Page 1
IDEALARC CV-305 For use with machine Code Numbers 11177, 11178 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operation on your part.
351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199. BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE PERFORMED ONLY BY QUALIFIED INDIVIDUALS.
ELECTRIC SHOCK can kill. 3.a. The electrode and work (or ground) circuits are electrically “hot” when the welder is on. Do not touch these “hot” parts with your bare skin or wet clothing. Wear dry, hole-free gloves to insulate hands.
Page 4
WELDING SPARKS can cause fire or explosion. 6.a. Remove fire hazards from the welding area. If this is not possible, cover them to prevent the welding sparks from starting a fire. Remember that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas.
Page 5
PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instruc- tions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suivantes: Sûreté Pour Soudage A L’Arc 1. Protegez-vous contre la secousse électrique: a.
Page 6
The code number is especially important when identifying the correct replacement parts. - Register your machine with Lincoln Electric either via fax or over the Internet. • For faxing: Complete the form on the back of the warranty statement included in the literature packet accompanying this machine and fax the form per the instructions printed on it.
• Do not touch electrically hot parts. • Always connect the Idealarc CV-305 grounding terminal (located on the welder base near the reconnect panel) to a good electrical earth ground.
FIELD INSTALLED OPTIONS For installation of compatible field installed options (see the ACCESSORIES section of this manual and refer to the instructions included with those options. REQUIRED EQUIPMENT-CONTROL CABLE CONNECTIONS Follow the instructions below which are appropriate for the wire feeder that will be used. LF-72 to CV-305 a) Turn the CV-305 Power switch to the "OFF"...
PARALLELING The CV-305 is not designed to be paralleled with itself or any other power source. CONNECTION OF AUXILIARY EQUIPMENT TO THE WIRE FEEDER RECEPTACLE Occasionally, it may be necessary to make connection to the circuits present in the 14-pin wire feeder recep- tacle.
OPERATING INSTRUCTIONS Read and understand this entire section before oper- ating the machine. GENERAL WARNINGS SAFETY PRECAUTIONS Observe additional Safety Guidelines detailed throughout this manual. OPERATION WARNING ELECTRIC SHOCK can kill. • Do not touch electrically live parts or electrode with skin or wet clothing.
GRAPHIC SYMBOLS THAT APPEAR ON THIS MACHINE OR IN THIS MANUAL POWER REMOTE OUTPUT VOLTAGE CONTROL WARNING OPERATION INDICATES WARNING INFORMATION LOCATED ON RIGHT CASE SIDE CV-305 THERMAL PROTECTION INDICATOR LIGHT CIRCUIT BREAKER CLOCKWISE ROTATION INCREASES VOLTAGE LOCAL OUTPUT VOLTAGE CONTROL...
CAUTION When using a CV-305 power source with wire feed- ers, there will be a small spark if the electrode con- tacts the work or ground within several seconds after releasing the trigger. When used with some wire feeders with the electrical trigger interlock in the ON position, the arc might restart if the electrode touches the work or ground during these several seconds.
CONTROLS AND OUTPUT SETTINGS All operator controls and adjustments are located on the case front of the CV-305. Refer to Figures B.1. FIGURE B.1 - CONTROL AND OUTPUT PANEL 1. POWER SWITCH A two-position toggle switch.Controls the input power to the CV-305. 2.
Page 16
9. WIRE FEEDER VOLTMETER SWITCH This switch selects the polarity of the wire feeder voltmeter, if so equipped. When welding electrode positive (MIG, Outershield and some Innershield processes) set the switch to "+". When welding electrode negative (most Innershield electrodes) set the switch to "-". This switch has no effect on the welding polarity.
CV-305 auxiliary power for that equip- ment. ___________________________________________ OVERLOAD PROTECTION This welder has thermostatic protection from exces- sive duty cycles, overloads, loss of cooling, and high ambient temperatures. When the welder is subjected to an overload or loss of cooling, a thermostat will open.
