Ariston europrisma ep 10 or; europrisma ep 10 ur; europrisma ep 10 ur/2kw; europrisma ep 15 or; europrisma ep 15 ur; europrisma ep 15 ur/2kw; europrisma ep 30 r electric water heater (8 pages)
Summary of Contents for Ariston Unvented Hot Water Storage Cylinders
Page 1
www.tradeplumbing.co.uk Call Sales On 08708034288 Unvented Hot Instructions for Installation, Servicing and Use Water Storage LEAVE THESE INSTRUCTIONS WITH THE Cylinders END-USER www.tradeplumbing.co.uk Call Sales On 08708034288 Country of destination: GB/IE...
www.tradeplumbing.co.uk Call Sales On 08708034288 TABLE OF CONTENTS www.tradeplumbing.co.uk Call Sales On 08708034288 GENERAL INFORMATION 1.1 D ELIVERY INSTALLATION 2.1 W ATER EGULATIONS 2.2 B UILDING EGULATIONS 2.3 H OW THE PPLIANCE ORKS 2.4 O VERALL IMENSIONS 2.5 C ATER UPPLY 2.6 S ITING AND...
Failure to do so may invalidate the guarantee. The Ariston range is available in the following options: The Wall-hung ProTech range (50, 75, 100 litre models), which are supplied as follows;...
www.tradeplumbing.co.uk Call Sales On 08708034288 INSTALLATION ATER EGULATIONS UILDING EGULATIONS OW THE PPLIANCE ORKS www.tradeplumbing.co.uk Call Sales On 08708034288 These regulations (byelaws in Scotland) ensure a good supply of wholesome water, and that only approved materials, pipes and fittings are used to convey water.
www.tradeplumbing.co.uk Call Sales On 08708034288 VERALL IMENSIONS Model Storage Capacity DIRECT RANGE Wall-hung ST 50 ST 80 ST 100 100 l Floor Standing STD ProTech 100 l STD / STD ProTech / ITD 125 125 l STD / STD ProTech / ITD 150 150 l STD / STD ProTech / ITD 210 200 l...
www.tradeplumbing.co.uk Call Sales On 08708034288 ONNECTION OF AINS ATER UPPLY ST P 50-80-100 PRESSURE + TEMPERATURE RELIEF VALVE 15mm EXPANSION VESSEL COMBINATION HOT SUPPLY 15/22mm www.tradeplumbing.co.uk Call Sales On 08708034288 For floor standing models: On the front of the unit there is a label to identify the connection ports. Please check this before making any connection to the unit.
Page 7
www.tradeplumbing.co.uk Call Sales On 08708034288 STI/STI P /ITI 125-150-210-300 I COLD MAINS-IN 22mm COMBINATION VALVE HOT SUPPLY 22mm EXPANSION RELIEF PIPE SECONDARY RETURN ZONE VALVE TUNDISH FLOW 22mm DRAIN RETURN MAX. 100mm 500 STI P COLD MAINS-IN 28mm COMBINATION VALVE EXPANSION VESSEL HOT SUPPLY...
www.tradeplumbing.co.uk Call Sales On 08708034288 ATER OMBINATION ALVE SERVICEABLE 1/2” PRESSURE REDUCING CARTRIDGE AND LINE STRAINER 15mm COLD MAINS IN . 2.6 www.tradeplumbing.co.uk Call Sales On 08708034288 The cold water combination valve can be connected either close by the unit or alternatively it may be installed in a remote position from the unit as there is no requirement to site it in close proximity to the cylinder.
Page 9
www.tradeplumbing.co.uk Call Sales On 08708034288 22mm COLD MAINS IN SERVICEABLE 3/4” PRESSURE REDUCING CARTRIDGE AND LINE STRAINER (SET AT 3.5 BAR) 22mm COLD MAINS IN 22mm BALANCED COLD WATER TAKE OFF . 2.7 SERVICEABLE 1” PRESSURE REDUCING CARTRIDGE AND LINE STRAINER (SET AT 3.5 BAR) 28mm COLD MAINS IN...
www.tradeplumbing.co.uk Call Sales On 08708034288 ONNECTION TO ERVICES 2.10 ECONDARY ETURN 2.11 ISCHARGE IPEWORK www.tradeplumbing.co.uk Call Sales On 08708034288 It is recommended that a 22mm pipe run should supply the outlets throughout the building, especially to baths and showers. Short runs of 15mm pipe may be used to connect basins and sinks.
www.tradeplumbing.co.uk Call Sales On 08708034288 Temperature & pressure relief valve . 2.9 2. Sizing of copper discharge pipe “D2” for common temperature valve outlet sizes. ABLE Valve outlet size discharge pipe D1* G 1/2 G 3/4 www.tradeplumbing.co.uk Call Sales On 08708034288 connected.
www.tradeplumbing.co.uk Call Sales On 08708034288 calculate the next largest size. Maximum resistance allowed for a straight length of 28mm pipe (D2) from G temperature & pressure valve equates to: 18m. Subtract the resistance for 4 no. 28mm elbow at 1.0m each = 4m. Therefore the maximum permitted length equates to: 14m As the actual length is 7m, a 28mm (D2) copper pipe will be satisfactory.
