To load firmware and languages: Select Zoom Firmware. The Select File screen will  appear. To load only languages: Select Zoom Languages only and skip to step 4 2 Select the firmware file from the system folder of the USB memory stick. All firmware and  language files must be stored in the system folder to be transferred to the instrument. 3 Press OK.
  • Page 32: Functions

    R6, Functions 6 Functions Overview Description Functions can be accessed by pressing FNC from any measurement screen. FNC opens the  functions menu and a function can be selected and activated. Functions Function Description Activates the laser plummet and electronic level. Level & Plummet Refer to "6.2 Distance Offset". Distance Offset Changes between the two EDM modes. Refer to "4.2 EDM Settings". RL/IR Change Deletes the last recorded data block. This can be either a measure‐ Delete Last Observ. ment block or a code block. Deleting the last record is not reversible! Only records  recorded in Survey can be deleted. Starts Coding application to select a code from a codelist or enter a  Code-Library new code. Same functionality like the softkey CODING. Activates/deactivates the visible laser beam for illuminating the  Laserbeam target point. Activates and deactivates the screen illumination light. Screen ill. On /Off Sets the distance measurement unit. Distance unit Sets the angle measurement unit.
  • Page 33: Distance Offset

    R6, Functions Distance Offset Description This function calculates the target point coordinates if it is not possible to set up the reflector,  or to aim at the target point directly. The offset values (length, trav. and/or height offset) can be  entered. The values for the angles and distances are calculated to determine the target point. T_Off - L_Of L_Off - T_Off+ Measurement point Offset point T_Off Length offset L_Off Cross offset Access Press FNC when within any application. Select Distance Offset from the FUNCTIONS menu. DIST­OFF DEFLT To reset offset values to 0. Field Description Perpendicular offset. Positive if the offset point is to the right of the measured  Trav. point. Offset Longitudinal offset. Positive if the offset point is further away than the meas‐ Length ured point. Offset Height offset. Positive if the offset point is higher than the measured point. Z-Offset Period for which the offset is to apply. Mode The offset values are reset to 0 after the point is saved. 0 after REC The offset values are applied to all further measurements.
  • Page 34: Z-Coordinate

    R6, Functions Next step • Press OK to calculate the corrected values and return to the application from which the  offset function was started. The corrected angle and distances are displayed as soon as a  valid distance measurement has been triggered or exists. Z­Coordinate Description This function determines the height of the instrument from measurements to a maximum of five  target points, with known heights, in two faces. With measurements to several targets, the improvement is indicated in the "d"  value. 1 Reflector 1 2 Reflector 2 3 Reflector 3 4 Instrument STn.Z Access Press FNC when within any application. Select Z-Coordinate from the FUNCTIONS menu. Z­Coordinate step­by­step Select a known point and input the reflector height. Select; • PtHgt: To enter the height of a fixpoint. • Inst.h.: To enter the height transfer values for the instrument. Press ALL to complete the measurement and display the calculated height. • AddTg: Adds another height of a known point. • FACE: Measures to the same target in second face. • OK: Saves the changes and sets the station height. 2 Dist. Offset Description This function is used for measurements to a point that is not directly visible, using a special 2  Dist. Offset pole.
  • Page 35 R6, Functions E, N, H of Target Point Pole Length Distance P1‐P2 Access Press FNC when within any application. Select 2 Dist. Offset from the FUNCTIONS menu. Next step If required, press POLE to define the pole or EDM settings. POLE SETTINGS Field Description Changes the EDM Mode. Mode Changes the prism type. Type Displays the prism constant. GeoMax Const Total length of 2 Dist. Offset pole Pole Length Spacing between the centers of the prisms P1 and P2. Dist. P1-P2 Limit for the difference between the given and measured spacing of the  Meas. Tol prisms. If the tolerance value is exceeded, the function will issue a warning. Next step In the 2 DIST. OFFSET screen, measure to the first and second prisms using ALL and the 2 DIST. OFFSET RESULT screen is displayed. 2 DIST. OFFSET RESULT Displays Easting, Northing and Height coordinates of the target point.
  • Page 36: Control Distance

    R6, Functions Next step Press END to return to the application where FNC was selected. Control Distance Description This function calculates and displays the slope and horizontal distance, height difference,  azimuth, grade, and coordinate differences between the last two measured points. Valid  distance measurements are required for the calculation. Azi Azimuth SD Slope distance VD Height distance HD Horizontal distance Access Press FNC when within any application. Select Control Distance from the FUNCTIONS menu. CONTROL DISTANCE Field Description Difference in bearing between the two points. Difference in gradient between the two points. Grade Difference in horizontal distance between the two points. hDIST Difference in slope distance between the two points. sDIST Difference in height between the two points. d.d.Z Messages The following are important messages or warnings that may appear. Messages Description The values cannot be calculated as there are less than two valid  Less than two valid measurements.
  • Page 37: Edm Continuous

    R6, Functions Next step Press OK to return to the application where FNC was selected. EDM Continuous Description This function activates or deactivates the tracking measurement mode. The new setting is  displayed for about one second and then set. The function can only be activated from within the  same EDM mode and prism type. The following options are available. Mode Off <=> On IR‐Default <=> IR‐Continuous / IR‐Quick <=> IR‐Continuous. RL‐Default <=> RL‐Continuous. The last active measurement mode remains set when the instrument is switched off.
  • Page 38: Coding

    R6, Coding 7 Coding Description Codes contain information about recorded points. With the help of coding, points can be  assigned to a particular group simplifying later processing. Codes are stored in codelists, with each codelist supporting a maximum of 200 codes. GSI coding Codes are always stored as free codes (WI41‐49), that means that codes are not directly linked  to a point. They are stored before or after the measurement depending on the setting made.  Point codes (WI71‐79) are not available. A code is always recorded for each measurement as long as the code is displayed in the Code:  field. For a code not to be recorded, the Code: field must be cleared. This can be set to occur  automatically. Refer to "4.1 General Settings". Access • Either, select Survey from the MAIN MENU and press  CODING. • Or, press FNC when within any application and select Code Library. CODE­LIBRARY To record the code without measurement. AddLst To add the entered code to the codelist. Field Description Code name. Search/New After entry, the firmware searches for a matching code name, and displays  these in the code field. If a matching code name doesn’t exist this value  becomes the new code name. List of existing code names. Code Additional remarks. Comment Text1 to More information lines, freely editable. Used to describe attributes of the ...
  • Page 39 R6, Coding The codelist editor of GGO can assign a status to the attributes. • Attributes with status "fixed" are write‐protected. They cannot be overwritten or edited. • For attributes with status "Mandatory" an input or a confirmation is required. • Attributes with status "Normal" can be edited freely.
  • Page 40: Applications ­ Getting Started

    R6, Applications - Getting Started 8 Applications ­ Getting Started Overview Description Applications are predefined programs, that cover a wide spectrum of surveying duties and facil‐ itate daily work in the field. The following applications are available, although application pack‐ ages for each instrument may vary from that stated below: • Survey • Reference Element • COGO • Missing Line Measurement • Resection • Set Out • Area & Volume • Remote Elevation • Construction Starting an Application Access Select Apps from the MAIN MENU. Press   to move through the screens of available applications. Press a function key, F1 ‐ F4, to select the specified application in the APPS menu. Pre­settings screens Pre‐settings for Survey is shown as an example. Any additional settings for particular applica‐ tions are explained within the chapters for those applications. [ • ] = Setting has been made. ] = Setting has not been made.
  • Page 41: Selecting The Job

    R6, Applications - Getting Started Field Description Starts the selected application. Selecting the Job Description All data is saved in Jobs, like file directories. Jobs contain measurement data of different types,  for example measurements, codes, fixed points, or stations. Jobs are individually manageable  and can be exported, edited or deleted separately. Access Select Select Job in Pre-settings screen. SELECT JOB To create a new job. Field Description Name of an existing job to be used. Name of user, if entered. User Date the selected job was created.  Date Time the selected job was created.  Time Next step • Either, press OK to continue with the selected job. • Or, press NEW to open the NEW JOB screen and create a new job. Recorded data Once a job is set up, all subsequent recorded data will be stored in this job. If no job was defined and an application was started, or if in Survey and a measurement was  recorded, then the system automatically creates a new job and names it "DEFAULT". Next step Press OK to confirm the job and return to the Pre-Settings screen.
  • Page 42: Selecting The Station

    R6, Applications - Getting Started Selecting the Station Description All measurements and coordinate computations are referenced to the set station coordinates. The station coordinates that are set must include: • at least grid coordinates (E, N), and • the station height, if required.  The coordinates can be entered manually or selected from the memory. Directions Easting Northing Height Station coordinates STn.X STn.Y Stn.X Easting coordinate of station Stn.Y Northing coordinate of station Access Select Select Station in the Pre-settings screen. Station input Field Description Station name of a previously saved station position. If no station was set and an application was started, or if in Survey and a measurement was  recorded, then the last station is set as the current station. Next step The Inst.H. field appears once the station coordinates have been entered. Enter the instrument  height if desired and press OK to return to the Pre-Settings screen. Selecting the Orientation 8.5.1 Overview Description All measurements and coordinate computations are referenced to the orientation of the set ...
  • Page 43: Manual Orientation

