UNILUX-3 40 / 52 / 55 / 65 TABLE OF CONTENTS Page Introduction 1.1 Preface................1.2 Safety................Location.................. Installation instructions............Operation of the fi replace insert..........Stoking up for the fi rst time............. 6.1 Ventilation............... 6.2 Getting the fi re going............
Page 6
UNILUX-3 40 / 52 / 55 / 65 Directions for use and Installation Instructions...
INTRODUCTION PREFACE We would like to congratulate you on your purchase of this modern BARBAS fi replace insert. This quality product will give you years of heating pleasure as you enjoy the play of the fl ames and the cosy glow of the fi re.
UNILUX-3 40 / 52 / 55 / 65 SAFETY AND INSTALLATION INSTRUCTIONS Safety • Do not place fl ammable objects within 100 cm of the appliance. Pay special attention to furnishings and ornaments around the fi re. • When you use your fi replace insert, the exterior will become hot. Always wear the glove or use the accessories supplied when fi...
Page 9
UNILUX-3 40 / 52 / 55 / 65 Installation instructions • Wood and wood briquettes may be stoked in the stove. Coals can’t be burned in the fi re. • Never use the heater to burn rubbish. • Please read all instructions / stickers on and around the appliance.
UNILUX-3 40 / 52 / 55 / 65 LOCATION INCLUDED Documentation Warranty Manual Attributes Glove (Heat resistant up to max. 95°C) Operating hook / Poker N.B. If any part is missing, please contact your dealer. PREPARATION FOR POSITIONING Check all functions of the fi replace before fi tting.
Page 11
UNILUX-3 40 / 52 / 55 / 65 Handle ± 50° forwards: The door releases from its lock and be opened forwards. • Check the operation and setting of the fl ue gas fl ap. Flue gas fl ap pin Flue gas fl...
Page 12
UNILUX-3 40 / 52 / 55 / 65 • Check the operation of the slider for controlling the combustion air. • Check whether the ashtray is completely empty. Directions for use and Installation Instructions...
Page 13
• 2x collar adaptor Ø125 mm 304040 • 4x Hose clamp Ø125 mm 327647 Wood rack Unilux-3 40 - high model - h = 60 mm 328059 Wood rack Unilux-3 52 - high model - h = 60 mm 327648...
UNILUX-3 40 / 52 / 55 / 65 INSTALLATION INSTRUCTIONS FITTING THE FIREPLACE When fi tting one of these fi replace inserts local and/or national regulations relating to fi re safety must be followed. In case of doubt, consult the fi re safety department of the local fi...
Page 15
UNILUX-3 40 / 52 / 55 / 65 FITTING Without frame (Integrated frame side strip and top strip) 3 sided frame 4 sided frame Directions for use and Installation Instructions...
Page 16
UNILUX-3 40 / 52 / 55 / 65 A fi replace insert can be fi tted in the newly-built or existing chimney breast of an open fi re. When fi tting, both fi re safety and operational safety must be safeguarded.
Page 17
UNILUX-3 40 / 52 / 55 / 65 In dwellings with an operating extractor hood, this should be turned to the lowest setting or turned off altogether. If the extractor hood remains in use, additional ventilation must be provided in compensation. This will not only avoid poor combustion, but will also prevent fl...
Page 18
UNILUX-3 40 / 52 / 55 / 65 3.3.3 Fitting in a newly-built chimney breast • If required, a convection set can be added when installing the appliance. (Not applicable for Unilux-3 40.) • Use convection set: The function of the convection set (option) is to improve the convection through the appliance, resulting in effi...
Page 19
UNILUX-3 40 / 52 / 55 / 65 ° Now connect the fl exible hoses to the 2 collar adaptors (Ø125 mm) on the top of the fi re and to the metal fi tting box on the air exit grids that are being used (do not forget to fi...
Page 20
Figure 2: Use of convection set and ventilation of fi replace Unilux-3 52/55/65 • Close up the front. Unilux-3 40: The appliance has its own intake and discharge openings for the convection air. Unilux-3: The appliance has its own intake and discharge openings for 52/55/65 the convection air.
Page 21
UNILUX-3 40 / 52 / 55 / 65 Available BARBAS grids (option) for ventilating the fi replace: COLOUR DIMENSION (cm) CLEAR OPENING (cm Brass or white 13.5 x 13.5 (incl. fi tting) Brass or white 27.0 x 13.5 (incl. fi tting) Perma Air (white) 43.0 x 22.0...
Page 22
UNILUX-3 40 / 52 / 55 / 65 • Disassembling the smoke outlet top-connection. • Pull the stovepipe or the stainless steel (fl exible) pipe downwards through the appliance and secure it to the smoke outlet connection. Stainless steel fl exible...
Page 23
UNILUX-3 40 / 52 / 55 / 65 Fix with hose clamp (Minimum 2 pieces per connection.) Stovepipe of steel • Push the smoke outlet connection back upwards and secure it in place. • Replace the brake plate, the complete interior and fl ue gas fl ap.
UNILUX-3 40 / 52 / 55 / 65 STOKING UP FOR THE FIRST TIME If you have had your chimney breast modifi ed or newly built, fi rst allow your home to dry properly. Walls which have not been allowed to dry properly are a magnet for dust such as any smoke particles created when stoking up the fi...
