    For QR015 (D in Fig. 1) is 711 mm - 813 mm (28 in. - 32 in.). For QR060, (D in Fig. 1) is 458 mm - 813 mm (18 in. - 32 in.).
  • Page 4: Warranty

    Warranty ONE YEAR LIMITED WARRANTY A thorough inspection must be made before installation and any damage must be promptly reported. We will not be liable for failures or damage that could have been discovered or avoided by proper inspection and testing prior to installation . Conglom Kitchen &...
  • Page 5: Pre-Installation

    Safety gloves HARDWARE INCLUDED NOTE: Hardware not shown to actual size . Model Part Description Quantity QR015 Long tapping screw - (M5 mm x 30 mm) Model Part Description Quantity Long tapping screw - (M5 mm x 12 mm) QR060 Screw - (M4 mm x 16 mm) CONGLOMKB.COM...
  • Page 6: Package Contents

    Pre-Installation (continued) PACKAGE CONTENTS Model Part Description Quantity QR015 Range Hood Model Part Description Quantity Range Hood QR060 Duct Set...
  • Page 7: Planning Installation

    - The distance (1) from the cooking surface to the range hood must be at least 18 in. (458 mm) for QR060, for QR015 the minimum distance is 28 in . (711 mm) . For the best performance, do not install the range hood more than 32 in .
  • Page 8 Pre-Installation (continued) Follow these guidelines when installing duct work: - Your venting system must vent to the outdoors either horizontally through the back wall (13) or vertically through the roof (14) (refer to Fig . 4/Fig . 5) . - Use round metal duct work with a uniform diameter of 6 in . (152 mm) . The total duct run in the venting system should be not more than 10.7 m (35 ft).
  • Page 9 Pre-Installation (continued) QR015: Size of the hole to be cut on the bottom of the cabinet . 24 3/8” (620 mm) Fig.6 Size of motor housing that needs to be inside the cabinet . Fig.7 CONGLOMKB.COM Please contact 1-877-333-0098 for further assistance.
  • Page 10 Pre-Installation (continued) QR060: Size of the hole to be cut on the bottom of the cabinet . 15” (380mm) Fig. 8 Size of motor housing that needs to be inside the cabinet . Fig. 9...
  • Page 11: Installation

    Pre-Installation (continued) WIRING CONNECTION REQUIREMENTS Risk of electrical shock . This range hood DANGER: must be properly grounded . Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. DANGER: Turn off the power circuit breaker or the power switch on the junction box before installing this OBSERVE ALL GOVERNING CODES AND ORDINANCES WARNINGS...
  • Page 12 Installation For QR015: Installing the Damper (If Necessary) CAUTION: Be very careful when installing the damper . Applying too much force or not bending the damper enough may damage or break the damper hinge ends . The damper is pre-installed at the factory. Make sure that it has not come loose during shipping and re-install it, if necessary.
  • Page 13 Installation For QR060: Installing the Duct Set WARNING: This unit has sharp edges . Always wear safety gloves during installation. - Attach the duct set (C) to the range hood (B) with eight screws (BB) . Installing the Damper (If Necessary) WARNING: Sharp edges .
  • Page 14 Installation (continued) Installing the Range Hood As per Fig. 8, cut the required hole in the cabinet. - Lift the range hood (A) up under the cabinet to determine its final position. Fix the unit onto the cabinet with 6pcs of M5 x 12 mm tapping screws (AA).
  • Page 15: Operation

    Operation Push button NOTICE: The fan and lights operate independently of each other . Turning ON/OFF the unit Turning ON/OFF the lights - To turn on the fan, press the appropriate speed control - Press the light switch (5) to turn on and off the lights . switch [Low Speed (2), Medium Speed (3), High Speed (4)] to select the desired level of power .
  • Page 16 Operation There are four buttons, ON/OFF, SPEED, LIGHT and CLOCK SETUP. The center screen will show the clock (12 hour) . Turning ON/OFF the unit Delay shut off function - Press (5) to turn on the power . - While the fan is working, press (5) once, the fan and lights When you turn the power on, the unit starts working in high will automatically turn off after 2 minutes .
  • Page 17: Maintenance

    Maintenance FILTERS / BAFFLE NETS DANGER: Turn off the power circuit breaker or the power switch on the junction box before performing maintenance. When filters / baffle nets need replacing, exchange them with Touching circuitry inside the range hood while it is similar filters / baffle nets with stainless steel clips.
  • Page 18: Care And Cleaning

    Care and Cleaning RANGE HOOD WARNING: Failure to maintain basic standards of care and cleaning of the range hood will increase the risk of fire. The range hood should be cleaned (regularly internally and externally) to preserve its appearance and performance. Do Not: - Always clean in the direction of the grain (original - Do not use corrosive or abrasive detergents, steel...
  • Page 19: Troubleshooting

    Troubleshooting DANGER: Turn off the power circuit breaker or the power switch on the junction box before performing maintenance . Touching circuitry inside the range hood while it is energized will result in death or serious injury . Problem Solution The range hood will not operate .
  • Page 20: Specifications

    Illumination Venting Options 29.9 in. (760 mm) W High 120 V / 500 ± 2 x Max. 20 W / 12 V, QR015 12 in. (305 mm) D Medium 60 Hz / Push Button Top venting Type JC 13.8 in. (350 mm) H...
  • Page 21: Service Parts

    If you are missing parts or if you require replacement parts, please call our customer service team at 1-877-333-0098 (8:30 am – 5 pm, EST, Monday– Friday) . Identify the required part(s) and have the part number(s) ready . Part Number Description Picture QR001 QR003 QR006 QR009 QR014 QR015 QR019 QR060 QHR106 Control Switch QHR105...
  • Page 22 Service Parts (continued) Part Number Description Picture QR001 QR003 QR006 QR009 QR014 QR015 QR019 QR060 QHR109 Fan (93mm / 3-5/8in) QHR111 Fan Set QHR107 QHR110 Fan Guard QHR115 Aluminum Filter (370 mm x 320 mm) QHR114 Aluminum Filter (366 mm x 344 mm)
  • Page 23 Imported by: St-Laurent, Québec, H4S 2C3 1-877-333-0098 www.conglomkb.com Made in China Retain this manual for future use.

This manual is also suitable for:

Qr060Qr001Qr006Qr003Qr014Qr009 ... Show all

Table of Contents