    R6, Applications - Getting Started Access Select Select Orientn. in the Pre-settings screen and choose: • Angle  To enter a new bearing. Refer to "8.5.2 Manual Orientation". • Coordinates To calculate and set the orientation using existing coordinates.  A  maximum of five target points can be used. Refer to "8.5.3 Orientation with Coordi‐ nates". 8.5.2 Manual Orientation Access Select Angle in the STN.ORIENTATION screen. MANUAL ANGLE SETTING HA=0 To set Brg: 0 Field Description Horizontal direction of the station. Height of the reflector. TgtHGT. Point ID of the backsight point. BS ID Next step • Either, press ALL to measure and record the distance and horizontal angles. This will  calculate and set the orientation and return to the Pre-Settings screen. • Or, press REC to record the horizontal direction only. This will set the orientation and  return to the Pre-Settings screen. 8.5.3 Orientation with Coordinates Diagram Known coordinates...
  • Page 44 R6, Applications - Getting Started Access Select Coordinates in the STN-ORIENTATION screen. Orientation with coordinates Field Description Point ID of the backsight point. Next step Find an existing backsight point in the pointsearch or enter ENZ coordinates for a new point.  Press OK to continue to Sight target point. Sight target point Field Description Point ID of the selected, or entered backsight point. BS ID Next step After each measurement the message, Do you want to take additional measurements  appears. Selecting: • Yes returns to the Sight target point screen to take an additional measurement. A  maximum of five target points can be used. • No proceeds to the STN. ORIENTATION RESULT screen. Result calculation If more than one target point is measured then the orientation is computed using the "least ...
  • Page 45 R6, Applications - Getting Started Field Description Standard deviation indicating the potential variance between the true orienta‐ Std.Dev tion and that calculated. Next step • Either, press Resid to display the residuals. • Or, press OK to set the orientation and return to the Pre-Settings screen. Stn. Orientation Residuals Actual Design Target point d Offs Height correction d HD Correction in horizontal distance d HA(+) d HA Correction in horizontal direction Field Description Point IDs of the target points used in calculating the orientation. BS ID The difference in horizontal direction to the target point. d.H.A The difference in horizontal distance to the target point. d.H.D The difference in height to the target point. If no orientation was set and an application was started, or if in Survey and a measurement was  recorded, then the current horizontal direction is set as the orientation. Next step Select GO! to begin the application.
  • Page 46: Applications

    R6, Applications 9 Applications Common Fields Description of fields The following table describes common fields that are found within the firmware applications.  These fields are described here once and not repeated in the application chapters unless the  field has a specific meaning within that application. Field Description Point ID of the point. Pt, Pt 1 Height of the reflector. TgtHGT Horizontal direction to the point. Vertical angle to the point. Horizontal distance to the point. hDIST Slope distance to the point. sDIST Height to the point. dHGT Easting coordinate of the point. Northing coordinate of the point. Height coordinate of the point. Survey Description Survey is an application used for the measurement of an unlimited number of points. It is  comparable to Survey from the MAIN MENU, but includes pre‐settings for the job, station and  orientation prior to beginning a survey. Access Select Apps from the MAIN MENU. Select Survey from the APPS menu. Complete application pre‐settings. Refer to "8 Applications ‐ Getting Started".
  • Page 47: Reference Element - Reference Line

    R6, Applications SURVEY I Pt To switch between individual and current point  numbers. CODING To find/enter codes. Refer to "7 Coding". Field Description Comment or Code name depending on the coding method. Two coding methods  Comment / are available: Code Comment coding: This text is stored with the corresponding measure‐ ment. The code is not related to a codelist, it is just a simple comment. A  codelist on the instrument is not necessary. Expanded coding with codelist: Press  CODING. The code that was  entered is searched for within the code list and it is possible to add  attributes to the code. Next step • Either, press ALL to record another point. • Or, press ESC to exit the application. Reference Element ­ Reference Line 9.3.1 Overview Description Reference Element ‐ Line is an application that facilitates the easy set out or checking of lines,  for example, for buildings, sections of road, or simple excavations. It allows the user to define a  reference line and then complete the following tasks with respect to that line: • Line & offset • Set out points Access Select Apps from the MAIN MENU. Select Reference Element from the APPS menu.
  • Page 48: Defining The Base Line

    R6, Applications 9.3.2 Defining the Base Line Description A reference line can be defined by referencing a known base line. The reference line can be  offset either longitudinally, in parallel or vertically to the base line, or be rotated around the first  base point as required. Furthermore the reference height can be selected as the first point,  second point or interpolated along the reference line. Define the base line The base line is fixed by two base points. All points can be either measured, manually entered,  or selected from the memory. 1 1st base point 2 2nd base point 3 Base line 4 Reference line Define the base line by measuring or selecting the start and end points of the line. Next step After defining the base line the REFERENCE LINE screen will appear for defining the reference  line. 9.3.3 Defining the Reference Line Description The base line can be offset from, either longitudinally, in parallel or vertically, or be rotated  around the first base point. This new line created from the offsets is called the reference line. All  measured data refers to the reference line. Reference line BP Base point BL Base line RP Reference point RL Reference line Off Parallel offset Longitudinal offset R Rotation parameter...
  • Page 49: Subapplication Measure Line & Offset

    R6, Applications REFERENCE LINE To define a new base line. MEAS To measure Line & Offset. SETOUT To set out points orthogonal to the reference line. Field Description Length of the base line. Length Parallel offset of the reference line relative to the base line (P1‐P2). Offset Positive values are to the right of the base line. Longitudinal offset of the start point, reference point (P3), of the reference line  Line in the direction of base point 2. Positive values are towards base point 2. Height offset of the reference line to the selected reference height. Positive values are higher than the selected reference height. Rotation of the reference line clockwise around the reference point (P3). Rotate Height differences are computed relative to the height of the  Ref.Hgt Pt. 1 first reference point. Height differences are computed relative to the height of the  Pt. 2 second reference point. Interpolated Height differences are computed along the reference line. Height differences are not computed or shown. w/o. Height Next step Select a softkey option, MEAS or SETOUT to proceed to a subapplication. 9.3.4 Subapplication Measure Line & Offset Description The Measure Line & Offset subapplication calculates from measurements or coordinates, longi‐...
  • Page 50: Subapplication Setout

    R6, Applications RL Reference line 1RPStart point MP Measured point dL Longitudinal offset dOffParallel offset Example of height difference relative to first reference point 1RP1st reference point 1BP1st base point d Z+ RH Reference height d Z- Hd Height difference between reference and base point d Z Height difference from reference height Access Press MEAS in the REFERENCE LINE screen. Measure Field Description Calculated distance longitudinal to the reference line. d Line Calculated distance perpendicular from the reference line. d Offset Calculated height difference relative to the defined reference height. d.d.Z Next step • Either, press ALL to measure and record. • Or, press ...
  • Page 51 R6, Applications Example orthogonal setout 1RP1st reference point SP Set out point d L- MP Measured point RL Reference line d O- dL Longitudinal offset dO Parallel offset Access Press SETOUT from the REFERENCE LINE screen. SETOUT Enter the set out elements for the target points to be set out relative to the reference line. Field Description Longitudinal offset: Positive if set out point is further away from the reference  Line line. Perpendicular offset: Positive if set out point is to the right of the reference line. Offset Height offset: Positive if set out point is higher than the reference line. Next step Press OK to proceed to measurement mode. SET OUT The signs for the distance and angle differences are correction values (required minus actual).  The arrows indicate the direction to move to get to the set out point. NextPt To add the next point to be set out. Field Description Horizontal direction from the measured point to the set out point. Positive if the ...
  • Page 52: Reference Element - Reference Arc

    R6, Applications Field Description Height difference from the measured point to the set out point. Positive if the set  d.d.Z out point is higher than the measured point. Perpendicular distance from the measured point to the set out point. Positive if the  dOffset set out point is to the right of the measured point. Longitudinal distance from the measured point to the set out point. Positive if the  dLine set out point is further away than the measured point. Messages The following are important messages or warnings that may appear. Messages Description Base line too short ! Base line is shorter than 1 cm. Choose base points such that the hori‐ zontal separation of both points is at least 1 cm. Coordinates invalid ! No coordinates or invalid coordinates for a point. Ensure that points  used have at least Easting and Northing coordinates. Save via RS232 ! Data Output: is set to RS232 in the SETTINGS menu. To be able  to successfully start reference element, Data Output: must be set  to Internal. Next step •...
  • Page 53: Defining The Reference Arc

    R6, Applications Complete application pre‐settings. Refer to "8 Applications ‐ Getting Started". Select Arc. Next step Define the reference arc. 9.4.2 Defining the Reference Arc Description The reference arc can be defined by a center point and start point, or a start point, end point,  and radius. All points can be either measured, manually entered, or selected from the memory. SP Start point Off - EP End point CP Center point R Radius of arc Distance from start of arc, following curve Off Perpendicular distance from arc All arcs are defined in a clockwise direction and all calculations are made in two dimensions.  Access Select Arc and then the method to define the arc by: • Start-/ Centre Pt. • Start-/ End Pt/ Rad.  Reference Arc ­ Measure to start point Field Description Point ID of the start point. Start Pt Point ID of the center point.
  • Page 54: Subapplication Measure Line & Offset

    R6, Applications REFERENCE ARC To define a new base arc. MEAS To measure Line & Offset. SET OUT To set out. Next step Select a softkey option, MEAS or SET OUT, to proceed a subapplication. 9.4.3 Subapplication Measure Line & Offset Description The Measure Line & Offset subapplication calculates from measurements or coordinates, longi‐ tudinal and orthogonal offsets and height differences of the target point relative to the reference  arc. Access Press MEAS from the REFERENCE ARC screen. Measure Field Description Calculated distance longitudinal to the reference arc. dLine Calculated distance perpendicular from the reference arc. dOffset Calculated height difference relative to the start point of reference arc. d.d.Z Next step • Either, press ALL to measure and record. • Or, press  BACK to return to the REFERENCE ARC screen. 9.4.4 Subapplication Setout Description The setout subapplication calculates the difference between a measured point and the calcu‐...
  • Page 55 R6, Applications Set out point To set out a point by entering a line and an offset value. CP Center point of arc Off - SP Start point of arc EP End point of arc Set out point R Radius of arc Line offset Off Perpendicular offset Set out arc To set out a series of equidistant points along the arc. CP Center point of arc SP Start point of arc EP End point of arc Set out point(s) R Radius of arc AL Arc length Set out chord To set out a series of equidistant chords along the arc. CP Center point of arc SP Start point of arc EP End point of arc Set out point(s) R Radius of arc CL Chord length Set out angle To set out a series of points along the arc defined by the angle segments from the center point ...
  • Page 56 R6, Applications Set out point, arc, chord or angle Enter the set out values. Press PrevPt/NextPt to toggle through the calculated set out points. Field Description For set out arc: Method of misclosure distribution. If the entered arc length is  Distrib. not an integer of the whole arc, there will be a misclosure. All of the misclosure will be added to the last arc‐section. None The misclosure will be equally distributed between all sections. Equal All of the misclosure will be added to the first arc‐section. Start Arc Arc Length For set out arc: The length of the arc‐segment to set out. For set out chord: The length of the chord to set out. Chord Length For set out angle: The angle around the center point of the arc, of the points to  Angle be set out. For set out arc, chord and angle: Longitudinal offset from the reference arc. This  Line is calculated by the arc length, chord length or angle and the selected misclosure  distribution. For set out point: Longitudinal offset from the reference arc. Perpendicular offset from the reference arc. Offset Next step Press OK to proceed to measurement mode. REFERENCE ARC ­ SET OUT The signs for the distance and angle differences are correction values (required minus actual).  The arrows indicate the direction to move to get to the set out point. NextPt To add the next point to be set out. Field Description Horizontal direction from the measured point to the set out point. Positive if the ...
  • Page 57: Cogo

