Page 3
The 'Caution' label indicates that severe personal injury or equipment damage may occur if instructions are not followed carefully. This Hyundai generator will meet your requirements if you operate it properly according to this manual. If the instructions in this manual are not followed carefully personal injury, equipment damage or death may occur.
Page 4
1. To prevent fire Never add fuel to the fuel tank whilst the engine is running. Wipe away any spilt fuel or oil with a clean cloth before operating. Keep explosives and any other flammable products away from the machine at all times. -To prevent fire and to provide adequate ventilation, keep the generator at least one metre away from buildings and other equipment during operation.
Page 5
- Most electric motors require up to 3 times the rated wattage to start - Do not exceed the specified current limit of any socket. - Do not connect the generator to a household circuit of a house or building unless it is through a mains/generator changeover switch...
Contents 1. Main Technical Specifications and Data............. 2. Configuration...................... 3. Preparation for Starting ................... 4. Starting the Generator..................5. Operating the Generator..................6. Load........................7. Stopping the Generator..................8. Periodic Checks and Service................9. Long-term Storage....................10. Troubleshooting and Remedy................11.
1. MAIN TECHNICAL SPECIFICATIONS AND DATA Model DHY6000SE/LR DHY6000SE/LR-3 Rated Frequency (Hz) Max. Power (KW/kVA) 5.2/6.25 6.25 Voltage (AC) (V) 115/230 230/400 Max. Current (AC) (V) 45.2/22.6 7.5/9.0 Engine speed (r/min) 3000 3000 Generator Power Factor (cosθ) Alternator Single bearing AVR alternator DC Output 12v/8.3A...
Page 8
3. PREPERATION FOR STARTING 3.1 Selection and Handling of the fuel Selection of fuel Only use standard specification diesel, this can be red or white Keep dust and water out of the fuel When filling the fuel tank from drums, make sure that no dust or water is mixed in with the fuel.
Page 9
helps prevents damage such as bearing seizures etc. However, this should not be relied upon and the engine oil level should be checked and topped up if required, daily. To ensure the generator maintains a top quality performance and the life of the generator is as long as possible, it is important to use the correct engine oil - SAE15w40 diesel engine oil and change after the first 20 hours, then every 100 hours.
Page 10
- Before starting the engine, be sure to switch OFF any appliances connected to it. - Ensure that the breaker switch is OFF before switching between 115v/230v. 3.5 How to open the cabinet door and covers of this Hyundai generator 1. Open the cabinet door for daily inspection. Turn the lever counter clockwise and raise the door.
4. STARTING THE GENERATOR Do not connect tools or any other appliances to the generator before starting. 1. Starting 1. Open the fuel cock. 2. Set the engine speed lever to the 'RUN' position. 3. Turn the starting key clockwise to the 'START' position. Remove your hand from the key as soon as the engine starts.
- Always leave the starting key in the 'ON' position while the engine is running. 2. Battery 1. When you first install the battery, ensure that the battery's polarity is the same as the generator's battery leads - Black = negative, Red = positive. Check the voltage is 12.3V+, if lower, the battery must be charged.
- Do not loosen or readjust either the engine speed limiting bolt or the fuel injection limiting bolt as this will cause the performance of the generator to be affected. 5.2 Checks during the running of the generator 1. Check that there is no abnormal sound or vibration. 2.
- Connect the positive and negative charging lead clips to the correct poles of the battery. - If you try to charge a large capacity battery, which is at a low voltage, excessive current flow may occur. This may result in the fuse for the 12v DC blowing. - Do not use 12V DC and 230V AC at the same time.
3. Run the generator without load for three minutes. Do not stop the engine suddenly or whilst under load. This can damage the AVR and cause damage to the alternator through overheating. - Turn the electric key start switch to the 'OFF' position, or Press down the stop lever. - Turn the fuel cock lever to the 'S' position - Do not stop the engine with the decompression lever.
Page 16
Every First Three Six Months Every Item Month Months or 500 hours Year or or 20 or 100 1000 hours hours hours Check and refill with diesel Change engine oil Check and refill engine oil Check for oil leakage Check and tighten fastening parts Yes - Replace engine oil first...
Page 17
- Never run the engine without the air filter element or with a damaged element. 8.4 Clean and replace fuel filter The fuel filter should be replaced regularly to ensure maximum engine output. Replace Every 6 months or 500 hours or sooner if contaminated with dirt or water 1.
negative). Check the voltage is above 12.3V, if not the battery should be charged. 2. Check the voltage, once a month. The voltage of a standard battery is 12.5v- 13.6v. 3. If the battery voltage is too low, it should be removed and re-charged. 4.
10. TROUBLESHOOTING AND REMEDY Problem Fault Cause Remedy The diesel engine will not Insufficient fuel Refill with fuel start Fuel tap is not at ON position Turn it to the 'ON' position Fuel injection pump does not Remove the injector pump deliver the fuel or deliver and have tested.
2006/95/EC Low Voltage Directive 2000/14/EC Noise Emissions Directive Warranty This Hyundai generator is covered by a 12 month/1000 hour Warranty. The warranty covers manufacturing defects only, not wear and tear. The following are not covered under warranty: Damage caused by improper use, dropping, wrongly adjusting, or failing to follow the operating and service requirements, e.g lack of lubrication...
Need help?
Do you have a question about the DHY6000SE/LR and is the answer not in the manual?
Questions and answers