Condition
Pumping action produces no pressure
Lever can be operated with little
resistance
Lever jammed or difficult to move
downwards
Unit sprays only while pumping
Nozzle does not spray – pressure in
container OK
Liquid drips from nozzle
Jet only – spray not atomized
1)
STIHL recommends an authorized STIHL servicing dealer.
18
Cause
Pump barrel damaged
Valve disks damaged
Piston cup seal damaged
Piston cup seal not lubricated
Nozzle / filter plugged
Pressure vessel full of liquid
Nozzle / filter plugged
Nozzle / filter plugged
Nozzle dirty
Remedy
Install new pump barrel
Have valve disks replaced
Have piston cup seal replaced
Lubricate piston cup seal with grease
Clean nozzle / filter
Pump until unit is completely empty
Repeat after no more than 5 refills
Clean nozzle / filter
Clean nozzle / filter
Clean nozzle