    R6, Applications Next step • Either, press  ALL to measure and record. • Or, press  BACK to return to the REFERENCE ARC screen. • Or, continue selecting ESC to exit the application. COGO 9.5.1 Starting COGO Description COGO is an application used to perform coordinate geometry calculations such as, coordinates  of points, bearings between points and distances between points The COGO calculation methods are: • Inverse and Traverse • Offset • Intersections • Extension Access Select Apps from the MAIN MENU. Select COGO from the APPS menu. Complete application pre‐settings. Refer to "8 Applications ‐ Getting Started". Select from the COGO MAIN MENU: • • Inverse & Traverse Offset •...
  • Page 58: Intersections

    R6, Applications Traverse Use the traverse subapplication to calculate the position of a new point using the bearing and  the distance from a known point. Offset optional. Known P1 Known point α Direction from P1 to P2 d1 Distance between P1 and P2 d2 Positive offset to the right d3 Negative offset to the left Unknown P2 COGO point without offset P3 COGO point with positive offset P4 COGO point with negative offset 9.5.3 Intersections Access Select Intersection from the COGO MAIN MENU. Select the desired COGO method: • • Brg-Brg Dst-Dst • • Brg-Dst Ln-Ln Bearing­Bearing Use the bearing‐bearing subapplication to calculate the intersection point of two lines. A line is  defined by a point and a direction. Known P1 First known point P2 Second known point...
  • Page 59: Offsets

    R6, Applications Known P1 First known point P2 Second known point α Direction from P1 to P3 and P4 Radius, as the distance from P2 to P4 or P3 Unknown P3 First COGO point P4 Second COGO point Distance­Distance Use the distance‐distance subapplication to calculate the intersection point of two circles. The  circles are defined by the known point as the center point and the distance from the known  point to the COGO point as the radius. Known P1 First known point P2 Second known point r1 Radius, as the distance from P1 to P3 or P4 r2 Radius, as the distance from P2 to P3 or P4 Unknown P3 First COGO point P4 Second COGO point By Points Use the line‐line subapplication to calculate the intersection point of two lines. A line is defined  by two points. Known P1 First known point P2 Second known point P3 Third known point P4 Fourth known point Line from P1 to P2...
  • Page 60: Extension

    R6, Applications Distance ­ Offset Use the distance‐offset subapplication to calculate the distance and offset of a known point, with  the basepoint in relation to a line. Known P0 Instrument station P1 Start point P2 End point P3 Offset point Unknown d1 d Line d2 d Offset P4 COGO (base) point Set point by..Use the set point subapplication to calculate the coordinates of a new point in relation to a line  from known longitudinal and offset distances. Known P0 Instrument station P1 Start point P2 End point d1 d Line d2 d Offset Unknown P3 COGO point 9.5.5 Extension Access Select Extension from the COGO MAIN MENU.
  • Page 61: Missing Line Measurement

    R6, Applications Missing Line Measurement Description Missing Line Measurement is an application used to compute slope distance, horizontal  distance, height difference and azimuth of two target points which are either measured,  selected from the memory, or entered using the keypad. Missing Line Measurement methods The user can choose between two different methods: • Polygonal: P1‐P2, P2‐P3, P3‐P4. • Radial: P1‐P2, P1‐P3, P1‐P4. Polygonal method T101 1st target point T202 2nd target point T303 3rd target point SD 1‐2Slope distance from T101‐T202 SD 2‐3Slope distance from T202‐T303 Az 1‐2Azimuth from T101‐T202 SD 1-2 Az 2‐3Azimuth from T202‐T303 SD 2-3 Radial method 1‐4 Target points SD 1-2 SD 1‐2Slope distance from 1‐2 SD 1-3 SD 1‐3Slope distance from 1‐3 SD 1‐4Slope distance from 1‐4 Az 1‐2Azimuth from 1‐2 Az 1‐3Azimuth from 1‐3 Az 1‐4Azimuth from 1‐4 SD 1-4 Center point Access...
  • Page 62: Resection

    R6, Applications MISSING LINE RESULT ­ Polygonal method NewPt 1 To calculate an additional line. Application starts  again at point 1. NewPt 2 To set point 2 as the starting point of a new line. A  new point 2 must be measured. RADIAL To switch to radial method. Field Description Grade [%] between point 1 and point 2. Grade Slope distance between point 1 and point 2. d.S.D Horizontal distance between point 1 and point 2. d.H.D Height difference between point 1 and point 2. d.d.Z Azimuth between point 1 and point 2. Next step Press ESC to exit the application. Resection 9.7.1 Starting Resection Description Resection is an application used to determine the instruments position from measurements to  known points. A minimum of two known points and a maximum of 5, can be used to determine  the position. Access Select Apps from the MAIN MENU. Select Resection from the APPS menu. Complete application pre‐settings. Refer to "8 Applications ‐ Getting Started". Select Accuracy Limit: ...
  • Page 63: Measuring Information

    R6, Applications • Status: On to activate a warning message if the calculated standard deviation  exceeds the limit. • Set the accuracy limits for the Easting, Northing and Height coordinates and the  standard deviation angle. • Press OK to save the limits and return to the Pre-settings screen. Select GO! to begin the application. Enter target data Enter the name of the station and the height of the instrument in the Station data screen and  press OK.  Next step To access the Sight target point screen: • Either, press OK after entering the target data fields in the Target data screen. • Or, press  SKIP to skip entering the target data fields again when measuring the  same point in another face. Sight target point In the Sight target point screen: 2 / I: Indicates that the second point was measured in face I. 2 / I II: Indicates that the second point was measured in faces I and II. CALC.
  • Page 64: Computation Procedure

    R6, Applications Dual face measurements When measuring the same target in both faces, the reflector height may not be changed when  observing in the second face. Error checks are made for dual face measurements to ensure the  same point is sighted with the other face. • If a target point is measured several times in the same face, only the last valid measure‐ ment is used for computation. • For the calculation of the station position, measured target points can be re‐measured,  included in calculations, or excluded from calculations. Measurements not included in computations Target points with 0.000 height are discarded for height processing. If a target point  has a valid  height of 0.000 m, use 0.001 m to include it for height processing. 9.7.3 Computation Procedure Description The measuring procedure automatically determines the method of evaluation, for example  resection or three point resection. If more than the minimum required measurements are performed, the procedure uses a least  squares adjustment to determine the 3D position and averages orientation and height measure‐ ments. • The original averaged face I and face II measurements are used for the computation  process.  • All measurements are treated with the same accuracy, whether these are measured in  single or dual face. • Easting and Northing are determined by the least squares method, which includes  standard deviation and improvements for horizontal direction and horizontal distances. • The final height (H) is computed from averaged height differences based on the original  measurements. • The horizontal direction is computed with the original averaged face I and face II meas‐ urements and the final computed plan position. 9.7.4 Resection Results Access Press CALC. from the Sight target point screen after at least two points and a distance have ...
  • Page 65 R6, Applications Standard deviations and residuals for accuracy assessments are provided. RESID To display residuals. Refer to "Target Residuals". StdDev To display the standard deviation of the coordinates  and angle. If the instrument height was set to 0.000 in the setup screen, then the station height  refers to the height of the tilting axis. Next step Press RESID to display the target residuals. Target Residuals The TARGET RESIDUALS screen displays the computed residuals for the horizontal and  vertical distances and the horizontal direction. Residual = Calculated value ‐ Measured value. Messages The following are important messages or warnings that may appear. Messages Description This message occurs if the selected target point has no Easting or  Selected point has no Northing coordinate. valid data! 5 points have already been measured and another point is  Max 5 points selected. The system supports a maximum of 5 points. supported! The measurements may not allow final station coordinates  Invalid data - no posi- (Eastings, Northings) to be computed. tion computed! Either the target height is invalid or insufficient measurements ...
  • Page 66: Set Out

    R6, Applications Next step Press OK to return to the APPS menu. Set Out Description Set Out is an application used to place marks in the field at predetermined points. These prede‐ termined points are the points to be staked. The points to be staked may  already exist in a job  on the instrument, or be manually entered. The application can continuously display differences, between current position and desired set  out position. Set Out modes Points can be staked using different modes: Polar mode, Orthogonal to station mode and Carte‐ sian mode. Polar Set Out mode Current position Point to be set out dHDLongitudinal offset: positive if point to be setout is  further away. dHAAngle offset: positive if point to be setout is to the  right of the actual direction. Orthogonal to Station Set Out mode Current position Point to be set out dL Longitudinal offset: positive if nominal point is  further away. +d T d HA dT Transversal offset, perpendicular to line‐of‐sight:  +d L positive if nominal point is to the right of the meas‐ ured point. dHAAngle offset: positive if nominal point is to the right  of the actual direction. Cartesian Set Out mode Current position Point to be set out +d N +d E...
  • Page 67 R6, Applications Access Select Apps from the MAIN MENU. Select Set Out from the APPS menu. Complete application pre‐settings. Refer to "8 Applications ‐ Getting Started". SET OUT MANUAL To manually enter coordinates of a point. B&D To enter the direction and horizontal distance to a set  out point. Press   to move through the pages. The bottom three measurement fields on the  screen will change for the Polar, Orthogonal or Cartesian modes. Field Description Value for Point ID search. After entry, the firmware searches for matching points,  Find and displays these in Pt: If a matching point doesn’t exist the pointsearch screen  opens. Angle offset: Positive if set out point is to the right of the measured point. d HA Horizontal offset: Positive if set out point is further away than the measured  d.H.D point. Height offset: Positive if set out point is higher than the measured point. d.d.Z Longitudinal offset: Positive if set out point is further away than the measured  dLength point. Perpendicular offset: Positive if set out point is to the right of the measured point. dTrav. Easting offset: Positive if set out point is to the right of the measured point. Northing offset: Positive if set out point is further away than the measured point Height offset: Positive if set out point is higher than the measured point. Next step • Either, press ALL to record measurements for a set out point.
  • Page 68: Area & Volume

