Electrical Adjustment
Grp / No.
Item
11
DIMMER_CTRL_LEVEL10
12
DIMMER_CTRL_LEVEL11
13
DIMMER_CTRL_LEVEL12
14
DIMMER_CTRL_LEVEL13
15
DIMMER_CTRL_LEVEL14
16
DIMMER_CTRL_LEVEL15
17
DIMMER_AVERAGE_POINT
18
DIMMER_AVERAGE_DATA
19
DIMMER_LEVEL_AUTO
20
DIMMER_LEVEL_NORMAL
21
DIMMER_LEVEL_ECO
23
VOLTAGE_LEVEL
24
DIMMER_LEVEL_HIGH
220
Projector Error Log
0
Warning_Log_1
:
:
49
Warning_Log_50
50
Warning_Log Reset
235
Shutter
0
PRE_MOTION
1
CMP_TRM
2
OUT_DLY_TRM
3
CMP_CHK_CNT
4
OPEN_DLY
5
CLOSE_DLY
6
Position Check Time
7
Stop Mode
8
Enable Close Cmd
236
Lamp Mode Switch
0
2 Lamp Mode
1
Lamp1 Mode
2
Lamp2 Mode
240
Flow Calibration
0
Flow Calibration Exe
1
Flow Calibration Error Log
2
Clog Check Enable
241
Flow Ideal Data
0
Flow Ideal Data 1
1
Flow Ideal Data 2
2
Flow Ideal Data 3
3
Flow Ideal Data 4
4
Flow Ideal Data 5
5
Flow Ideal Data 6
6
Flow Ideal Data 7
7
Flow Ideal Data 8
242
Flow Calib. Fan Volt
0
Flow Calib Fan Volt 1
1
Flow Calib Fan Volt 2
2
Flow Calib Fan Volt 3
3
Flow Calib Fan Volt 4
4
Flow Calib Fan Volt 5
5
Flow Calib Fan Volt 6
6
Flow Calib Fan Volt 7
7
Flow Calib Fan Volt 8
Function
Y Level10 Data for Dimmer
Y Level11 Data for Dimmer
Y Level12 Data for Dimmer
Y Level13 Data for Dimmer
Y Level14 Data for Dimmer
Y Level15 Data for Dimmer
Y Average Point
Y Average Data (Read only)
Current Y Level (Read only)
Dim Level at Normal
Dim Level at Eco
Lamp Voltage (Read only)
Dim Level at High
Latest Error log
:
50th Error log
Log is cleared when the value is set to 10.
Shutter Warm - up Operation (0: Yes, 1: No)
Chattering Detecting Term
Output Term
Count of Information Sync
Open Output Delay
Close Output Delay
Position Check Time
Shutter Operation in Stop Mode
0:Free, 1:Brake
Shutter Close Command
0:Disable, 1:Enable
Flow Sensor Offset Calibration Start calibration when the value
is set to 1.
Log of Calibration Error (Read only)
255: Not Calibration
0: No Error
10: 1st Calibration Not Stable Airflow
11: 1st Calibration Out of Range
20: 2nd Not Stable Airflow
21: 2nd Out of Range
100: 10th Calibration Not Stable Airflow
101: 10th Calibration Out of Range
Filter Clogged Detection by Flow Sensor (0: Disable, 1: Enable)
(Value will be set after calibration)
Flow Sensor Theory Value No.1 Corresponding to Fan Volt No.1
Flow Sensor Theory Value No.2 Corresponding to Fan Volt No.2
Flow Sensor Theory Value No.3 Corresponding to Fan Volt No.3
Flow Sensor Theory Value No.4 Corresponding to Fan Volt No.4
Flow Sensor Theory Value No.5 Corresponding to Fan Volt No.5
Flow Sensor Theory Value No.6 Corresponding to Fan Volt No.6
Flow Sensor Theory Value No.7 Corresponding to Fan Volt No.7
Flow Sensor Theory Value No.8 Corresponding to Fan Volt No.8
(Not Memorized)
Flow Sensor Calibration Fan Volt No.1 [V x10]
Flow Sensor Calibration Fan Volt No.2 [V x10]
Flow Sensor Calibration Fan Volt No.3 [V x10]
Flow Sensor Calibration Fan Volt No.4 [V x10]
Flow Sensor Calibration Fan Volt No.5 [V x10]
Flow Sensor Calibration Fan Volt No.6 [V x10]
Flow Sensor Calibration Fan Volt No.7 [V x10]
Flow Sensor Calibration Fan Volt No.8 [V x10]
Range
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
1 - 16
-
-
0 - 15
0 - 15
-
0 - 15
0 - 32767
:
0 - 32767
0 ~ 10
0 - 1
0 - 32767
0 - 32767
0 - 15
0 - 63
0 - 63
1 - 255
0 - 1
0 - 1
0 - 99
0 - 99
0 - 99
0 - 1
-
0 - 1
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
-51-
Initial
Note
70
77
84
91
98
105
4
-
-
8
0
-
15
0
:
0
0
Initial: 1 / Shipping: 0
7000
15000
5
30
30
20
1
1
0
0
0
0
255
Initial: 0 / Shipping: 1
377
486
513
538
563
1023
1023
1023
65
95
110
125
138
255
255
255

Hide quick links: