Bosch GWH 715 ES Applications Manual

Tankless and point-of-use water heaters
Hide thumbs Also See for GWH 715 ES:

Advertisement

Applications manual
For tankless and point-of-use water heaters

Advertisement

Table of Contents
loading

Summary of Contents for Bosch GWH 715 ES

  • Page 1 Applications manual For tankless and point-of-use water heaters...
  • Page 2 Applications manual BOSCH THERMOTECHNOLOGY CORPORATION Application manual | 11.2007...
  • Page 3: Table Of Contents

    2.1 Sizing tankless water heaters 2.2 Bosch GWH 715 ES 2.3 Bosch GWH C 800 ES 2.4 Outdoor Installation for GWH 715 ES and GWH C 800 ES 2.5 Bosch GWH 345 ESR 2.6 Bosch GWH 450 ESR 2.7 Bosch GWH 425 EF 2.8 Bosch GWH 425 HN...
  • Page 4: Introduction

    Applications manual 1 Introduction The Bosch Applications Manual is intended to present some of the most common applications of the Bosch line of tankless and point of Rule of thumb sizing use water heaters. Application drawings are shown with both piping The tables below provide a general rule of thumb when sizing for and corresponding electrical schematics where applicable.
  • Page 5 Applications manual GWH C 800 ES GWH C 8 GWH 715 ES GWH 425 PN/HN/EF GWH 425 GWH 260 PN/HN Degree rise (°F) Gas Appliance Sizing Chart RP27PT RP17PT RP17PT RP12PT RP12PT RP7P RP3P RP1P RP9P Degree rise (°F) Electric Appliance Sizing Chart...
  • Page 6: Bosch Gwh 715 Es

    Computerized temperature control — ensures temperature stability Floor (C) 12" Model GWH 715 ES N for natural gas (NG) supply Model GWH 715 ES L for liquid propane (LP) supply 15-year warranty on heat exchanger GWH 715 ES Technical Specifi cations...
  • Page 7: Bosch Gwh C 800 Es

    Applications manual 2.3 Bosch GWH C 800 ES Features: Electronic ignition and built in power vent GWH C 800 ES Installation Clearances Condensing technology with 92% thermal effi ciency Top (A) 12" Vents vertically or horizontally with 3" or 4" PVC, CPVC or ABS Front (B) 1"...
  • Page 8: Outdoor Installation For Gwh 715 Es And Gwh C 800 Es

    Applications manual 2.4 Outdoor Installation for GWH 715 ES, Installation on wood siding and GWH C 800 ES Outdoor Kit (PTOK) installation: The installation of this outdoor kit (PTOK) is required when installing either of the above appliances outdoors Outdoor cap easily retrofi ts to these indoor models...
  • Page 9: Bosch Gwh 345 Esr

    Applications manual 2.6 Bosch GWH 345 ESR Features: Specifi cally designed for recirculating applications Electronic ignition and built in power vent GWH 345 ESR thermal effi ciency of 82% Vents vertically or horizontally with 3" stainless steel (AL29-4C) Direct vent room-sealed combustion Computerized temperature control —...
  • Page 10: Bosch Gwh 450 Esr

    1 0 | Applications manual 2.6 Bosch GWH 450 ESR Features: Specifi cally designed for recirculating applications Electronic ignition and built in power vent GWH 450 ESR thermal effi ciency of 81% Vents vertically or horizontally with 3" stainless steel (AL29-4C) Direct vent room-sealed combustion Computerized temperature control —...
  • Page 11: Bosch Gwh 425 Ef

    Applications manual | 11 2.7 Bosch GWH 425 EF Features: Electronic ignition and built in power vent Thermal effi ciency of 82% Vents with 4" stainless steel or galvanized vent pipe Specifically designed for horizontal vent terminations Modulating gas valve — ensures temperature...
  • Page 12: Bosch Gwh 425 Hn

    1 2 | Applications manual 2.8 Bosch GWH 425 HN GWH 425 HN Installation Clearances Features: Top (A) 12" Hydro-generated ignition Front (B) 4" 80% thermal effi ciency Endless hot water for one major application at a time Back 0"...
  • Page 13: Bosch Gwh 425 Pn