Although the immersion heaters are a standard 2 ” thread, they must not be substituted with anything but an original Ariston spare part. HE IMMERSION HEATERS MUST NOT BE FITTED WITHOUT THE THERMOSTAT THERMAL DIRECT SYSTEMS A mains supply of 240V, 3kW (13 amps) is required.
www.tradeplumbing.co.uk Call Sales On 08708034288 2.11 LECTRICAL IAGRAM www.tradeplumbing.co.uk Call Sales On 08708034288 Should the Economy 7 system not to be used, a separate 13 amp supply to each element will be required. Through a double pole fused isolating switch having a contact gap of at least 3mm on each pole.The immersion heater shall be installed with 85°C rubber insulated HOFR-sheathed flexible cable complying with Table 8 of BS 6141: 1991.
Page 15
www.tradeplumbing.co.uk Call Sales On 08708034288 IRING T6360B ROOM THERMOSTAT BROWN BLUE GREY ORANGE GREEN/YELLOW V4043H HEATING VALVE BROWN BLUE GREY ORANGE GREEN/YELLOW V4043H HOT WATER VALVE 240V MAINS INPUT (3 AMP) Cylinder thermostat 240V www.tradeplumbing.co.uk Call Sales On 08708034288 MAINS INPUT (13 AMP) .
Page 16
www.tradeplumbing.co.uk Call Sales On 08708034288 ASIC OILER Baxi Glowworm Halstead Potterton Caradon Ideal Newflame Boilers Condensing Boiler List CARADON IDEAL GLOWWORM KESTON POTTERTON VAILLANT Boiler Connections Pump Connections www.tradeplumbing.co.uk Call Sales On 08708034288 Bermuda range Boston RS and OF range Complheat Hideaway range 65 - 80...
www.tradeplumbing.co.uk Call Sales On 08708034288 COMMISSIONING www.tradeplumbing.co.uk Call Sales On 08708034288 Check for obvious signs of damage to the cylinder and controls, and also that the controls fitted correspond with the references quoted in these instructions. Ensure that the Drain Cock at the base of the appliance is closed before commencing.
www.tradeplumbing.co.uk Call Sales On 08708034288 MAINTENANCE CORROSION YSTEM HERMAL MMERSION EATER NVENTED ONTROLS www.tradeplumbing.co.uk Call Sales On 08708034288 To ensure efficient safe operation, it is recommended that the appliance is serviced annually by a competent person. After servicing, preliminary electrical system checks must be carried out to ensure electrical safety (i.e.
www.tradeplumbing.co.uk Call Sales On 08708034288 HERMOSTATS AINTENANCE www.tradeplumbing.co.uk Call Sales On 08708034288 4) Expansion relief valve - check manually by turning the test knob (ensure valve closes after testing); 5) Discharge pipes (D1) - from both temperature & pressure relief and expansion relief valve for obstructions;...
www.tradeplumbing.co.uk Call Sales On 08708034288 www.tradeplumbing.co.uk Call Sales On 08708034288 Unvented Controls(s) Check controls as per the following: 1) Line strainer - with the water supply turned off remove screen from strainer and clean of any detritus; 2) Expansion vessel - with the water supply turned off and taps open, check expansion vessel pressure and top up as necessary;...
www.tradeplumbing.co.uk Call Sales On 08708034288 FAULT FINDING FAULT NO HOT WATER FLOW REDUCED FLOW RATE WATER FROM HOT TAPS IS COLD DISCHARGE FROM PRESSURE/ TEMPERATURE RELIEF VALVE DISCHARGE FROM EXPANSION VALVE www.tradeplumbing.co.uk Call Sales On 08708034288 POSSIBLE CAUSES REMEDY 1) Mains cold water Check and open Isolating supply shut off and/or stop valve.
Need help?
Do you have a question about the Unvented Hot Water Storage Cylinders and is the answer not in the manual?
Questions and answers