FACTORY INSTALLED OPTIONS/ACCESSORIES There are no factory installed options/accessories on the CV-305. FIELD INSTALLED OPTIONS REMOTE VOLTAGE CONTROL (K857) The K857 consists of a control box with 25 feet (7.6 m) of four conductor cable. Installation of a K857 Remote Voltage Control in the CV-305 requires a K864 Remote Control Adapter.
1. The fan motor has sealed bearings which require no service. 2. In extremely dusty locations, dirt may clog the air channels causing the welder to run hot with prema- ture tripping of thermal protection. Blow out the welder with low pressure air at regular intervals to eliminate excessive dirt and dust build-up on inter- nal parts.
HOW TO USE TROUBLESHOOTING GUIDE Service and Repair should only be performed by Lincoln Electric Factory Trained Personnel. Unauthorized repairs performed on this equipment may result in danger to the technician and machine operator and will invalidate your factory warranty. For your safety and to avoid Electrical Shock, please observe all safety notes and precautions detailed throughout this manual.
Observe all Safety Guidelines detailed throughout this manual BUILT-IN DIAGNOSTIC ROUTINES AND ERROR CODES The CV-305 Meter PC Board displays error codes when certain trouble conditions exist. The error codes, trouble conditions, and possible remedies are listed below. ERROR TROUBLE CODE 1.
Observe all Safety Guidelines detailed throughout this manual MACHINE TROUBLESHOOTING GUIDE Not all trouble conditions can be recognized by the PC board, and displayed as error codes. The following guide covers most other trouble conditions. PROBLEMS (SYMPTOMS) Machine has no output. Machine has minimum output and no control.
Page 23
Observe all Safety Guidelines detailed throughout this manual PROBLEMS (SYMPTOMS) Thermal Protection Indicator light is Machine does not have maximum output Machine will not shut off. Variable or sluggish welding arc. Digital meters do not light - or - Digital meter display is incorrect. If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
Page 24
Observe all Safety Guidelines detailed throughout this manual PROBLEMS (SYMPTOMS) Output Control not functioning on the machine. Poor arc striking with semiautomatic wire feeders. Poor arc characteristics If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
Observe all Safety Guidelines detailed throughout this manual OPTIONS TROUBLESHOOTING GUIDE K857 (or other) Remote Output Control PROBLEMS (SYMPTOMS) Output control not functioning on Remote Control. Output Control not functioning on the machine. If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
If there is damage to the PC board or if replacing PC board corrects problem, return it to the local Lincoln Electric Field Service Shop. If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
OUTPUT VOLTAGE The open circuit voltage of the machine should be 10 to 43 volts. If any other condition exists, refer to the Troubleshooting Guide. FAULT PROTECTION OPERATION The overload protection circuit on the PC Board will cause the CV-305 meter to display "E60". This pro- tection circuit will reset itself automatically.
Page 36
TWIST-MATE CABLE PLUG INSTALLATION INSTRUCTIONS TWIST-MATE WELDING CABLE PLUG INSTALLATION INSTRUCTIONS TURN THE POWER SWITCH OF THE WELDING POWER SOURCE "OFF" BEFORE INSTALLING PLUGS ON CABLES OR WHEN CONNECTING OR DISCONNECTING PLUGS TO WELDING POWER SOURCE. CHECK THAT THE CONNECTOR BOOT IS MARKED FOR THE APPROPRIATE CABLE SIZE PER TABLE BELOW;...
Page 39
● WARNING ● Spanish ● AVISO DE PRECAUCION ● French ● ATTENTION ● ● German WARNUNG ● Portuguese ● ATENÇÃO ● Japanese Chinese Korean Arabic ● ● ● ● ● ● ● ● ● ●...
Page 40
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Spanish ● PRECAUCION French ● ATTENTION ● German WARNUNG Portuguese ● ● Japanese Chinese Korean Arabic WARNING AVISO DE ATENÇÃO...
Page 41
• World's Leader in Welding and Cutting Products • • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com...
Need help?
Do you have a question about the IDEALARC CV-305 and is the answer not in the manual?
Questions and answers