    R6, Applications Area & Volume Description Area is an application used to compute online areas to a maximum of 50 points connected by  straights. The target points have to be measured, selected from memory, or entered via the  keypad in a clockwise direction. The calculated area is projected onto the horizontal plane (2D)  or projected onto the sloped reference plane defined by three points (3D). Furthermore a  volume with constant height can be calculated in relation to the area (2D/3D). P0 Instrument station P1 Start point P2‐4Target points Perimeter, polygonal length from start point to the  current measured point. Calculated area always closed to the start point P1,  projected onto the horizontal plane. Access Select Apps from the MAIN MENU. Select Area & Volume from the APPS menu. Complete application pre‐settings. Refer to "8 Applications ‐ Getting Started". AREA & VOLUME The graphic always shows the area projected onto the horizontal plane. 1PtBACK To undo measurement or selection of the previous  point. CALC To display and record additional results (perimeter,  volume). VOLUME To calculate a volume with constant height. The  heights have to be entered or measured. Def. 3D To define the sloped reference plane by selecting or  measuring three points. The 2D area is calculated and displayed once three points have been measured or selected. The ...
  • Page 69: Remote Elevation

    R6, Applications Graphical representation P0Instrument station P1Target point which defines the sloped reference  plane P2Target point which defines the sloped reference  plane P3Target point which defines the sloped reference  plane P4Target point a Constant height b Perimeter (3D), polygonal length from the start point  to the current measured point of the area (3D) c Area (3D), projected onto the sloped reference plane d Volume (3D) = a x c e Perimeter (2D), polygonal length from the start point  to the current measured point of the area (2D) f Area (2D), projected onto the horizontal plane g Volume (2D) = f x a Next step Press CALC to calculate area and volume and proceed to the Area & Volume Result screens. 2D/3D­AREA & VOLUME RESULT Perimeter and volume are updated if further area points are added. Next step • Either, press New to define a new area. • Or, press AddTg to add a new target point to the existing area. • Or, press ESC to exit the application.
  • Page 70: Construction

    R6, Applications 1 Remote point 2 Height difference 3 Slope distance 4 Base point Access Select Apps from the MAIN MENU. Select Remote Elevation from the APPS menu. Complete application pre‐settings. Refer to "8 Applications ‐ Getting Started". Remote elevation measurement Measure to the base point or press  Tgt.H=? to determine an unknown reflector height. Next step After measuring, the REMOTE ELEVATION screen appears. REMOTE ELEVATION ­ Aim at remote point Aim the instrument at the inaccessible remote point. Field Description Height difference between the base point and the remote point. hDIST Height of the remote point. Calculated difference in Height between the base point and the remote point. d.d.Z Next step • Either, press OK to save the measurement of the remote point. • Or, press BACK to enter and measure a new base point. • Or, press ESC to exit the application. 9.11 Construction 9.11.1 Starting Construction Description...
  • Page 71: Layout

    R6, Applications Access Select Apps from the MAIN MENU. Select Construction from the APPS menu. Select Set EDM: to set the EDM settings. Refer to "4.2 EDM Settings". Select: • New line ‐ To define a new construction site, or • Continue with line ‐ To continue with a previous construction site (skips set‐up). If coordinates were entered by COORD and measured to known points, a plausibility check  displays the calculated line length, the actual length and the difference. Next step Measure to the line start and end points and the LAY-OUT screen appears. 9.11.2 Layout Description Search or enter points for setting out relative to the defined construction line. The on‐screen  graphics show the position of the prism relative to the set out point. Below the graphic, the exact  values are displayed, combined with arrows to show the direction for setting out the point. • Be aware that the line start point and the line end point are measured in the previous coor‐ dinate system. When setting out these points they appear in the old system and appear as  shifted. • During use of the application the previous orientation and station parameters will be  replaced by the new calculated ones. The line start point will be set to E=0, N=0. • The height of the line start point is always used as the reference height! Access • Either, select New line from the Construction pre‐settings screen and measure start and  end points of the line. •...
  • Page 72: As Built Check

    R6, Applications AsBLT To switch to AsBuilt mode to check points relative to  the construction line. Shift To enter values for shifting the line. Field Description Longitudinal offset: Positive if target point is further away than the measured  point. Perpendicular offset: Positive if target point is to the right of the measured point. Height offset: Positive if target point is higher than the measured point. d HG Next step • Either, press AsBLT to check point locations relative to a contruction line. • Or, press  Shift to enter offset values for shifting the construction line. 9.11.3 As Built Check Description The As built screen displays the Line, Offset and d.d.Z of a measured point in relation to the  construction line. The on‐screen graphics show the position of the measured point relative to  the construction line. The height of the line start point is always used as the reference height! Access Press AsBLT from the LAY OUT screen. AS­BUILT CHECK The graphics are scaled to give a better overview. Therefore it is possible that the station point  moves in the graphics. LAYOUT To switch to Layout mode to set out points. Shift To enter values for shifting the line. Field Description Longitudinal offset: Positive if measured point is further along the construction ...
  • Page 73 R6, Applications Field Description Perpendicular offset: Positive if measured point is to the right of the construction  line. Calculated difference in height: Positive if measured point is higher than the  d HGT construction line start point height.
  • Page 74: Data Management

    R6, Data Management 10 Data Management 10.1 Data Management Access Select Data from the MAIN MENU. DATA MANAGEMENT The Data Management menu contains all functions for entering, editing, checking and deleting  data in the field. F1-F4 To select menu item. Menu item Description To view, create and delete jobs. Jobs are a summary of data of different  types, for example, known points, observations or codes. The job defini‐ tion consists of the job name and user. The system generates time and date  at the time of creation. To view, create, edit and delete known points. Valid fixed points contain at  Known points least the point ID and the coordinates E, N or H. To view and delete observation data. Observation data available in the  Observations internal memory can be searched for via a specific point search, or by  viewing all points within a job. To view, create, edit and delete codes. To each code a description and a  Code Library maximum of 8 attributes with up to 16 characters each can be assigned. To view and delete data format files. Formats To delete individual jobs, known points and measurements of a specific  Erase Job job or all jobs in the memory. Memory Deleting the memory cannot be undone. After confirming the  message all data is permanently deleted.
  • Page 75: Exporting Data

    R6, Data Management Menu item Description To view, delete, rename and create folders and files stored on the USB  USB-Explorer memory stick. Only available for Zoom 30 instruments. Refer to "10.4 Working with a USB Memory Stick"and "Appendix B Direc‐ tory Structure". Next step • Either, select a menu option using F1 ‐ F4. • Or, press ESC to return to the MAIN MENU. 10.2 Exporting Data Description Job data can be exported from the internal memory of the instrument. Data can be exported via: The RS232 serial interface A receiver, such as a laptop, is connected to the RS232 port. The receiver requires Zoom or  another third party software. If the receiver is too slow in processing data the data could be lost. With this type  of data transfer the instrument is not informed about the performance of the  receiver (no protocol). Therefore the success of this type of transfer is not checked. A USB memory stick For Zoom 30 instruments. A USB memory stick can be inserted and removed from the USB host  port. No additional software is required for the transfer. Access Select Transfer from the MAIN MENU. Select Export Data. DATA EXPORT SEARCH To search for jobs within the internal memory. DISPL. To list all jobs within the internal memory. Field Description USB memory stick or RS232 serial interface.
  • Page 76: Importing Data

    R6, Data Management Export data step­by­step Press OK in the DATA EXPORT screen after selecting the export details. Select the data format and press OK or SEND. The ASCII data format is only available for data exports to a USB memory stick, not via the  RS232 serial interface. All jobs will be stored in the backup folder created on the USB memory stick. The job data will  be stored as individual database files for each job, which can then be imported again. Refer to  "10.3 Importing Data". Exportable job data formats Job data can be exported from a job in a variety of file types. A format can be defined in GGO  Format Manager. Refer to the online help of GGO for information on creating format files. RS232 example job data output Within the Data Type setting Observations, a data set could be shown as follows: 11..+00000D19 21..022+16641826 22..022+09635023 31..00+00006649 58..16+00000344 81..00+00003342 82..00‐00005736 83..00+00000091 87..10+00001700 GSI­IDs GSI­IDs continued 41‐49 Codes and attributes Horizontal direction ppm [mm] Vertical angle Prism constants Orientation 81‐83 (E, N, H) Target point Slope distance 84‐86 (E, N, H) Station point Horizontal distance Reflector height...
  • Page 77 R6, Data Management Importable data formats When importing data, the instrument automatically stores the file in a directory folder based on  the file extension. The following data formats can be imported: Data Type File extension Recognised as .gsi Known points Format .frt Format file Codelist .cls Codelist file Access Select Transfer from the MAIN MENU. Select Import Data. DATA IMPORT Field Description From USB-Stick Instrument File Single File Import data step­by­step Press OK in the DATA IMPORT screen to proceed to the USB memory stick file directory. Select the file on the USB memory stick to be imported and press OK. Define the Job name for the imported file, and, if requested, the file definition and layers,  and press OK to import. If a Job with the same name already exists in the internal memory,  a message will appear with the options to overwrite the existing job or rename the job for  the file being imported. A message will display once the file has been successfully imported.
  • Page 78: Working With A Usb Memory Stick

