Newmans Newburn Installation And Operation Manual

Woodfired central hearing furnace

Advertisement

WOODFIRED CENTRAL HEATING FURNACE
INSTALLATION
and
OPERATION
MANUAL
METALFAB
125 WILSON ST BURNIE TASMANIA
Telephone - 03 6431 4766
Facsimile - 03 6431 6811
Email – sales@newmansplumbing.com.au

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Newburn and is the answer not in the manual?

Questions and answers

Summary of Contents for Newmans Newburn

  • Page 1 WOODFIRED CENTRAL HEATING FURNACE INSTALLATION OPERATION MANUAL METALFAB 125 WILSON ST BURNIE TASMANIA Telephone - 03 6431 4766 Facsimile - 03 6431 6811 Email – sales@newmansplumbing.com.au...
  • Page 2: Installation

    A notice of intention to install may be requested by the local Municipal Authority. The Newburn is suitable for burning dry wood only and is not designed to burn briquettes or coal. Severe damage will result if fossil fuels or accelerants are used.
  • Page 3: Thermostat Location

    350 mm diameter. It is essential that at least five 300 x 100 floor outlets be left open at all times otherwise the Newburn will overheat which will cause damage to the heat exchanger.
  • Page 4: Maintenance

    MAINTENANCE The important thing to remember about your NEWBURN is that it is a woodheater. As such it has the same potential problems and maintenance requirements as any woodheater.  Check regularly that the combustion damper is working correctly and is unobstructed.
  • Page 6: Lighting The Fire

    COMBUSTION AIR DAMPER OPERATION The Combustion Air damper is the heart of the NEWBURN as it controls the amount of air for combustion and therefore fire size. The damper is controlled by the room thermostat to open when the room temperature falls below what the thermostat has been set and to close when the desired temperature is reached.
  • Page 7: Overnight Burning

    SUPPLY AIR FAN OPERATION The Supply Air Fan is automatically controlled by an inbuilt furnace thermostat to operate only when the fire box temperature is sufficient. It may therefore cycle on and off, particularly during slow combustion periods, in response to the firebox temperature.
  • Page 8: Do's And Don'ts

    DO’S AND DON’T’S Do not burn green firewood Do not overload the firebox Do not use the heater to burn rubbish Do not leave the heater unattended with the firebox door open Do not allow ash to build up so that the red hot coals are burning against the steel sides of the heat exchange.
  • Page 9 CLEANING OUT YOUR NEWBURN THIS JOB IS BEST DONE AFTER AN OVERNIGHT BURN. 1. Allow the fire to burn down so there is not much unburned wood left and turn down the room thermostat. 2. Open the firebox door and using a metal fire shovel push the hot coals to one side of the firebox through opening and scrape the remaining ash out into a metal container, leaving unburned wood and hot coals to one side.
  • Page 13: Conditions Of Guarantee

    Heater. The guarantee will not be recognised unless the form below is filled in and returned to the manufacturer. WARRANTY REGISTRATION NEWBURN WOOD FIRED CENTRAL FURNACE Serial No. Date of Purchase...