9-10 eC deCLARATION OF CONFORMITy Trakis Nagykoros Kft declares that the following machines: Classic MIG 160 / 200 / 300 / 300S blue brand MIG 160 / 200 / 300 /300S correspond to the following edicts and standards: MSZ eN 60974-1:2006...
Page 3
wARNING Fume welding vaporises metals, and anything that is resting on the surface. This gives rise to fume, which is condensed find particulate material. The fume is mostly oxides of the metals, including any alloying elements, but it also contains gases produced in the arc, such as ozone or oxides of nitrogen, and decomposition products from any paints or coating which was on the metal surface.
INSTALLATION electrical Connection The migs comprise of three models, all single phase. Always ensure the machine is connected to the correct supply, with the correct size of fuses or circuit breakers as shown below. If circuit breakers are used they must be type four otherwise tripping may occur although there is no machine fault.
OpeRATION Controls On/Off Switch Is the illuminated rocker switch which lights up red when the machine is switched on. Voltage Control 160 has six voltage settings 1 being the lowest. Switch 200 has eight voltage settings 1 being the lowest. Voltage Control 300 / 300S the left-hand switch has two settings which alters Switch voltage output in large steps, the right-hand switch has eight...
TROUbLeShOOTING FAULT ReASON ReMedy Set is dead 1. On/Off switch is off Turn it on 2. Fuse in mains supply blown Replace fuse Nothing happens when 1. Torch switch defective Check for torch fault by shorting the torch trigger is pressed 2.
Need help?
Do you have a question about the MIG 160 and is the answer not in the manual?
Questions and answers