    R6, Data Management 10.4 Working with a USB Memory Stick Insert a USB memory stick step­by­step Lift the lid covering the USB host port on the Zoom 30  instrument. Insert the USB memory stick into the USB host port. Zoom_008 Always return to the Main Menu before removing the USB memory stick. ® Stonex  cannot be held responsible for data loss or any other error that may occur when using  a USB memory stick. • Keep the USB memory stick dry. • Use it only within the specified temperature range. • Protect the USB memory stick from direct impacts. Failure to follow these instructions could result in data loss and/or permanent damage to the  USB memory stick. 10.5 Working with Bluetooth Description Zoom 30 instruments can communicate with external devices via a Bluetooth connection. The  instrument Bluetooth is a slave only. The Bluetooth of the external device will be the master,  and therefore will control the connection and any data transfer. Establishing a connection step­by­step On the instrument ensure that the communication parameters are set to Bluetooth and  On. Refer to "4.3 Communication Settings". Activate Bluetooth on the external device. The steps required depend on the Bluetooth  driver and other device specific configurations. Refer to the device user manual for infor‐ mation on how to configure and search for a Bluetooth connection. The instrument will appear on the external device. 3 Some devices ask for the identification number of the Bluetooth. The default number for a  Zoom Bluetooth is 0000. This can be changed by:...
  • Page 79: Working With Geomax Geo Office And Ggo Tools

    R6, Data Management • Select Settings from the MAIN MENU. • Select Comm. from the SETTINGS menu. • Press BTCode from the COMMUNICATION SETTINGS screen. • Enter a new Bluetooth code in BT-Code: • Press OK to confirm the new Bluetooth code. 4 When the external Bluetooth device has located the instrument for the first time, a message  will display on the instrument stating the name of the external device and requesting confir‐ mation that connection to this device should be allowed. • Press YES to allow, or • Press NO to disallow this connection 5 The instrument Bluetooth sends out the instrument name and serial number to the external  Bluetooth device. 6 All further steps must be made in accordance to the user manual of the external device. Transferring data via Bluetooth Using GGO Data Exchange Manager, data files can be transferred from the instrument to a local  folder via the Bluetooth connection. The transfer is made through the serial port configured on  the computer as the Bluetooth Serial Port, however, for faster data transfer speeds we recom‐ mend using the USB or RS232 connections. For more information about GGO Data Exchange Manager refer to the comprehensive online  help. For transferring data using other external devices or software programs, refer to the user  manual of the device or software. The Zoom 30 Bluetooth does not establish or manage the data  transfer. 10.6 Working with GeoMax Geo Office and GGO Tools Description The program package GGO is used for the data exchange between the instrument and a ...
  • Page 80: Calibration

    R6, Calibration 11 Calibration 11.1 Overview Description ® Stonex  instruments are manufactured, assembled and adjusted to a high quality. Quick  temperature changes, shock or stress can cause deviations and decrease the instrument accu‐ racy. It is therefore recommended to calibrate the instrument from time to time. This can be  done in the field by running through specific measurement procedures. The procedures are  guided and have to be followed carefully and precisely as described in the following chapters.  Some other instrument errors and mechanical parts can be adjusted mechanically. Electronic calibration The following instrument errors can be checked and calibrated electronically: • Horizontal collimation error, also called line‐of‐sight error. • Vertical index error, and simultaneously the electronic level. For determining these errors, it is necessary to measure in both faces, but the procedure can be  started in any face. Mechanical calibration The following instrument parts can be calibrated mechanically: • Circular level on the instrument and tribrach. • Laser plummet. • Screws on the tripod. During the manufacturing process, the instrument errors are carefully determined and set to  zero. As mentioned, these errors can change and it is highly recommended to redetermine them  in the following situations: • Before the instrument is used for the first time. • Before every high precision survey. • After rough or long periods of transport. •...
  • Page 81: Calibrating Line-Of-Sight And Vertical Index Error

    R6, Calibration Before determining the instrument errors, level‐up the instrument using the elec‐ tronic level. The Level & Plummet is the first screen to appear after turning on  the instrument. The tribrach, the tripod and the ground should be very stable and secure from  vibrations or other disturbances. The instrument should be protected from direct sunlight in order to avoid thermal  expansion on one side only. Before starting to work, the instrument has to become acclimatised to the ambient temperature.  Approximately two minutes per °C of temperature difference from storage to working environ‐ ment, but at least 15 min, should be taken into account. 11.3 Calibrating Line­of­Sight and Vertical Index Error Line­of­sight error The line‐of‐sight error, or horizontal collimation error is the deviation from the perpendicular  between the tilting axis and the line of sight. The effect of the line‐of‐sight error to the horizontal  direction increases with the vertical angle. a) Tilting axis b) Line perpendicular to tilting axis c) Horizontal collimation, or line‐of‐sight, error d) Line‐of‐sight Zoom_011 Vertical index error The vertical circle should read exactly 90° (100 gon) when the line of sight is horizontal. Any  deviation from this figure is termed vertical index error. This is a constant error that affects all  vertical angle readings. a) Mechanical vertical axis of the instrument, also called standing  axis b) Axis perpendicular to the vertical axis. True 90° c) Vertical angle is reading 90° d) Vertical index error By determining the vertical index error the electronic ...
  • Page 82 R6, Calibration Access Select Tools from the MAIN MENU. Select Calibr. from the TOOLS MENU. • Select: • HA-collimation, or • Vertical Index. The procedures and conditions required to correct line‐of‐sight and vertical index errors are  the same, therefore the procedure will only be described once. Calibration step­by­step Level the instrument with the electronic level. Refer to "3 Operation"‐ "Level up with the  electronic level step‐by‐step". Aim at a point approximately 100 m from the instru‐ ment which is within 5° of the horizontal. ± 5° Zoom_013 3 Press REC to measure to the target point. Change face and aim at the target point again 180° 180° Zoom_014 For checking the horizontal aim, the difference in HA and VA are displayed. 5 Press REC to measure to the target point. The old and new calculated values are displayed. 6 Either: • Press OK to save the new calibration data, or • Press ESC to exit without saving the new calibration data. Messages The following are important messages or warnings that may appear.
  • Page 83: Calibrating The Circular Level Of The Instrument And Tribrach

    R6, Calibration Messages Description Computed values out of tolerance. The previous values are  Results out of toler- retained and measurements should be repeated. Confirmation of  ance. Previous values the message required. retained ! Horizontal angle in face II deviates by more than 5° from the target  HA-angle not suitable point. Aim on the target point with an accuracy of min. 5°. Confir‐ for adjustment ! mation of the message required. Measurement error appears when, for example, there is an  Measurement Error. unstable set up. Repeat the process. Confirmation of the message  Try again. required. Time difference between measurements for results storage  Time limit exceeded ! exceeds 15 minutes. Repeat the process. Confirmation of the  Please repeat adjust- message required.
  • Page 84: Inspecting The Laser Plummet Of The Instrument

    R6, Calibration 4 Repeat step 3 on the instrument and tribrach until both circular levels are centered and no  further adjustments are necessary. After the calibration, no adjustment screw should be loose. 11.5 Inspecting the Laser Plummet of the Instrument The laser plummet is integrated into the vertical axis of the instrument. Under normal condi‐ tions of use, the laser plummet does not need adjusting. If an adjustment is necessary due to  ® external influences, the instrument has to be returned to a Stonex  service department. Inspect the laser plummet step­by­step Set up the instrument on the tripod approximately 1.5 m above the ground and level up. To activate the laser plummet, turn on the instrument, and, if tilt correction is set to 1‐ or  2‐axis, the laser plummet will be activated automatically, and the Level & Plummet  screen appears. Otherwise, press FNC from within any application and select Level & Plummet. Inspection of the laser plummet should be carried out on a bright, smooth and  horizontal surface, such as a sheet of paper. 3 Mark the center of the red laser dot on the ground. 4 Turn the instrument slowly through 360°, carefully observing the movement of the red laser  dot. The maximum diameter of the circular movement described by the center of  the laser dot should not exceed 3 mm at a height of 1.5 m. 5 If the center of the laser dot makes a clearly circular movement, or moves more than 3 mm  away from the point which was first marked, an adjustment may be required. Call your  ® nearest Stonex  service department.
  • Page 85: Servicing The Tripod

    R6, Calibration 11.6 Servicing the Tripod Service the tripod step­by­step The connections between metal and timber components must always be firm  and tight. Tighten the leg cap screws moderately with the allen key supplied. Tighten the articulated joints on the tripod head just enough to keep the tripod legs open  when lifting the tripod off the ground. Tighten the screws of the tripod legs.
  • Page 86: Care And Transport

    R6, Care and Transport 12 Care and Transport 12.1 Transport Transport in the field When transporting the equipment in the field, always make sure that you • either carry the product in its original transport container, • or carry the tripod with its legs splayed across your shoulder, keeping the attached  product upright. Transport in a road vehicle Never carry the product loose in a road vehicle, as it can be affected by shock and vibration.  Always carry the product in its transport container and secure it. Shipping ® When transporting the product by rail, air or sea, always use the complete original Stonex   packaging, transport container and cardboard box, or its equivalent, to protect against shock  and vibration. Shipping, transport of batteries When transporting or shipping batteries, the person in charge of the product must ensure that  the applicable national and international rules and regulations are observed. Before transpor‐ tation or shipping, contact your local passenger or freight transport company. Field adjustment After transport inspect the field adjustment parameters given in this user manual before using  the product. 12.2 Storage Product Respect the temperature limits when storing the equipment, particularly in summer if the  equipment is inside a vehicle. Refer to "14 Technical Data" for information about temperature  limits. Field adjustment After long periods of storage inspect the field adjustment parameters given in this user manual  before using the product.
  • Page 87: Cleaning And Drying

    R6, Care and Transport Li­Ion batteries • Refer to "14 Technical Data" for information about storage temperature range. • At the recommended storage temperature range, batteries containing a 10% to 50%  charge can be stored for up to one year. After this storage period the batteries must be  recharged. • Remove batteries from the product and the charger before storing. • After storage recharge batteries before using. • Protect batteries from damp and wetness. Wet or damp batteries must be dried before  storing or use. • A storage temperature range of ‐20°C to +30°C/‐4°F to 86°F in a dry environment is  recommended to minimise self‐discharging of the battery. 12.3 Cleaning and Drying Objective, eyepiece and reflectors • Blow dust off lenses and prisms. • Never touch the glass with your fingers. • Use only a clean, soft, lint‐free cloth for cleaning. If necessary, moisten the cloth with water  or pure alcohol. Do not use other liquids; these may attack the polymer components. Fogging of prisms Prisms that are cooler than the ambient temperature tend to fog. It is not enough simply to wipe  them. Keep them for some time inside your jacket or in the vehicle to allow them to adjust to the  ambient temperature. Damp products Dry the product, the transport container, the foam inserts and the accessories at a temperature  not greater than 40°C /104°F and clean them. Do not repack until everything is completely dry.  Always close the transport container when using in the field. Cables and plugs Keep plugs clean and dry. Blow away any dirt lodged in the plugs of the connecting cables. ...
  • Page 88: Safety Directions

