INSTRUCTION MANUAL
ROTATING LASER
Thank you for purchasing the TOPCON RL-H3CL Rotating Laser.
The RL-H3CL instrument has many unique features. For basic operation, rough level the instrument and press power switch. It
will self-level, then emit a rotating laser beam.
For superior product performance, please read these instructions carefully and keep them in a convenient place for future ref-
erence.
GENERAL HANDLING PRECAUTIONS
Before starting work or operation, be sure to check that the instrument is functioning correctly with normal performance.
When storing the instrument for long period, remove the batteries.
Always make sure instrument is dry before putting it in the carrying case. Never store a damp instrument.
DISPLAY FOR SAFE USE
In order to ensure the safe use of this product, prevent any danger to the operator or others, or damage to property, impor-
tant warnings are placed on the product and inserted in the instruction manual. We recommend that you become familiar
with the meaning of these Warnings and Cautions before continuing.
Display
Meaning
Ignoring or disregard of this display may lead
WARNING
to the danger of death or serious injury.
Ignoring or disregard of this display may lead
CAUTION
to personal injury or physical damage.
•Injury refers to hurt, burn, electric shock, etc.
•Physical damage refers to extensive damage to equipment and structure or furnishings.

Exceptions from Responsibility

The user of this product is expected to follow all operating instructions and make periodic checks of the product's performance.
1
The manufacturer, or its representatives, assumes no responsibility for results of a faulty or intentional usage or misuse including any direct, indirect, conse-
2
quential damage, and loss of profits.
The manufacturer, or its representatives, assumes no responsibility for consequential damage, and loss of profits by any disaster, (an earthquake, storms,
3
floods etc.), fire, accident, or an act of a third party and/or a usage in other than usual conditions.
The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits due to a change of data, loss of data, an interruption
4
of business etc., caused by using the product or an unusable product.
The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits caused by usage other than explained in the user
5
manual.
The manufacturer, or its representatives, assumes no responsibility for damage caused by wrong movement, or action due to connecting with other prod-
6
ucts.

Laser Safety

This product uses a visible laser beam, and is manufactured and sold in accordance with "Performance Standards for Light-
Emitting Products" (FDA/BRH 21 CFR 1040) or "Radiation Safety of Laser Products, Equipment Classification, Requirements
and User's Guide" (IEC Publication 60825-1) provided on the safety standards for laser products.
As per the said standard, this product is classified as a "Class ll Laser Product" or "Class 2 Laser Product".
This is a simple product to operate and does not require training from a laser safety officer.
In case of any failure, do not disassemble the instrument. Contact TOPCON or your TOPCON dealer.

NOMENCLATURE AND FUNCTIONS

Manual mode ON (Red LED)
Auto leveling does not function.
Height alert OFF (Red LED)
Height alert does not function.
Height alert OFF switch
OFF:Push twice continuously.
ON:Push once.
Manual mode ON switch
ON:Push twice continuously.
OFF:Push once.
Handle
Height alert function
(Safety lock system)
When auto-leveling and height
alert function are active, after the
laser beam emits for one minute,
this function prevents the instru-
ment from operating if it is dis-
turbed. This insures accurate
control. If the unit is disturbed, all
lamps will blink except battery
power lamp. The elevation (height
of instrument) should be verified
and re-established if necessary.
This function is not active in the
manual mode.

HOW TO OPERATE

1
•Set the instrument to the tripod or smooth surface.
•Make sure instrument is roughly level (±3°).
•Press power switch (ON).
EXAMPLES OF TYPICAL USE
RL-H3CL