UNILUX-3 40 / 52 / 55 / 65 VENTILATION Air is a vital component of the combustion process. Ensure that there is a suffi cient supply of fresh air. For each kilo of wood that you put on the fi re (door closed), 10 - 15 m of extra air is needed.
UNILUX-3 40 / 52 / 55 / 65 When setting the fi re, move the locking slider all the way to the left. If necessary, leave the door ajar for 10 minutes. Do not open the door wide, as the window will remain cold.
Page 29
When loading the fi re with fuel, two blocks measuring 15 cm long and 30 cm perimeter (Unilux-3 40), (35 cm perimeter (Unilux-3 52 and Unilux-3 65)), (40 cm perimeter (Unilux-3 55)) is suffi cient. Do not add more fuel until the previous fuel has burned down to the charcoal stage.
UNILUX-3 40 / 52 / 55 / 65 Modifi cation Do not make modifi cations to your fi re. Any alteration to your fi re, of whatever nature, will also invalidate your warranty. Continuous stoking with the primary air supply open (combustion air supply slider is right over to the “...
UNILUX-3 40 / 52 / 55 / 65 GENERAL HINTS TIPS • Burn dry wood only. Damp wood not only burns poorly, it causes more pollution in the appliance (window), the chimney, your room (when opening the door of the appliance, for instance) and the environment. Wood can only be classifi...
UNILUX-3 40 / 52 / 55 / 65 • Chimney fi re. If, despite all the precautions, a fi re should occur in the chimney (you generally notice that because of a roaring sound in the chimney), do the following: •...
Page 33
UNILUX-3 40 / 52 / 55 / 65 • Excessive chimney draught. The combustion air does not reach the fuel, but leaves the appliance via the chimney. The fi re cools and the combustion quality decreases. • Using too much wood.
UNILUX-3 40 / 52 / 55 / 65 FUELS The appliance has been recommended as suitable for use in smoke control areas when burning the suitable fuels mentioned hereunder. WOOD Suitable fuels are: • All sorts of clean wood (forested). The wood must have been dried for at least two years.
fi re, the hotter it will become and overheating may even occur. If this happens, there is a risk of fi re. It may also damage your appliance and chimney. BARBAS will not assume liability for damage caused by overheating.
Page 36
UNILUX-3 40 / 52 / 55 / 65 Unilux-3 52 / 65: Per fi lling: (= for 45 minutes) Wood: 2 blocks, each around 0.75 kg Briquettes: 3 briquettes, each around 0.35 kg Dimensions wood block: c. 15 cm long and 35 cm perimeter (≈...
Page 37
UNILUX-3 40 / 52 / 55 / 65 HEAT RADIATION The table below shows the temperatures which can theoretically be achieved by burning wood. Heat radiation Sort of fuel kWh/kg Dry wood (average) The heating value of wood (18.7 MJ/kg at 0% humidity) is not affected by the sort of wood.
UNILUX-3 40 / 52 / 55 / 65 REGULAR MAINTENANCE • Emptying the ashtray Weekly, 48 hours after last heating • Cleaning the glass As required • Door and ashtray seals Check annually before heating is resumed. Replace as necessary •...
Page 42
UNILUX-3 40 / 52 / 55 / 65 Sequence for replacing the interior of the appliance: Remove the grate and ashtray. Remove the wood rack. - Remove the bottomplate in the front. Remove the fl ue gas fl ap by lifting it slightly, tipping it backwards and removing it.
Page 43
UNILUX-3 40 / 52 / 55 / 65 Remove the brake plate holder Temporarily place the brake plate (metal strip, front of brake plate). one notch higher in the appliance. Remove the right-hand side panel. To do this, lift the brake plate slightly.
Page 44
UNILUX-3 40 / 52 / 55 / 65 Remove the left-hand side panel. Remove the rear panel. The entire interior is now disassembled. The interior is reassembled in the reverse order. Directions for use and Installation Instructions...
Can a wood-burning stove/fi replace insert be connected to a central heating installation? The Barbas range does not have any stoves/fi res that can be connected to central heating installations. We do not advise attempting it!! Directions for use and Installation Instructions...
Page 51
UNILUX-3 40 / 52 / 55 / 65 How do I know if I’m heating correctly? Follow the instructions in this manual. The fl ames should play softly across the wood and the wood should burn evenly. Once the fi re has been burning for a short time, the smoke from the chimney should be almost translucent.
UNILUX-3 40 / 52 / 55 / 65 There may be too much of a draught in your chimney, particularly if it is very high (in excess of 8 m). Ask your supplier to fi t a check valve or damper. This may not be possible in all cases.
Page 53
UNILUX-3 40 / 52 / 55 / 65 What happens when wood is burnt? The combustion process. The combustion of wood involves the following steps. Drying The fi rst step is that the fuel (wood) dries out. Even at low temperatures (~ 100°C), any moisture still in the wood will evaporate.
Page 54
UNILUX-3 40 / 52 / 55 / 65 Directions for use and Installation Instructions...
Need help?
Do you have a question about the Unilux-3 40 and is the answer not in the manual?
Questions and answers