HERALD 4
Wood Burning Stove
Installation and Operating Instructions
JINHH04WB RevA 27/04/12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HERALD 4 and is the answer not in the manual?

Questions and answers

Summary of Contents for Hunter Stoves HERALD 4

  • Page 1 HERALD 4 Wood Burning Stove Installation and Operating Instructions JINHH04WB RevA 27/04/12...
  • Page 2 Herald 4 Technical Specification Appliance Mass 88 kg Total Efficiency 78.0 % 4.0 kW Nominal Heat Output 0.44 % Mean CO Emission (@13% O Mean Flue Gas Temperature 246 °C Flue Gas Mass Flow 3.8 g/s This appliance is not for use in shared flue...
  • Page 3: General Guidance

    Some types of fire cement are caustic and Competent Persons Scheme should not be allowed to come into contact Hunter Stoves recommend that this stove is with the skin. In case of contact, wash installed by a member of an accredited immediately with plenty of water.
  • Page 4 Never leave the stove unattended for long Metal Parts periods without first adjusting the controls to a When installing or servicing this stove, care safe setting. should be taken to avoid the possibility of personal injury. Careful air supply control should be exercised at all times.
  • Page 5 advise on solutions to this problem (e.g. anti- downdraught cowl). Do not fit an extractor fan in the same room as this appliance. CO Alarm Your installer should have fitted a CO alarm in the same room as the appliance. If the alarm sounds unexpectedly, follow the instructions given under “Warning Note”...
  • Page 6: Assembly Instructions

    Assembly Instructions OLLAR AND LANKING LATE Wind the eight M6 studs supplied into the fixing holes in the flue collar and blanking plate until finger tight. Place a flue outlet gasket in position on the top plate of the stove and lower the flue collar or blanking plate (as required) on to the stove top, taking care to line up the studs with the fixing holes.
  • Page 7: Installation Instructions

    Connection to the Chimney Installation The chimney must be swept before connection Instructions to the stove. An existing fireplace opening can be bricked up or sealed with a register plate. Chimney The chimney height and the position of the A short length of flue pipe of minimum 125mm chimney terminal should conform to Building internal diameter may then be used to connect Regulations.
  • Page 8: Air Supply

    Air Supply Minimum Distances to Combustible Material Behind the stove 650mm The room or space containing this appliance At the side of the stove 400mm should have purpose provided ventilation In front of the stove 900mm (where necessary) in accordance with Building Regulations.
  • Page 9: Aerosol Sprays

    Secondary Air Operating Secondary air is controlled via the slider above the door; it is this “Airwash” that keeps a clean Instructions and uninterrupted view of the fire. The amount of air can be increased by moving the slider to the right.
  • Page 10 If there is insufficient burning material in the the firebox. Close the door and allow the fuel firebed to light a new fuel charge, excessive and stove to cool before attempting to relight smoke emission can occur. the fire. Refuelling must be carried out with a sufficient N.B.
  • Page 11: Recommended Fuels

    Recommended Fuels Hunter Stoves recommend that wood logs are burnt in this appliance. Burn only dry, well-seasoned wood, which should have been cut, split and stacked for at least 12 months, with free air movement around the sides of the stack to enable it to dry out.
  • Page 12: General Maintenance

    Do not clean whilst the stove is hot. Rope The finish can be renovated with Hunter Stoves Check the rope around the door. If rope is becoming detached, use Hunter Stoves rope paint.
  • Page 13: Troubleshooting

    Only wire-centred sweeps’ brushes fitted with a This is due to a reduction in the pigment used in guide wheel should be used. the manufacture of the product and no cause for concern. If it is not possible to sweep all parts of the chimney through the appliance, ensure there is Troubleshooting adequate access to cleaning doors.
  • Page 14: Spares Information

    Spares Information Single Door spares Single Door (HH04/055) Door Glass (HH04/057) Door Handle (HCR06/059) Slider Knob (HHR08/045) Door Cover (HH04/056) Door Catch Assembly Rope Sealing Kit (DCH4) (SCPH4SDSK) Glass Gasket Glass Clip (HH04/058) (HHR08/046) Glass Clip Screw Door Slider (FSJM05008SS) (CH05/009) JINHH04WB RevA 27/04/12...
  • Page 15 Double Door spares Door Glass Right Hand Door (HH04/073) (HH04/069) Right Hand Glass Gasket Door Cross (HH04/072) (HH04/071A) Glass Clip Door Catch Assembly Door Handle (HHR08/046) (DCH4) (HCR06/059) Glass Clip Screw (FSJM05008SS) Slider Knob (HHR08/045) Rope Sealing Kit Door Slider (SCPH4NDSK) (HH04/091) Left Hand Door...
  • Page 16 Body Assembly Spares – Wood Flue Gasket (CH05/042) Recouping Baffle Hinge (HH04/125) (HH06/050) Hinge Pin (FRRE08-1.75) Tertiary Air Bar (HH04/105) Side Brick (HH04/116) Catch Bar Rear Brick Single Door (HH04/115) (HH04/127) Double Door (HH04/114) Operating Tool (HFR07/040) JINHH04WB RevA 27/04/12...