Panasonic S-12MU1U6 Operating Instructions Manual
Panasonic S-12MU1U6 Operating Instructions Manual

Panasonic S-12MU1U6 Operating Instructions Manual

Vrf system air conditioner
Hide thumbs Also See for S-12MU1U6:

Advertisement

85464609162011_Cover.fm Page 2 Wednesday, September 21, 2011 11:44 AM
* Shows U1 type
Model No.
Indoor Units
Type
Indoor Unit Type
U1
4-Way Cassette
Y1
4-Way Cassette 60x60
D1
1-Way Cassette
S-07MD1U6 S-09MD1U6 S-12MD1U6
F1
Low Silhouette Ducted
S-07MF1U6 S-09MF1U6 S-12MF1U6 S-15MF1U6 S-18MF1U6
M1
Slim Low Static Ducted
S-07MM1U6 S-09MM1U6 S-12MM1U6 S-15MM1U6 S-18MM1U6
High Static Pressure
E1
Ducted
T1
Ceiling
K1
Wall Mounted
S-07MK1U6 S-09MK1U6 S-12MK1U6
P1
Floor Standing
S-07MP1U6 S-09MP1U6 S-12MP1U6 S-15MP1U6 S-18MP1U6
R1
Concealed Floor Standing
S-07MR1U6 S-09MR1U6 S-12MR1U6 S-15MR1U6 S-18MR1U6
* Necessary to install the External Electronic Expansion Valve Kit (Optional : CZ-P56SVK1U)
Outdoor Units
3WAY VRF System
U-72MF1U9, U-96MF1U9, U-72MF1U9E
2WAY VRF System
U-72ME1U9, U-96ME1U9, U-72ME1U9E
Mini VRF System
U-36LE1U6, U-52LE1U6, U-36LE1U6E
*1 Salt-Air Damage Resistant Specifications.
Remote Controllers
Timer Remote Controller
Wireless Remote Controller (for F1, M1, E1, P1, R1 type)
Wireless Remote Controller (for U1 type)
Wireless Remote Controller (for Y1 type)
Wireless Remote Controller (for D1, T1 type)
Wireless Remote Controller (for K1 type)
* Timer Wired Controller comes with Operating Instructions.
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
85464609162011
7
9
12
15
S-12MU1U6
S-12MY1U6
S-12MT1U6
CZ-RTC2
CZ-RWSC1U
CZ-RWSU1U
CZ-RWSY1U
CZ-RWST1U
CZ-RWSK1U

Operating Instructions

VRF System Air Conditioner
18
19
24
S-18MU1U6
S-24MU1U6 S-36MU1U6
S-18MY1U6
S-24MF1U6 S-36MF1U6 S-48MF1U6 S-54MF1U6
S-18MT1U6
S-24MT1U6
S-18MK1U6 S-19MS1U6* S-24MK1U6
S-24MK1U6
S-24MR1U6
*1
*1
, U-96MF1U9E
*1
, U-96ME1U9E
*1
*1
, U-52LE1U6E
*1
This air conditioner uses the refrigerant R410A.
36
48
54
S-36ME1U6 S-48ME1U6
CV6233186948

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic S-12MU1U6

  • Page 1: Operating Instructions

    85464609162011_Cover.fm Page 2 Wednesday, September 21, 2011 11:44 AM Operating Instructions VRF System Air Conditioner * Shows U1 type Model No. Indoor Units Type Indoor Unit Type 4-Way Cassette S-12MU1U6 S-18MU1U6 S-24MU1U6 S-36MU1U6 4-Way Cassette 60x60 S-12MY1U6 S-18MY1U6 1-Way Cassette S-07MD1U6 S-09MD1U6 S-12MD1U6 Low Silhouette Ducted...
  • Page 2: Table Of Contents

    162011_VRF_EN.fm Page 2 Friday, September 30, 2011 9:27 AM CONTENTS Page PRODUCT INFORMATION ......................2 ALERT SYMBOLS.........................2 INSTALLATION LOCATION......................3 ELECTRICAL REQUIREMENTS ....................3 SAFETY INSTRUCTIONS......................3 NAMES OF PARTS (INDOOR UNIT) ....................5 WIRELESS REMOTE CONTROLLER (OPTIONAL PARTS) ............6 NOTE Refer to the Operating Instructions attached to the optional Wireless Remote Controller.... 6 TIMER REMOTE CONTROLLER (OPTIONAL PARTS) ...............6 NOTE Refer to the Operating Instructions attached to the optional Timer Remote Controller....
  • Page 3: Installation Location

    162011_VRF_EN.fm Page 3 Friday, September 30, 2011 9:27 AM INSTALLATION LOCATION • We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit. • Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate.
  • Page 4: Operation Condition

    162011_VRF_EN.fm Page 4 Friday, September 30, 2011 9:27 AM • For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning or servicing. • Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply in case of emergency.
  • Page 5: Names Of Parts (Indoor Unit)

