Function Descriptions
command so that subjects that are at approximately
1m TELE edge (When the Near Limit is 1m) are in
focus.
In the same way that 0 sets the level to OFF, the
larger the number, the greater the offset.
Focus Area
The areas of FOCUS AREA command is determined
as below.

[3] White Balance Control

ATW
Auto Trace White Balance.
SMART ATW
This mode controls retracing of ATW according
to the size of single-color object in the screen,
addition to normal ATW mode control.
In case the single-color object covers most of
the area in the screen, WB control function shall be
stopped.
*This mode is valid when WB mode is set to ATW.
AWC
The Push-Lock Auto White Balance starts retracing
using the One Push Trigger command and locks the
white balance after approximately 2 seconds.
After executing the One Push Trigger command, the
mode returns to the previous mode by executing the
AWC Reset command.
MWB MODE in AWC
Retrieve the result by One-Push WB(AWC) and
retain the value for manual adjustment.
After getting in to this mode, manual adjustment will
be available in MWB mode.
3200K
Color temperature 3200K fixed mode.
5600K
Color temperature 5600K fixed mode.
FLUO
Color temperature 4200K fixed mode.
Full Image Area
1: Entire Screen
2: Mid Area(DEFAULT)
3: Center
MWB
Manual White Balance. The R and B gains can each
be configured to a range of 0 to 255.

[4] IRIS Control

Auto Iris
The lens aperture is automatically controlled to
correct the brightness of the average luminance
value of the image.
Manual Iris
This fixes the lens aperture. The aperture position
can be set to a range of 17 levels (1: close - 17:
open) using the Manual IRIS Stop command.
EI ON
The light intensity can be controlled to a fixed level
using an electronic shutter control.
Note: Executing the EI ON command sets the
shutter speed mode to OFF.
EI OFF
This fixes the electronic shutter. Refer to the
Shutter Speed Control regarding fixed values.
Iris Level
The target brightness can be configured to a range
of 0 to 100.(0:dark - 100:bright)

[5] Shutter Speed Control

Prolonged Exposure Mode
The exposure time is longer than 1 field.
The field accumulation time can be configured from
1x to 64x.
However, this cannot be configured during the
following conditions.
When SENSE UP is enabled.
When MOTION settings are enabled.
When EI is ON.
Normal Mode
Will be adjusted to 1/30(1/25).
High-Speed Shutter Mode
This can be configured from 1/60 to 1/10000.
Note 1) If flickering is noticeable in regions with
a power supply frequency of 50Hz when
using NTSC, switch to the High-Speed
Shutter Mode (1/100).
Note 2) When switching to the Prolonged Exposure
or High-Speed Shutter Mode, transmit the
"Shutter Speed Set Mode" command after
the "Shutter Long Direct" or "Shutter Short
Direct" command.
SENSUP