    Applications manual | 13 2.9 Bosch GWH 425 PN GWH 425 PN Installation Clearances Features: Top (A) 12" Standing pilot ignition Front (B) 4" 78% thermal effi ciency Endless hot water for one major application at a time Back 0"...
  • Page 14: Bosch Gwh 260 Pn

    1 4 | Applications manual 2.10 Bosch GWH 260 PN GWH 260 PN Installation Clearances Features: Top (A) 12" Standing pilot ignition Front (B) 4" 78% thermal effi ciency Mounts on wall for easy installation Back 0" Venting: 4" double wall B-vent — natural draft Sides 4"...
  • Page 15: Powerstream Pro Rp17Pt, Rp27Pt

    2.3 gpm 3.7 gpm 60°F Rise 2.0 gpm 3.0 gpm 70°F Rise 1.7 gpm 2.6 gpm 80°F Rise 1.5 gpm 2.2 gpm 3 independent 40 amp double-pole circuit breakers Fig. 6 RP27PT Electrical Connections BOSCH THERMOTECHNOLOGY CORPORATION Applications manual | 11.2007...
  • Page 16: Powerstream Pro Rp1P, Rp2P, Rp3P, Rp7P, Rp9P, Rp12Pt

    3.60 — 32° 24° 16° 12° RP9P 8AWG 9.50 — — 84° 64° 42° 32° 0.75 — 4.75 — 42° 32° 21° 16° RP12PT 6AWG 12.00 — — 90° 72° 52° 42° 0.75 BOSCH THERMOTECHNOLOGY CORPORATION Application manual | 11.2007...
  • Page 17: Ariston Pro Gl2.5Ti, Gl4Ti, Gl8Ti

    Recovery at 90° rise 7 gph 7 gph 7gph Temperature range 65-145°F 65-145°F 65-145°F Water connections ½" NPT ½" NPT ¾" NPT Maximum water 150 PSI 150 PSI 150 PSI pressure Relief valve Installed Installed Included BOSCH THERMOTECHNOLOGY CORPORATION Applications manual | 11.2007...
  • Page 18: Domestic Water Heating Applications

    Applications manual 3 Domestic Water Heating Applications Potable water Potable water is water that is suitable for drinking. Bosch Water Heating appliances are approved to heat potable water only. Heating any other liquid other than potable water will void the manufactures warranty covering the appliance.
  • Page 19: Temperature And Pressure Relief Valve

    Additional safety and/or auxiliary equipment may be needed. This diagram is for reference use by officials, designers and licensed installers. It is expected that installers have adequate knowledge of accepted industry practices for the equipment, procedures, and applications involved. Drawing is not to scale. Drawing # POU1 rev 06/06 BOSCH THERMOTECHNOLOGY CORPORATION Applications manual | 11.2007...
  • Page 20 Additional safety and/or auxiliary equipment may be needed. This diagram is for reference use by officials, designers and licensed installers. It is expected that installers have adequate knowledge of accepted industry practices for the equipment, procedures, and applications involved. Drawing is not to scale. Drawing # POU2 rev 06/07 BOSCH THERMOTECHNOLOGY CORPORATION Application manual | 11.2007...
  • Page 21 Applications manual | 21 3.1.3 Bosch GWH 260 PN gas tankless water heater The Bosch GWH 260 PN gas tankless water heater offers a compact and lightweight design for easy installation. This unit is equipped with standing pilot ignition and is intended for low volume applications.
  • Page 22: Whole House Applications

