Sanyo PLC-XU47 Service Manual page 15

Hide thumbs Also See for PLC-XU47:
Table of Contents

Advertisement

Optical Parts Disassemblies
n
Polarized Glasses-Out removal
1
A
Remove 1 screw
and remove the holder
glasses (R) and (B).
2
B
Remove 1 screws
and remove the stopper
ized glass (G) and pre-polarized glass (G).
3
C
Remove 1 screws
and remove the stopper
then take the pre-polarized glass (B).
Note:
Projector may not provide the Pre-polarized glasses
(R) and (G) depending on the models.
A
and then take the polarized
B
and then take the polar-
C
and
Holder A
A
Polarized Glass(B)
Polarized Glass(R)
* Mount the polarized glasses
as the film attached side
comes to the LCD panel side.
-15-
Pre-Polarized Glass(B)
Stopper C
C
Stopper B
B
Polarized
Glass(G)
Pre-
Polarized
Glass(G)
Fig.6

Advertisement

Table of Contents
loading

This manual is also suitable for:

1 122 280 001 122 281 001 122 281 02

Table of Contents