Half Opto Cable From Mvs-8500 Series To Opto I/O Module - Cognex MVS-8000 Series Hardware Manual

Frame grabber
Hide thumbs Also See for MVS-8000 Series:
Table of Contents

Advertisement

2
Half Opto Cable from MVS-8500 Series to Opto I/O
Module
Cognex cable 300-0399 connects eight of the MVS-8500 series I/O lines to the
opto-isolated I/O module, and brings the other eight lines out to a Phoenix 10-pin
terminal strip. The MDR20 connector connects to the frame grabber; the DB-26M
connects to the opto-isolated I/O module. Figure 30 depicts the cable.
terminal
Figure 30. Cable 300-0399
This cable allows you to connect trigger lines directly, without incurring the small delay
added by opto-isolation, but at the same time, to take advantage of opto-isolation for
strobe lines. This cable provides:
MVS-8500 Series Hardware Manual
DB-26 M
10-pin
strip
Four general use opto-isolated input lines
Four opto-isolated output lines that can be configured as strobe lines
Four bidirectional TTL lines that can be configured as trigger lines
Four general use bidirectional TTL lines
MVS-8500 Series Hardware
MDR20