    Whole house applications cover the typical home applications up to a 2 or 3 bedroom house. See the sizing guide (Section 2.1) to determine the best Bosch water heater model for your application. An enhanced design including an Ariston mini tank in line to the hot water source will reduce the wait time for hot water and improve temperature stability.
  • Page 23 Additional safety and/or auxiliary equipment may be needed. This diagram is for reference use by officials, designers and licensed installers. It is expected that installers have adequate knowledge of accepted industry practices for the equipment, procedures, and applications involved. Drawing is not to scale. Drawing # WH1R rev 06/07 BOSCH THERMOTECHNOLOGY CORPORATION Applications manual | 11.2007...
  • Page 24 Applications manual 3.2.3 Bosch ProTankless gas water heater Below are two examples of Bosch ProTankless gas water heater installations for the whole house. One example shows an Ariston mini tank in line for reduced hot water wait time and increased temperature stability.
  • Page 25 Applications manual | 25 3.2.4 Bosch ProTankless gas water heater with domestic recirculation loop The circulator should be controlled by an external aquastat, or with a timer to run only during times of expected hot water usage. Cold Bosch GWH 715 ES,...
  • Page 26: High Volume Potable Water Heating

    4 High Volume Potable Water Heating Potable water Potable water is water that is suitable for drinking. Bosch Water Heating appliances are approved to heat potable water only. Heating any other liquid other than potable water will void the manfuctures warranty covering the appliance.
  • Page 27: Pressure Relief

    4.1.1 Bosch ProTankless gas water heater in parallel for commercial applications Two Bosch ProTankless units will have double the activation rate of a single unit. When sizing gas line, ensure the gas line is sized to carry the BTU load of two units plus any additional gas appliances. See the installation manuals for a gas line sizing chart.
  • Page 28: Cascading Unit Applications

    4.2 Cascading unit applications A cascading application should be considered if the potential hot water demand exceeds the capacity of one GWH 715 ES or GWH C 800 ES. The cascading set up supports variable fl ow inputs and is designed for large homes and commercial applications.
  • Page 29: External Storage Tank Loading Applications

    0 feet of head 0 GPM 1 GPM 2 GPM 3 GPM 4 GPM 5 GPM 6 GPM water flow rate Pressure drop curves Note : Flow above 6 GPM is not permitted. BOSCH THERMOTECHNOLOGY CORPORATION Applications manual | 11.2007...
  • Page 30 3 0 | Applications manual 4.3.2 Single unit tank loading application plumbing diagram The GWH 345/450 ESR is specifi cally designed for this application. Cold water feed Bosch GWH 345 ESR, Bosch GWH 450 ESR Symbols Potable water External Pressure...
  • Page 31 Additional safety and/or auxiliary equipment may be needed. This diagram is for reference use by officials, designers and licensed installers. It is expected that installers have adequate knowledge of accepted industry practices for the equipment, procedures, and applications involved. Drawing is not to scale. Drawing # ESTL revA 10/07 BOSCH THERMOTECHNOLOGY CORPORATION Applications manual | 11.2007...
  • Page 32: Open Loop Space Heating