    Recording measurements. • Visualizing the aiming direction and vertical axis. • Data communication with external appliances. • Computing by means of software. Adverse use • Use of the product without instruction. • Use outside of the intended limits. • Disabling safety systems. • Removal of hazard notices. • Opening the product using tools, for example screwdriver, unless this is specifically  permitted for certain functions. • Modification or conversion of the product. • Use after misappropriation. • Use of products with obviously recognisable damages or defects. • Use with accessories from other manufacturers without the prior explicit approval of  ® Stonex • Aiming directly into the sun. • Inadequate safeguards at the working site, for example when measuring on roads. • Deliberate dazzling of third parties. • Controlling of machines, moving objects or similar monitoring application without addi‐ tional control‐ and safety installations. Warning Adverse use can lead to injury, malfunction and damage. ...
  • Page 89: Limits Of Use

    R6, Safety Directions It is the task of the person responsible for the equipment to inform the user about hazards and  how to counteract them. The product is not to be operated until the user has been instructed on  how to work with it. 13.3 Limits of Use Environment Suitable for use in an atmosphere appropriate for permanent human habitation: not suitable for  use in aggressive or explosive environments. Danger Local safety authorities and safety experts must be contacted before working in hazardous  areas, or close to electrical installations or similar situations by the person in charge of the  product. 13.4 Responsibilities Manufacturer of the product ® ® Stonex  Europe srl, IT‐20052 Monza, hereinafter referred to as Stonex , is responsible for  supplying the product, including the user manual and original accessories, in a safe condition. ® Manufacturers of non Stonex  accessories ® The manufacturers of non Stonex  accessories for the product are responsible for developing,  implementing and communicating safety concepts for their products, and are also responsible  ® for the effectiveness of those safety concepts in combination with the Stonex  product. Person in charge of the product The person in charge of the product has the following duties: • To understand the safety instructions on the product and the instructions in the user  manual. • To be familiar with local regulations relating to safety and accident prevention.
  • Page 90: Hazards Of Use

    R6, Safety Directions 13.5 Hazards of Use Warning The absence of instruction, or the inadequate imparting of instruction, can lead to incorrect or  adverse use, and can cause accidents with far‐reaching human, material, financial and environ‐ mental consequences. Precautions: All users must follow the safety directions given by the manufacturer and the directions of the  person responsible for the product. Caution Watch out for erroneous measurement results if the product has been dropped or has been  misused, modified, stored for long periods or transported. Precautions: Periodically carry out test measurements and perform the field adjustments indicated in the  user manual, particularly after the product has been subjected to abnormal use and before and  after important measurements. Danger Because of the risk of electrocution, it is dangerous to use poles and extensions in the vicinity of  electrical installations such as power cables or electrical railways. Precautions: Keep at a safe distance from electrical installations. If it is essential to work in this environment,  first contact the safety authorities responsible for the electrical installations and follow their  instructions. Caution Be careful when pointing the product towards the sun, because the telescope functions as a  magnifying glass and can injure your eyes and/or cause damage inside the product. Precautions: Do not point the product directly at the sun. Warning During dynamic applications, for example stakeout procedures there is a danger of accidents  occurring if the user does not pay attention to the environmental conditions around, for  example obstacles, excavations or traffic. Precautions: The person responsible for the product must make all users fully aware of the existing dangers.
  • Page 91 R6, Safety Directions Warning Inadequate securing of the working site can lead to dangerous situations, for example in traffic,  on building sites, and at industrial installations. Precautions: Always ensure that the working site is adequately secured. Adhere to the regulations governing  safety and accident prevention and road traffic. Warning If computers intended for use indoors are used in the field there is a danger of electric shock. Precautions: Adhere to the instructions given by the computer manufacturer regarding field use with  ® Stonex  products. Caution If the accessories used with the product are not properly secured and the product is subjected  to mechanical shock, for example blows or falling, the product may be damaged or people can  sustain injury. Precautions: When setting‐up the product, make sure that the accessories are correctly adapted, fitted,  secured, and locked in position. Avoid subjecting the product to mechanical stress. Warning If the product is used with accessories, for example masts, staffs, poles, you may increase the  risk of being struck by lightning. Precautions: Do not use the product in a thunderstorm. Warning ® If charged or discharged, batteries not recommended by Stonex  may be damaged. They may  burn and explode. Precautions: ® Only charge and discharge batteries recommended by Stonex Warning ® Using a battery charger not recommended by Stonex  can destroy the batteries. This can cause ...
  • Page 92 During the transport, shipping or disposal of batteries it is possible for inappropriate mechan‐ ical influences to constitute a fire hazard. Precautions: Before shipping the product or disposing of it, discharge the batteries by running the product  until they are flat. When transporting or shipping batteries, the person in charge of the product must ensure that  the applicable national and international rules and regulations are observed. Before transpor‐ tation or shipping contact your local passenger or freight transport company. Warning High mechanical stress, high ambient temperatures or immersion into fluids can cause leakage,  fire or explosions of the batteries. Precautions: Protect the batteries from mechanical influences and high ambient temperatures. Do not drop  or immerse batteries into fluids. Warning If battery terminals come in contact with jewellery, keys, metallised paper or other metals,  short circuited battery terminals can overheat and cause injury or fire, for example by storing  or transporting in pockets. Precautions: Make sure that the battery terminals do not come into contact with metallic objects. Warning If the product is improperly disposed of, the following can happen: • If polymer parts are burnt, poisonous gases are produced which may impair health. • If batteries are damaged or are heated strongly, they can explode and cause poisoning,  burning, corrosion or environmental contamination. • By disposing of the product irresponsibly you may enable unauthorised persons to use it  in contravention of the regulations, exposing themselves and third parties to the risk of  severe injury and rendering the environment liable to contamination. Precautions: The product must not be disposed with household waste. Dispose of the product appropriately in accordance with the national regula‐ tions in force in your country. Always prevent access to the product by unauthorised personnel. Warning ® Only Stonex  authorised service workshops are entitled to repair these products.
  • Page 93: Laser Classification

    R6, Safety Directions 13.6 Laser Classification 13.6.1 General General The following directions (in accordance with the state of the art ‐ international standard IEC  60825‐1 (2007‐03) and IEC TR 60825‐14 (2004‐02)) provide instruction and training informa‐ tion to the person responsible for the product and the person who actually uses the equipment,  to anticipate and avoid operational hazards. The person responsible for the product must ensure that all users understand these directions  and adhere to them. Products classified as laser class 1, class 2 and class 3R do not require: • laser safety officer involvement, • protective clothes and eyewear, • special warning signs in the laser working area if used and operated as defined in this user manual due to the low eye hazard  level. Products classified as laser class 2 or class 3R may cause dazzle, flash‐blindness  and afterimages, particularly under low ambient light conditions. 13.6.2 Distancer, Measurements with Reflectors General The EDM module built into this product produces a visible laser beam which emerges from the  telescope objective. The laser product described in this section, is classified as laser class 1 in accordance with: • IEC 60825‐1 (2007‐03): "Safety of laser products". • EN 60825‐1 (2007‐10): "Safety of laser products". Class 1 laser products are safe under reasonably foreseeable conditions of operation and are  not harmful to the eyes provided that the products are used and maintained in accordance with  this user manual. Description Value Maximum average radiant power 0.33 mW Pulse duration 800 ps...
  • Page 94: Distancer, Measurements Without Reflectors

    R6, Safety Directions Labelling ......... . . Class 1 Laser Product .
  • Page 95 R6, Safety Directions Warning From a safety perspective class 3R laser products should be treated as potentially hazardous. Precautions: Prevent direct eye exposure to the beam. Do not direct the beam at other people. Warning Potential hazards are not only related to direct beams but also to reflected beams aimed at  reflecting surfaces such as prisms, windows, mirrors, metallic surfaces etc. Precautions: Do not aim at areas that are essentially reflective, such as a mirror, or which could emit  unwanted reflections. Do not look through or beside the optical sight at prisms or reflecting objects when the laser is  switched on, in laser pointer or distance measurement mode. Aiming at prisms is only  permitted when looking through the telescope. Labelling Laser Aperture Laser Radiation Avoid direct eye exposure Class 3R Laser Product according to IEC 60825-1 (2007 - 03) Po 5.00 mW λ = 650 - 690 nm Zoom_020 a) Laser beam...
  • Page 96: Laser Plummet

    R6, Safety Directions ..........
  • Page 97: Electromagnetic Compatibility Emc

    R6, Safety Directions Labelling ..........
  • Page 98 R6, Safety Directions Although the product meets the strict regulations and standards which are in force in this  respect, GeoMax cannot completely exclude the possibility that other equipment may be  disturbed. Caution There is a risk that disturbances may be caused in other equipment if the product is used with  accessories from other manufacturers, for example field computers, personal computers, two‐ way radios, non‐standard cables or external batteries. Precautions: Use only the equipment and accessories recommended by GeoMax. When combined with the  product, they meet the strict requirements stipulated by the guidelines and standards. When  using computers and two‐way radios, pay attention to the information about electromagnetic  compatibility provided by the manufacturer. Caution Disturbances caused by electromagnetic radiation can result in erroneous measurements. Although the product meets the strict regulations and standards which are in force in this  respect, GeoMax cannot completely exclude the possibility that the product may be disturbed  by intense electromagnetic radiation, for example, near radio transmitters, two‐way radios or  diesel generators. Precautions: Check the plausibility of results obtained under these conditions. Warning If the product is operated with connecting cables attached at only one of their two ends, for  example external supply cables, interface cables, the permitted level of electromagnetic radia‐ tion may be exceeded and the correct functioning of other products may be impaired.  Precautions: While the product is in use, connecting cables, for example product to external battery, product  to computer, must be connected at both ends. Bluetooth Use of product with Bluetooth: Warning Electromagnetic radiation can cause disturbances in other equipment, in installations, in  medical devices, for example pacemakers or hearing aids and in aircraft. It can also affect  humans and animals.  Precautions: Although the product meets in combination with radio or digital cellular phone devices recom‐ mended by GeoMax the strict regulations and standards which are in force in this respect, ...
  • Page 99: Fcc Statement, Applicable In U