    162011_VRF_EN.fm Page 5 Friday, September 30, 2011 9:27 AM NAMES OF PARTS (INDOOR UNIT) INDOOR UNIT CASSETTE CEILING U1 type (4-WAY) T1 type Water drain Air outlet Water drain (You can Ceiling panel connect the (optional) drain pipe either the right Air outlet or left side.) (4 locations)
  • Page 6: Wireless Remote Controller (Optional Parts)

    162011_VRF_EN.fm Page 6 Friday, September 30, 2011 9:27 AM NAMES OF PARTS (INDOOR UNIT) (CONTINUED) INDOOR UNIT LOW SILHOUETTE DUCTED FLOOR STANDING F1 type (standard static pressure) P1 type Operation door Flexible duct (The remote controller (sold separately) (optional) can be placed inside here.) Water drain Air outlet Canvas duct...
  • Page 7: Adjusting Airflow Direction

    162011_VRF_EN.fm Page 7 Friday, September 30, 2011 9:27 AM ADJUSTING AIRFLOW DIRECTION 4-way (U1) and 1-way (D1) air conditioners are equipped with auto flaps. You can set the airflow direction to a specific angle or to the sweep mode using the remote controller.
  • Page 8 162011_VRF_EN.fm Page 8 Friday, September 30, 2011 9:27 AM ADJUSTING AIRFLOW DIRECTION (CONTINUED) Floor standing type (P1) It is possible to change the airflow direction. Remove the air discharge grille by sliding it to the right and then lifting it out. Turn the grille as desired (90, 180, or 270 degrees) and then replace it.
  • Page 9: Adjusting Airflow Direction For Multiple Indoor Units Using Single Remote Controller (Wired)

    162011_VRF_EN.fm Page 9 Friday, September 30, 2011 9:27 AM ADJUSTING AIRFLOW DIRECTION FOR MULTIPLE INDOOR UNITS USING SINGLE REMOTE CONTROLLER (WIRED) • The airflow direction cannot be set using the remote controller for the duct type (F1, M1, E1), and floor standing type (P1, R1). •...
  • Page 10: Care And Cleaning

    162011_VRF_EN.fm Page 10 Friday, September 30, 2011 9:27 AM CARE AND CLEANING 1. For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning. 2. Do not pour water on the indoor unit to clean it. This will damage the internal components and cause an electric shock hazard.
  • Page 11: Specifications

    162011_VRF_EN.fm Page 11 Friday, September 30, 2011 9:27 AM SPECIFICATIONS 4-Way Cassette Model Name S-12MU1U6 S-18MU1U6 S-24MU1U6 S-36MU1U6 Power Source Single-phase, 208-230 V, 60 Hz 10.6 Cooling Capacity BTU/h 12,000 19,000 25,000 36,000 11.4 Heating Capacity BTU/h 14,000 21,000 27,000...
  • Page 12 162011_VRF_EN.fm Page 12 Friday, September 30, 2011 9:27 AM SPECIFICATIONS (CONTINUED) Ceiling Model Name S-12MT1U6 S-18MT1U6 S-24MT1U6 Power Source Single-phase, 208-230 V, 60 Hz Cooling Capacity BTU/h 12,000 19,000 25,000 Heating Capacity BTU/h 14,000 21,000 27,000 Sound Pressure Level dB(A) 35/32/30 36/33/30 38/36/33...
  • Page 13 162011_VRF_EN.fm Page 13 Friday, September 30, 2011 9:27 AM SPECIFICATIONS (CONTINUED) Low Silhouette Ducted Model Name S-07MF1U6 S-09MF1U6 S-12MF1U6 S-15MF1U6 S-18MF1U6 S-24MF1U6 Power Source Single-phase, 208-230 V, 60 Hz Cooling Capacity BTU/h 7,500 9,600 12,000 15,000 19,000 25,000 Heating Capacity BTU/h 8,500 11,000...
  • Page 14 162011_VRF_EN.fm Page 14 Friday, September 30, 2011 9:27 AM SPECIFICATIONS (CONTINUED) Floor Standing Model Name S-07MP1U6 S-09MP1U6 S-12MP1U6 S-15MP1U6 S-18MP1U6 S-24MP1U6 Power Source Single-phase, 208-230 V, 60 Hz Cooling Capacity BTU/h 7,500 9,600 12,000 15,000 19,000 24,000 Heating Capacity BTU/h 8,500 11,000 14,000...
  • Page 15 162011_VRF_EN.fm Page 15 Friday, September 30, 2011 9:27 AM SPECIFICATIONS (CONTINUED) 3WAY VRF System Outdoor Unit Model Name U-72MF1U9 U-72MF1U9E* U-96MF1U9 U-96MF1U9E* Power Source 3-phase, 208-230 V, 60 Hz 21.1 21.1 28.1 28.1 Cooling Capacity BTU/h 72,000 72,000 96,000 96,000 23.7 23.7 31.6...
  • Page 16 162011_VRF_EN.fm Page 16 Friday, September 30, 2011 9:27 AM BE0711-10911 Printed in Japan...

Table of Contents