CARE AND CLEANING

1) Unplug from the wall outlet.
2) Clean the Induction Cooktop and the Control Panel with a damp cloth.
NOTE:
• Do not use a brush or abrasive cleansers. This may damage the
Cooktop.
• Do not immerse the unit in water or any other liquid.
3) Dry with a soft cloth.
4) Clean the unit after each use.
All servicing, other than cleaning, should be performed by an authorized
service representative. See Warranty section.

ERROR CODES:

Error Code
(See Digital
Display)
E0, E2, E5, E6
& E7
E1
E3
E4
Reason
Internal Circuit Error
- parts are either
overheating or have an
open or short circuit
Cookware Sensor
Detection
Incorrect Voltage Sensor
– Voltage over 150V
Incorrect Voltage Sensor
– Voltage below 80V
Solution(s)
• Contact Salton service
center. See 'Warranty'
section in this instruction
booklet for contact
information
• Check whether or not
cookware is suitable.
• Make sure the cookware
is within the circular
cookware placement
guides indicated on the
Induction Cooktop.
• Cookware was removed
during cooking. Replace
cookware back on
Cooktop.
• Make sure the outlet used
is 110/120V AC.
• Make sure the outlet used
is 110/120V AC.