    R6, Safety Directions GeoMax cannot completely exclude the possibility that other equipment may be disturbed or  that humans or animals may be affected. • Do not operate the product with radio or digital cellular phone devices in the vicinity of  filling stations or chemical installations, or in other areas where an explosion hazard  exists. • Do not operate the product with radio or digital cellular phone devices near to medical  equipment. • Do not operate the product with radio or digital cellular phone devices in aircraft. 13.8 FCC Statement, Applicable in U.S. Applicability The greyed paragraph below is only applicable for Zoom 20 instruments. Warning This equipment has been tested and found to comply with the limits for a Class B digital device,  pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a  residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and  used in accordance with the instructions, may cause harmful interference to radio communica‐ tions. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be  determined by turning the equipment off and on, the user is encouraged to try to correct the  interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and the receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver  is connected. • Consult the dealer or an experienced radio/TV technician for help. Warning Changes or modifications not expressly approved by GeoMax for compliance could void the  user's authority to operate the equipment.
  • Page 100 R6, Safety Directions Labelling Zoom instrument ..........
  • Page 101: Technical Data

    R6, Technical Data 14 Technical Data 14.1 Angle Measurement Accuracy Available  Standard deviation  Display resolution angular accu­ HA, VA, ISO 17123­3 racies ["] [mgon] ["] [°] [mgon] [mil] 0.0001 0.01 0.0001 0.01 0.0001 0.01 0.0001 0.01 Characteristics Absolute, continuous, diametric. Updates each 0.1 to 0.3 s. 14.2 Distance Measurement with Reflectors Range Reflector Range A Range B Range C [ft] [ft] [ft] Standard prism 1800...
  • Page 102: Distancer, Measurements Without Reflectors (Reflectorless Mode)

    R6, Technical Data EDM measuring mode Standard deviation ISO 17123­4 Measurement time, typical [s] IR‐Default 2 mm + 2 ppm IR‐Quick 5 mm + 2 ppm IR‐Continuous 5 mm + 2 ppm <0.15 Foil 5 mm + 2 ppm Beam interruptions, severe heat shimmer and moving objects within the beam path can result  in deviations of the specified accuracy. Characteristics Principle: Phase measurement Type: Coaxial, visible red laser Carrier wave: 658 nm Measuring system: System analyser basis 100 MHz ‐ 150 MHz 14.3 Distancer, Measurements without Reflectors (Reflectorless mode) Range A2 (without reflector) Kodak Gray Card Range D...
  • Page 103 R6, Technical Data Display unambiguous: up to 1200 m Atmospheric conditions Range D: Object in strong sunlight, severe heat shimmer Range E: Object in share, or overcast Range F: Day, night and twilight Accuracy Standard ISO 17123­4 Measure time,  Measure time,  measuring typical [s] maximum [s] 0 m ‐ 500 m 3 mm + 2 ppm 3 ‐ 6 >500 m 4 mm + 2 ppm 3 ‐ 6 Beam interruptions, severe heat shimmer and moving objects within the beam path can result  in deviations of the specified accuracy. Continuous measuring* Standard deviation Measure time, typical [s] Continuous 5 mm + 3 ppm 0.25 * Accuracy and measure time depend on atmospheric conditions, target object and observa‐...
  • Page 104: Distance Measurement Reflector (Long Range)

    R6, Technical Data 14.4 Distance Measurement Reflector (Long Range) Range A2, A4, A6, (with reflector) Range A Range B Range C [ft] [ft] [ft] Standard prism 2200 7300 7500 24600 >10000 >33000 Reflector foil 2000 1000 3300 1300 4200 60 mm x 60 mm Range of measurement: From 1000 m up to 12000 m Display unambiguous: Up to 12 km Atmospheric conditions Range A: Strong haze, visibility 5 km; or strong sunlight, severe heat shimmer Range B: Light haze, visibility about 20 km; or moderate sunlight, slight heat shimmer Range C: Overcast, no haze, visibility about 40 km; no heat shimmer...
  • Page 105: General Technical Data Of The Instrument

    R6, Technical Data 14.5.2 Zoom 30 Conformity to national regulations • FCC Part 15 (applicable in US). • Hereby, GeoMax AG, declares that the Zoom 30 instrument is in compliance with the  essential requirements and other relevant provisions of Directive 1999/5/EC. The decla‐ ration of conformity is available from GeoMax AG. Class 1 equipment according European Directive 1999/5/EC (R&TTE) can be  placed on the market and be put into service without restrictions in any EEA  Member state. • The conformity for countries with other national regulations not covered by the FCC part  15 or European directive 1999/5/EC has to be approved prior to use and operation. Frequency band 2402 ‐ 2480 MHz Output power Bluetooth: 2.5 mW 14.6 General Technical Data of the Instrument Telescope Magnification: 30 x Free Objective aperture: 40 mm Focusing: 1.7 m/5.6 ft to infinity Field of view: 1°30’/1.66 gon. 2.7 m at 100 m Compensation Quadruple axis compensation (2‐axis compensator with HA‐collimation and VA‐Index).
  • Page 106 R6, Technical Data Level Circular level sensitivity: 6’/2 mm Electronic level resolution: 2" Control unit Display: 280 x 160 pixels, LCD, backlit, 8 lines with 31 characters each, heatable  (temp. <‐5°). Instrument Ports Name Description RS232 6 pin Hiroshi for power, communication, data transfer. This port is located at the base of the instrument. USB host port* USB memory stick port for data transfer. Bluetooth* Bluetooth connections for communication and data transfer. * Only for Zoom 30 instruments. Instrument Dimensions 226 mm 86.6 mm 86.6 mm 173.2 mm Zoom_024 Zoom_023 Weight Instrument: 4.2 kg ‐ 4.5 kg (depending on hardware configuration) Tribrach: 760 g Battery ZBA400:...
  • Page 107 R6, Technical Data Tilting axis height Without tribrach: 196 mm With tribrach: 240 mm ±5 mm Recording Model Memory Type Number of measurements Zoom 20 / Zoom 30 Internal memory 10,000 Laser plummet Type: Visible red laser class 2 Location: In standing axis of instrument Accuracy: Deviation from plumb line: 1.5 mm (2 sigma) at 1.5 m instrument height Diameter of laser point: 2.5 mm at 1.5 m instrument height Power External supply voltage: Nominal voltage 12.8 V DC, Range 11.5 V‐14 V (via serial interface) Battery ZBA400 Type: Li‐Ion Voltage:...
  • Page 108: Scale Correction

    R6, Technical Data Protection against water, dust and sand Type Protection Zoom instrument IP54 (IEC 60529) Humidity Type Protection Zoom instrument Max 95% non condensing. The effects of condensation are to be effectively counteracted by peri‐ odically drying out the instrument. Automatic corrections The following automatic corrections are made: • Line of sight error • Vertical index error • Tilting axis error • Refraction • Earth curvature • Compensator index error • Standing axis tilt • Circle eccentricity 14.7 Scale Correction Use of scale correction By entering a scale correction, reductions proportional to distance can be taken into account. • Atmospheric correction. • Reduction to mean sea level. •...
  • Page 109 R6, Technical Data Atmospheric corrections °C Atmospheric corrections in ppm with temperature [°C], air pressure [mb] and height [m] at  60 % relative humidity. 550 mb 10001050 mb 50°C 50°C 40°C 40°C 30°C 30°C 20°C 20°C 10°C 10°C 0°C 0°C -10°C -10°C -20°C -20°C 550 mb 950 10001050 mb 5000 m4500 40003500 3000 2500 2000 1500 1000 Atmospheric correction °F Atmospheric corrections in ppm with temperature [°F], air pressure [inch Hg] and height [ft] at ...
  • Page 110: Reduction Formulas

    R6, Technical Data 14.8 Reduction Formulas Formulas Mean Sea Level Instrument  Reflector SD Slope distance HD Horizontal distance VD Height difference The instrument calculates the slope distance, horizontal distance, and height difference in  accordance with the following formulas. Earth curvature (1/R) and mean refraction coefficient  (k = 0.13) are automatically taken into account when calculating the horizontal distance and  height difference. The calculated horizontal distance relates to the station height and not to the  reflector height. Slope distance SD Displayed slope distance [m] SD = D · ( 1 + ppm · 10 ) + mm D0 Uncorrected distance [m] ppmAtmospheric scale correction [mm/km] mmprism constant [mm] Horizontal distance HD Horizontal distance [m] HD = Y - A ·...
  • Page 111: Standard Limited Warranty

