5.37.36 Query the defense zone type
Syntax :[1234]+[60]+[zone number 01-99]+[#]。
5.37.37 Query the alarm mode of the wired zone
Syntax : [1234]+ [61]+[zone number 51-52]+[#]。
5.37.38 SMS message content setting
Syntax : [1234]+[80]+[zone number 01-99]+[Content] +[#],
th
Example : set the 60
12348060front door open #。
5.37.39 Query the SMS message content of every zone
Syntax : [1234]+[81]+[zone number 01-99] +[#]。
5.38
Remote Control of Panel
Remote-control operations can be done via any phone. You can just dial into the alarm panel and user
will be asked for password upon connected and alarm will automatically hang up call if password is
incorrect. (original password 1234)
[1] key: arming
[3] key: monitoring open
[5] key: turn on announcement
[7] key: siren ringing
[*] key: hang up, system will not dial the next number on list.
Remark:
-
Monitoring time and announcement time is 20s ,if you want to continue ,please press 3 or 5 within
20s .
5.39 System default zone types are:
Normal
Stay
01-59
60-79
5.40 System default setting
Operation password
Remote Control
Siren sound
Delay ARM
Cut-line detect
51-52 wired zones
5.41 Fitting parameters:
Input voltage: DC9V-12V
Standby currents:<25mA
Alarm current: <450mA
Wireless frequency : 315/433MHz
GSM frequency :GSM850/900/1800/1900MHz
Back-up battery:Ni-MH AAA*6
Alarm loudness:110dB
zone message content as : front door open ,send the message to the alarm panel :
[2] key: disarming
[4] key: monitoring closed
[6] key: turn off announcement
[8] key: stop siren sound
Intelligent
Help Senior
80-89
90
1234
SMS message
Enable
Number of ring tones before picking up
1 minute
Audible confirmation for remote operation
0 s
Delay alarming
Off
1-99 zone alarming
NO
1-99 Zone SMS message content
DC7.24V
Chime
91
22
Welcome
Emergency
92
93-99
Enable
8 times
Enable
0s
Siren sound
Zone alarm
Need help?
Do you have a question about the DP-8218G and is the answer not in the manual?