    Some jurisdictions may not allow these types of applications. 5.1.1 Radiant space heating and DHW plumbing diagram Bosch GWH 345 ESR, Bosch GWH 450 ESR Cold water feed...
  • Page 33 Additional safety and/or auxiliary equipment may be needed. This diagram is for reference use by officials, designers and licensed installers. It is expected that installers have adequate knowledge of accepted industry practices for the equipment, procedures, and applications involved. Drawing is not to scale. Drawing # EROL revA 10/07 BOSCH THERMOTECHNOLOGY CORPORATION Applications manual | 11.2007...
  • Page 34 3 4 | Applications manual 5.1.2 Fan coil space heating and DHW plumbing diagram Bosch GWH 345 ESR, Bosch GWH 450 ESR Cold water Fan Coil feed Symbols Potable water Flow Storage expansion tank check tank Fan Coil valve Pressure...
  • Page 35 Additional safety and/or auxiliary equipment may be needed. This diagram is for reference use by officials, designers and licensed installers. It is expected that installers have adequate knowledge of accepted industry practices for the equipment, procedures, and applications involved. Drawing is not to scale. Drawing # EFCOL revA 10/07 BOSCH THERMOTECHNOLOGY CORPORATION Applications manual | 11.2007...
  • Page 36 3 6 | Applications manual 5.1.3 Baseboard/ Radiant Panel space heating and DHW plumbing diagram Bosch GWH 345 ESR, Bosch GWH 450 ESR Cold water feed Symbols Potable water Flow Flow Storage Baseboard/ expansion tank check direction tank Radiant valve...
  • Page 37 Additional safety and/or auxiliary equipment may be needed. This diagram is for reference use by officials, designers and licensed installers. It is expected that installers have adequate knowledge of accepted industry practices for the equipment, procedures, and applications involved. Drawing is not to scale. Drawing # EBBOL revA 10/07 BOSCH THERMOTECHNOLOGY CORPORATION Applications manual | 11.2007...
  • Page 38 3 8 | Applications manual 5.1.4 Baseboard/ Radiant Panel space heating and DHW (with Ariston mini tank) plumbing diagram Bosch GWH 345 ESR, Bosch GWH 450 ESR Cold water feed Aquastat well with 12k ohm thermistor (insulate piping around thermistor)
  • Page 39 Additional safety and/or auxiliary equipment may be needed. This diagram is for reference use by officials, designers and licensed installers. It is expected that installers have adequate knowledge of accepted industry practices for the equipment, procedures, and applications involved. Drawing is not to scale. Drawing # EBBAOL revA 10/07 BOSCH THERMOTECHNOLOGY CORPORATION Applications manual | 11.2007...
  • Page 40 4 0 | Applications manual 5.1.5 Baseboard/ Radiant Panel space heating and DHW (without storage tank) plumbing diagram Bosch GWH 345 ESR, Bosch GWH 450 ESR Cold water feed Insulate piping Symbols Flow Baseboard/ Flow Radiant check direction Piping Panel...
  • Page 41 Additional safety and/or auxiliary equipment may be needed. This diagram is for reference use by officials, designers and licensed installers. It is expected that installers have adequate knowledge of accepted industry practices for the equipment, procedures, and applications involved. Drawing is not to scale. Drawing # BBNTOL revA 10/07 BOSCH THERMOTECHNOLOGY CORPORATION Applications manual | 11.2007...
  • Page 42: Indirect Tank Applications

    Applications manual 5.2 Indirect Tank Applications 5.2.1 Indirect Baseboard/ Radiant Panel space heating and DHW plumbing diagram Note: Not suitable for space heating applications requiring high water temperature. Bosch GWH 345 ESR, Bosch GWH 450 ESR Cold water feed Cold...
  • Page 43 Additional safety and/or auxiliary equipment may be needed. This diagram is for reference use by officials, designers and licensed installers. It is expected that installers have adequate knowledge of accepted industry practices for the equipment, procedures, and applications involved. Drawing is not to scale. Drawing # EID BBOL revA 10/07 BOSCH THERMOTECHNOLOGY CORPORATION Applications manual | 11.2007...
  • Page 44: Maintenance Drawings

    6 Maintenance Drawings Bosch appliances are designed to last for many years. In order to keep the heater operating properly, periodic maintenance is required. Please consult the installation manual for maintenance intervals. A descaling procedure drawing is included to assist in clearing the water heater of mineral deposits that may build up over time.
  • Page 45: Descaling Procedure Diagram

    Applications manual | 45 6.1 Descaling procedure diagram Bosch GWH 715 ES, Bosch GWH C 800 ES, Bosch GWH 425 HN or Bosch GWH 425 PN Symbols Circulating pump Flow direction Filter Service valves Note: This drawing is conceptual in nature and does not purport to address all design, installation or safety considerations.
  • Page 46 4 6 | Applications manual BOSCH THERMOTECHNOLOGY CORPORATION Application manual | 11.2007...
  • Page 47 Applications manual | 47 BOSCH THERMOTECHNOLOGY CORPORATION Applications manual | 11.2007...
  • Page 48 BOSCH THERMOTECHNOLOGY CORPORATION 50 Wentworth Ave Londonderry, NH 03053 Telephone (603) 552-1100 Fax (603) 584-1681 www.boschpro.com INM-APPMAN/ Rev A 01.2008...

Table of Contents