    R6, Standard Limited Warranty 15 Standard Limited Warranty ® Two (2) years on Stonex  products The terms and conditions of this Limited Warranty constitute the complete and exclusive  ® warranty agreement between the customer and Stonex  for the product and supersede any  ® prior agreement or representation made in any Stonex  sales document or advice that may be  ® provided to customer by any Stonex  representative in connection with customer’s purchase  of the product. No change to the conditions of this Limited Warranty is valid unless it is made in  ® written form and signed by an authorised Stonex  supervisor. ® Stonex  Europe warrants that its products: are free from defects in materials or workmanship; are in conformity with the factory specifications in effect at the time they were manufac‐ tured; have been tested/calibrated in proper working status prior to shipment. ® At its sole discretion, Stonex  Europe will restore the product to original working order (in  accordance with factory specifications in effect at the time the product was manufactured) OR  replace the product with one at least equivalent to the original product. Replaced parts or prod‐ ucts are warranted to be free from defects in materials and workmanship for thirty (30) days  OR for the remainder of the Limited Warranty Period of the product in which they are installed,  whichever is longer. Parts or products replaced under this Limited Warranty shall become  ® property of Stonex  Europe. All parts that have to be replaced have to be returned to our repre‐...
  • Page 112 R6, Standard Limited Warranty Return policy ® All returned products have to be shipped to Stonex  Europe representative office. The original  Purchaser has a period of seven (7) days or otherwise specified to return any purchase for a full  refund (less shipping and handling), provided the merchandise is in new,resalable condition  and returned in the original, undamaged packaging. Customer has to pay for both the return and the original freight fees, regardless of the original freight paid by the  Company. All warranty books, instruction manuals, parts and accessories must be included as  well the original box in which the item was shipped. We recommend to place the original carton  inside another box, to avoid any additional damage to the carton itself. In some cases, returns of  special items will require a re‐stock fee, as imposed by the manufacturer. Used items may not  be returned, if in anyway damaged. Acceptance of returned merchandise is final only after  ® inspection by Stonex  Europe. Once approved, allow fourteen (14) business days after return  for refund to be issued or credited to the account. Disclaimer and Limitation of Remedy ALL OTHER EXPRESS AND IMPLIED WARRANTIES FOR THIS PRODUCT, INCLUDING THE  IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE  AND/OR NONINFRINGEMENT OF ANY THIRD PARTY’S RIGHTS, ARE HEREBY DISCLAIMED.  ® STONEX  EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED  WARRANTY. ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED IN  DURATION TO THE TERM OF THIS LIMITED WARRANTY. SOME JURISDICTIONS DO NOT  ALLOW THE EXCLUSION OF IMPLIED WARRANTIES OR LIMITATIONS ON HOW LONG AN  IMPLIED WARRANTY LASTS, SO THE ABOVE EXCLUSIONS OR LIMITATIONS MAY NOT APPLY  TO CUSTOMER. CUSTOMER MUST READ AND FOLLOW ALL SET‐UP AND USAGE INSTRUC‐ TIONS IN THE APPLICABLE USER GUIDES AND/OR MANUALS ENCLOSED. IF CUSTOMER FAILS  TO DO SO, THIS PRODUCT MAY NOT FUNCTION PROPERLY AND MAY BE DAMAGED.  ® CUSTOMER MAY LOSE DATA OR SUSTAIN PERSONAL INJURIES. STONEX , ITS AFFILIATES  AND SUPPLIERS DO NOT WARRANT THAT OPERATION OF THIS PRODUCT WILL BE UNINTER‐...
  • Page 113 R6, Standard Limited Warranty CUSTOMER SPECIFIC LEGAL RIGHTS, AND CUSTOMER MAY ALSO HAVE OTHER RIGHTS  WHICH VARY FROM COUNTRY/STATE/JURISDICTION TO COUNTRY/STATE/JURISDICTION. Environmental recycling The cardboard box, the plastic in the package and the various parts of this product have to be  recycled and disposed of in accordance with the current legislation of your Country. FOR COUNTRIES IN THE EUROPEAN UNION (EU) The disposal of electric and electronic device as solid urban waste is strictly prohibited:  they must be collected separately. Contact Local Authorities to obtain practical information about correct handling of the  waste, location and times of waste collection centres. When you buy a new device of ours,  you can give back to our dealer a used similar device. The dumping of these devices at unequipped or unauthorised places may have hazardous  effects on health and environment. The crossed dustbin symbol means that the device must be taken to authorised collection  centres and must be handled separately from solid urban waste. FOR COUNTRIES OUTSIDE EUROPEAN UNION (EU) The treatment, recycling, collection and disposal of electric and electronic devices may vary in  accordance with the laws in force in the Country in question.
  • Page 114: Glossary

    R6, Glossary 16 Glossary Instrument axis ZA= Line of sight / collimation axis Telescope axis = line from the cross hairs to the center of the  objective. SA= Standing axis Vertical rotation axis of the telescope. KA= Tilting axis Horizontal rotation axis of the telescope. Also known as the  Trunion axis. V = Vertical angle / zenith angle VK= Vertical circle With coded circular division for reading the vertical angle. Hz= Horizontal direction HK= Horizontal circle With coded circular division for reading the horizontal angle. TSOX_002 Plumb line / compensator Direction of gravity. The compensator defines the plumb line ...
  • Page 115 R6, Glossary Crosshairs Glass plate within the telescope with reticle. Line­of­sight error (horizontal collimation) The line‐of‐sight error (c) is the deviation from the perpendicular  between the tilting axis and line of sight. This could be eliminated  by measuring in both faces. TS0X_005 Vertical index error With a horizontal line of sight the vertical circle reading should be  exactly 90°(100 gon). The deviation from this value is termed the  Vertical index error (i). TS0X_006 Explanation of displayed data SD Indicated meteorological corrected slope distance between  E, N, Z instrument tilting axis and center of prism/laser dot HD Indicated meteorological corrected horizontal distance VD Height difference between station and target point hr Reflector height above ground hi Instrument height above ground Stn.E, Stn.N, Stn.Z Easting, Northing and Height coordinates of station E, N, Z Stn.E, Stn.N, Stn.Z Easting, Northing and Height coordinates of target point...
  • Page 116: Appendix Amenu Tree

    R6, Menu Tree Appendix AMenu Tree Depending on local firmware versions the menu items may differ. Menu Tree |—— Apps |—— Survey |—— Reference Element |—— COGO |—— Missing Line Measurement |—— Resection |—— Setout |—— Area & Volume |—— Remote Elevation |—— Construction |—— Data |—— Jobs |—— Known Points |—— Observations |—— Code Library |—— Formats |—— Erase Job Memory |—— Memory Info |—— USB‐Explorer |—— Settings |—— General |—— Contrast, Tilt Correction, HA Correction, Face I Definition, HA  Increment, VA‐Setting, Angle Unit, Minimum Reading,  Distance Unit, Temperature Unit, Pressure Unit, Beep, Sector  Beep, Screen IIIumination, Crosshair IIIumination, Heating,  Data Output, GSI Format, Mask, Code Saving, Language, Auto‐ Off. |—— EDM |—— EDM Setting, Atmospheric Data, Free Entry PPM, Projection  Scale, EDM Signal Reflection, EDM Frequency |—— Comm. |—— Communication Settings, Bluetooth Code |—— Survey |—— Transfer |—— Export Data...
  • Page 117 R6, Menu Tree...
  • Page 118: Appendix Bdirectory Structure

    R6, Directory Structure Appendix BDirectory Structure Description On the USB memory stick, files are stored in certain directories. The following diagram is the  default directory structure. Directory Structure |—— CODES • Codelists (*.cls) |—— FORMATS • Format files (*.frt) |—— JOBS • GSI, DXF, ASCII files (*.*) • Logfiles created from applications |—— SYSTEM • Firmware files • Language files • Configuration files (*.cfg)
  • Page 119: Index

    R6, Index Index Bluetooth Code 27 2 Dist. Offset 34 Communication setup 27 Connection 78 Accuracy Data transfer 79 Angle measurement 101 Icon 10 IR mode 101 Output power 105 Reflectorless mode 103 Safety directions 98 RL mode 104 Angle measurement 101 Calibration 80 Angle unit, setting of 22, 32 Combined calibration 81 Application Electronic 80, 82 Survey 46 Errors, view current 29 Applications Inspecting laser plummet 84 Area & Volume 68 Line of sight 81 COGO 57 Mechanical 80 Construction 70 Of circular level on instrument 83 Reference Element 47, 52 Of circular level on tribrach 83 Remote Elevation 69 Preparation 80 Resection 62 Vertical index 81 Set Out 66 Care 86 Applications ‐ Getting Started 40 Circular level, calibration of 83 Pre‐settings for applications 40...
  • Page 120 R6, Index Coordinates, orientation with 44 Corrections Face, setting of 21 Atmospheric 108 FCC Statement 99 Automatic 108 Fields, common 46 Scale 108 File extensions 77 Crosshair illumination, setting of 23 Firmware information 30 Crosshairs 115 Folder structure 118 Formats, management of 74 Formatting Data Internal memory 30 Storage 17 Free PPM, setting of 27 Transfer 75 Functions FNC Data formats 77 Access 32 Data management 74, 74 Description of 32 Data output, setting location of 24 FNC key 9 Data types 77 Databits 28 Date 30 GGO/GGO Tools Delete last observation 32 Description 6 Dimensions, of instrument 106 Glossary 114 Directory structure 118 Display heater, setting of 24 Coding 38 Display, technical details of 106 Ouput mask, setting of 24 Distance Offset 33 Output format, setting of 24...
  • Page 121 R6, Index Operation, of instrument 14 Orientation Job, management of 74 Manual angle setting 43 With Coordinates 43 Keyboard 9 Keys 9 Parity 28 Known point data 74 Plumb line 114 Point search 12 Labelling 94, 95, 97, 100, 100 Pole Length 35 Language Ports Deleting 21 Communication setup 27 Upload language 31 Instrument ports 106 Language, setting of 24 PPM, setting of 27 Laser Pressure unit, setting of 23 Classification 93 Prism Distancer 19 GeoMax constant 26 Laser plummet Type 26 Adjust intensity 16 Prism measurements 20 Inspect 84 Projection scale, setting of 26 Safety directions 96 Technical data 107 Quadruple‐axis compensation 105 Laserbeam On/Off 32 Setting of 26 Recording code, setting of 24 Level 106 Reduction Formulas 110...
  • Page 122 R6, Index Settings, setting of 21 Setup Vertical angle Instrument 14 Description 114 Tripod 14 Setting of 22 Softkeys 11 Vertical index Software Calibration 81 Loading 31 Description 115 Software information Application information 31 Weight 106 Software Licence Agreement 111 Wildcard search 13 Standing axis 114 Stopbits 28 Storage 86 Z‐Coordinate 32, 34 Storage temperature 107 Zenith 22, 114 Survey application 18, 46 Zenith angle 114 Zoom 30 frequency band 105 Technical data 101 Telescope 105 Temperature Battery 107 Instrument 107 USB stick 107 Temperature unit, setting of 23 Terminology 114 Tilt and horizontal corrections 25 Tilt correction, setting of 21 Time 30 Tools Auto start 29 Calibration 29 Load Software 31...
  • Page 123 R6, Index...
  • Page 124 Stonex® Europe srl Via Giulini 1 20052 Monza (MB) Italy Phone +39 03 989 43897 Fax +39 03 989 42483 www.stonexeurope.com...

Table of Contents