SEAGULL
Drinking Water Purification System
INSTALLATION AND PRODUCT USE GUIDE

Installation Instructions

NOTE: Read instructions completely before starting.
General Ecology's X-1F drinking water purification system is designed to operate at pressures ranging from 25 to 125 psi. If pressure
surges are a possibility (municipal water supplies), install a Pressure Regulator or Surge Protector on the cold water supply line. This
system is intended to be installed to the cold water supply line, downstream of and above the cold water shut-off valve inside the
kitchen sink cabinet (see page 4). Be sure to close supply valves before installation. The Connector Hose will fit an Owner-Supplied
Connector T or our optional Saddle T Assembly or Male Run T shown on page 4. Connector branch of Owner Supplied T must have
a a a a a " Male Compression Thread ( h
1½" diameter hole is necessary for mounting the easily installed special Faucet furnished with this unit.
Follow steps 1 through 9 for installation. Steps A through F are cartridge replacement instructions. An order blank is included for
assistance in obtaining replacement Cartridges. Configuration specifications are shown at the end of this guide.
IV X-1F
®
h
h " - 24 Thread). The cold water supply line should be clean and free of construction debris. A p p p p p " to
h h
supersedes 200712Ax-1f-i&o

Advertisement

loading
Need help?

Need help?

Do you have a question about the IV X-1F and is the answer not in the manual?

Questions and answers

Summary of Contents for Seagull IV X-1F

  • Page 1: Installation Instructions

    200712Ax-1f-i&o SEAGULL IV X-1F ® Drinking Water Purification System INSTALLATION AND PRODUCT USE GUIDE Installation Instructions NOTE: Read instructions completely before starting. General Ecology’s X-1F drinking water purification system is designed to operate at pressures ranging from 25 to 125 psi. If pressure surges are a possibility (municipal water supplies), install a Pressure Regulator or Surge Protector on the cold water supply line.
  • Page 2: General Installation Instructions

    General Installation Instructions ® Please retain for future servicing of your SEAGULL IV Water Purifier Preliminary: If needed purchase from local hardware store and install Connector T or Saddle Valve with a" compression outlet in cold water supply line. Figure...
  • Page 3: Cartridge Replacement Instructions

    Cartridge Replacement Instructions ® All Seagull IV X-1 units employ a RS-1SG Cartridge. The rated average capacity for the RS-1SG Cartridge is 1,000 gallons. Actual capacity will vary depending on operating conditions and the quality of the water source. Cartridges should be replaced when the flow rate decreases or when foul tastes or odors become apparent (evidence of extra heavy loading of sulfur, tannin, iron or contamination), or annually otherwise.
  • Page 4 SEAGULL IV X-1F System Parts List ® Description Qty. Part No. Female Compression Thread 800344 a" Braided Connector Hose Mounting bracket with 2 700063 Mounting screws Purification 788000 Cartridge RS-1SG X-1 Pressure Vessel Housing Gasket 710540 V-Clamp for Housing 710534...
  • Page 5 The Seagull IV X-1P configuration has a double acting pump for more water with less work. Field serviceable pump disassembles for easy cleaning and permits the X-1P water purifier to be used with gravity feed assistance systems.
  • Page 6 SEAGULL ® IV X-1F Positioning and Faucet Care Instructions Dimension Information All General Ecology, Inc. purifiers feature lead free ports and faucets. Faucets are manufactured with the finest components available. Cut out faucet base pattern and use for rough position. Tape pattern However, they require proper care to keep them looking their best.