Wireless DMX
Linking

Starting Address

Master/Slave
Mode
DMX
Personalities
Freedom™ Par Quad-4 IP User Manual Rev. 1
The Freedom™ Par Quad-4 IP operates by itself in Standalone mode.
It also operates in Master/Slave mode, or in Wireless DMX mode, both of which require wireless DMX
linking. In Master/Slave mode the master product sends wireless DMX signals to the slaves. In Wireless
DMX mode a lighting control board or D-Fi™ product must send wireless DMX signals to the products.
To DMX-link a number of Freedom™ Par Quad-4 IP using wireless D-Fi™, see
Mode Manual
Sync).
Information about DMX is in the DMX Primer, which is available from the Chauvet website
www.chauvetlighting.com/download/.
To ensure full access to all channels in each DMX mode, the highest recommended DMX address is 503.
Master/Slave mode allows a single Freedom™ Par Quad-4 IP (the master) to wirelessly control the
actions of one or more Freedom™ products (the slaves) without a DMX controller.
The master will be set to operate in either an auto program, static color, or custom color mixing mode,
while the slaves will be set to operate in wireless DMX receiver mode. Once set, the slaves will operate in
unison with the master. Configure the units as indicated below.
Slaves:
1.
Press <MENU> repeatedly until any DMX personality shows on the display.
2.
Press <ENTER>.
3.
Set the DMX address to d 1.
4.
Press <MENU> repeatedly until S-tr shows on the display.
5.
Use <UP> and <DOWN> to select drCH.
6.
Press <ENTER>.
7.
Use <UP> and <DOWN> to select a receiving channel dr 1–dr16.
8.
Press <ENTER>.
9.
Finish setting all the slaves.
Note: All slaves must be set to the same DMX personality and D-Fi™ channel.
Master:
1.
Press <MENU> until the DMX personality the slaves are set to shows on the display.
2.
Press <ENTER>.
3.
Set the DMX address to d 1.
4.
Press <MENU> repeatedly until S-tr shows on the display.
5.
Use <UP> and <DOWN> to select dtCH.
6.
Press <ENTER>.
7.
Use <UP> and <DOWN> to select the transmitting channel (dt 1–dt16) the slaves are set to.
8.
Press <ENTER>.
9.
Set the master to run in auto program, static color, or custom color mixing mode.
Never transmit a DMX signal from a controller over a D-Fi™ channel being used for Master/Slave.
When selecting a starting DMX address, always consider the number of DMX channels the selected DMX
mode uses. If you choose a starting address that is too high, you could restrict the access to some of the
product's channels.
If unfamiliar with DMX, download the DMX Primer from www.chauvetlighting.com.
To select the DMX personality and starting address, do the following:
1.
Press
<MENU>
repeatedly
10CH (10-channel mode) shows on the display.
2.
Press <ENTER> and d 1–d512 shows on the display.
3.
Use <UP> or <DOWN> to select the starting address.
4.
Press <ENTER>.
until
3-CH
(3-channel
D-Fi™ 2.4 GHz (DMX
mode),
6-CH
(6-channel
mode)
or