Siemens CCWC1335-LP Instruction Manual
Siemens CCWC1335-LP Instruction Manual

Siemens CCWC1335-LP Instruction Manual

1/3 inch high-res extended dynamic day/night camera

Advertisement

1/3 inch High-Res Extended
Dynamic Day/Night Camera
CCWC1335-LP
CCWC1335-MP
Instruction Manual
Fire Safety & Security Products
Siemens Building Technologies

Advertisement

Table of Contents
loading

Summary of Contents for Siemens CCWC1335-LP

  • Page 1 1/3 inch High-Res Extended Dynamic Day/Night Camera CCWC1335-LP CCWC1335-MP Instruction Manual Fire Safety & Security Products Siemens Building Technologies...
  • Page 2 Dear Customer By selecting this SIEMENS product, you have chosen a professional device that guarantees the highest possible quality and reliability. We would like to thank you...
  • Page 3: Table Of Contents

    ALARM FUNC..................24 7.2.16.4 ALARM OUT ..................24 7.2.16.5 ALARM DELAY ..................24 7.2.16.6 ALARM TEXT..................24 7.2.16.7 CHROMA ....................24 7.2.16.8 CAMERA TEXT..................24 7.2.17 REMOTE....................25 7.2.17.1 MODEL ....................25 7.2.17.2 ADDRESS....................25 7.2.17.3 BAUD RATE...................25 7.2.17.4 PROTOCOL ...................26 Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 4 7.2.17.5 SOFT VER .....................26 7.2.17.6 Pattern....................26 7.2.18 NEXT/ BACK ...................26 7.2.19 EXIT ......................26 7.2.20 CANCEL....................26 7.2.21 DEFAULT ....................26 Index .......................27 Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 5: General Information

    To ensure normal operation and to avoid EMC problems, the product must be installed according to the currently valid EMC installation guidelines. To meet the CE norms, enclosed EMI-cores should be applied to the Y/C and power cable (see chapter 7.1). Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 6: Manufacturer's Declaration Of Conformity

    EN 55022:1998 Class B EN 50130-4:1998 EN 61000-3-2 A2: 1998 EN 61000-3-3: 1995 The EU certificate of conformity is available for official inspection and is held at: Siemens Building Technologies SBT FSP DE Siemensallee 84 76187 Karlsruhe, Germany Ordering Data Designation Order No.
  • Page 7 Package contents Quickstart manual Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 8: General Guidelines

    This is a fixed pattern, which may appear over the entire monitor screen when the camera is operated at a high temperature. Jagged picture When viewing stripes, straight lines, or similar patterns, the image on the screen may appear jagged. Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 9: Technical Specifications

    Wide dynamic OFF/ON (X 128) Gain control Selectable (OFF, Normal, Turbo); gain (up to 30 dB) Backlight compensation 6 area selectable: Center 1, Center 2,Up Half, Low Half, Middle Low, Middle High Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 10 OSD control 5 control keys on the side-panel of camera Default settings Default setting restored by pushing the DEFAULT button Remote control RS-485 Alarm IN Alarm OUT NC or NO selectable Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 11: Camera Parts & Connections

    Camera Parts Back focus adjustment ring ① Back focus lock screw ② Tripod mount hole ③ IRIS connector ④ Power indicator ⑤ Video output ⑥ Power cord (or power terminal) ⑦ Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 12: Connector Pin Definition

    1. Damp- 2. NC 2. Damp+ 3. VIDEO 3. Drive + 4. GND 4. Drive- Y/ C terminal Y (luminance, 1 Vpp, 75 ) C (chrominance, 0.3 Vpp (burst), 75 ) Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 13: Osd Setting Hierarchy

    Camera Parts & Connections OSD Setting Hierarchy OSD SETTING (P1) (P2) Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 14: Installing The Camera

    Select ENTER on the OSD; the menu will appear on the display and will disappear after 30 seconds if no action occurs. The shaded setting area means an item is selected and it keeps blinking. Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 15: D/N Mode

    When set to this mode, the camera will remain in color mode. MANUAL When set to this mode, the camera will be switched to color or B/W mode manually according to a signal received at a terminal on the rear panel. Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 16: D/N Level

    We recommend using the D/N mode “MANUAL” when the camera is used with discrete IR illumination in order to prevent the continual switching between color and B/W mode that might occur with the D/N mode “AUTO”. Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 17: Exposure

    WD „On“ activates the WD-mode that expands the dynamic range of the camera x128. NOTE: ELC-mode is for usage with fixed iris lenses! When activating WD-mode under extreme light-conditions, the video-output might look “artificial”; but the picture contents are much better visible. Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 18: Shutter

    SENS UP GAIN NORMAL SYNC LL:000 NEXT EXIT CANCEL DEFAULT Fig. 7 GAIN Selection of GAIN: (NORMAL / TURBO / OFF) Move the cursor to the position shown in Fig. 7. Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 19: Sync

    NEXT EXIT CANCEL DEFAULT Fig. 9 This function is for selecting the backlight mode (OFF, BLC1, BLC2, BLC3, BLC4, BLC5, BLC6) Move the cursor to the position shown in Fig. 9. Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 20: White Bal

    R and B (red and blue) values using the UP/ DOWN button. To exit, use the LEFT/ RIGHT to move the cursor between R and B, and press ENTER. Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 21: Gamma

    Move the cursor to the position shown in Fig. 13. Use the LEFT/ RIGHT button to open this menu item, then move the cursor left and right to select the desired zoom factor. The maximum zoom factor is X2.6. Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 22: Mirror

    1 SET CLR BACK CLEAR ALL In the submenu, the user can select ON or OFF for the privacy zone and set up to 8 blocks at any position on the screen. Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 23: Blemish Det

    Press ENTER to perform back focus adjust. This function will force the iris of the AI lens to open fully and set the shutter speed temporarily to AUTO for easy back focus adjustment. Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 24: Alarm Func

    N O P Q R S T U V W X Y Z 0 1 2 3 4 5 6 7 8 9 : < > □ - . , ; x / BACK CLEAR Fig. 19 CAMERA TEXT Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 25: Remote

    The camera address must be set correctly before installing the camera. Otherwise remote access may not be possible. 7.2.17.3 BAUD RATE This function is used to set the camera’s remote baud rate in the range from 2400 to 19200 bits per second. Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 26: Protocol

    Select one of the 3 various protocols, depending on the type of remote connectivity, for remote OSD control camera setup: SIEMENS-B: When using the camera with bi-directional remote control under remote software and PC (remote software provides full parameter setup).
  • Page 27: Index

    DEFAULT 24 Dimensions 8 REMOTE 23 EU Directive 6 Safety precaution 5 EXIT 24 SHUTTER 16 EXPOSURE 15 SYNC 17 Function setting 13 Transportation 7 GAIN 16 WHITE BAL 18 GAMMA 19 Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 28 Issued by © 2005 Copyright by Siemens Building Technologies Siemens Building Technologies AG Fire & Security Products GmbH & Co. oHG Data and design subject to change without notice. D-76181 Karlsruhe Supply subject to availability. Printed in the Federal Republic of Germany www.sbt.siemens.com/fsp...

This manual is also suitable for:

Ccwc1335-mp

Table of Contents