SAFETY CAUTIONS

¥ There is a risk of fire, electric shock or physical harm if you attempt to disassemble or
repair the instrument yourself.
This is only to be carried out by TOPCON or an authorized dealer, only !
¥ May ignite explosively.
Never use an instrument near flammable gas, liquid matter, and do not use in a coal mine.
¥ Cause eye injury or blindness.
Do not stare into beam.
¥ Risk of fire or electric shock.
Do not use a wet battery.
¥ Battery can cause explosion or injury.
Do not dispose in fire or heat.
¥The short circuit of a battery can cause a fire.
Do not short circuit battery when storing it.
RL-H3CL
•Press power switch on laser sensor (ON).
2
•Select the precision mode by pressing the On-
Grade precision switch.
•Locate the on-grade position "---" by moving the
laser sensor up and down.
WARNING
Protective glass
Rotary head
Laser beam emits from here.
Battery power (Red LED)
Blinking:
The power is low, but laser is still usable. (Blinking
continues for one minute.)
On Solid:
Dead batteries. Replace the batteries with new
ones. (The lamp is solid for five minutes, then turned
off automatically.)
Auto leveling (Green LED)
Blinking quickly:
Auto leveling is in process.
Blinking slowly:
Auto leveling is almost complete.
On Solid:
Auto leveling is complete.
Power switch
Turn the instrument ON or OFF.
Battery door knob
Battery door
Note
In manual mode
•Auto-leveling function is not active.
•Height alert function is not active.
LS-70B/70C Indicator
High precision mode
When using the Laser
Normal precision mode
Sensor with other
Above grade indicator
select Topcon lasers,
Move the sensor down.
these symbols alert
Audio signal:High pitch, frequent beep
user if laser batteries
are low or if laser has
On-Grade position
been disturbed.
Audio signal:Continuous beep sound
These symbols are
Below grade indicator
not active when used
Move the sensor up.
with RL-H3CL.
Audio signal:Lower pitch, slower frequency
Battery remaining display
Level Vial
Using Laser Sensor On Rod
154
153
152
151
150
149
148
147
146
Laser Sensor
HOLDER−6
131
139
138
137
136
135
134
133
132
131
STANDARD PACKAGE COMPONENTS
Upon opening, make sure that all the followings are included.
1 RL-H3CL Instrument . . . . . . . . . . . . . . . . . . . . . . . . 1set
2 LS-70B/70C* Laser Sensor . . . . . . . . . . . . . . . . . . 1set
3 Size "C" dry batteries (R14PU) . . . . . . . . . . . . . . . . 4pc.
4 9 volt dry battery (6F22/S-006P) . . . . . . . . . . . . . . . 1pc.
5 Carrying case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1pc.
6 Instruction manual. . . . . . . . . . . . . . . . . . . . . . . . . . 1vol.
7 Model-6 Laser Sensor Holder . . . . . . . . . . . . . . . . . 1pc.
* LS-70B is included for some markets instead of LS-70C.
• Use of controls or adjustment or performance of procedures other than those spec-
ified herein may result in hazardous radiation exposure.
• Do not stand or sit on the carrying cases.
It could overturn, causing injury.
• Do not use a damaged instrument case.
It could accidentally open causing damage to the instrument or injury to people.
• Do not place yourself or a reflecting object in the path of the laser beam. If using the
laser outside, avoid positioning it anywhere near eye level to avoid any possibility of
it striking someone in the eye. If this should happen, visibility could be temporarily
impaired, causing disorientation and possible accidental injury.
• Please note that the tips of tripod can be hazardous, be aware of this when setting
up or carrying the tripod.
• Do not allow skin or clothing to come into contact with acid from the batteries, if this
does occur then wash off with copious amounts of water and seek medical advice.
• Do not place instrument on unstable platform, surface or tripod.
If using tripod, make sure instrument is securely attached.
• Risk of injury by falling down a tripod and an instrument.
Always check that the screws of tripod are tightened.
Beam aperture
Beam receiving window
Turn the beam receiving window side
towards RL-H3CL to detect the laser beam.
Indicator
Detect the on-grade position "---" by moving the Laser Sensor
up and down. Directional arrows and audio signals assist in
locating the on-grade position as the laser strikes the beam
On-Grade
receiving window. (Top of Laser Sensor is 40mm (1 9/16")
Index
from on-grade index for offset marking.)
LS-70B:The indicators are located on front and back sides of the
instrument.
LS-70C:The indicator is located only on front side.
On-Grade precision switch
(1 9/16")
Two on-grade precision options are available, normal preci-
sion and high precision. By pressing this switch, the preci-
sion options are switched alternately. Confirm the precision
choice by the indicator. (Normal precision is the default set-
ting each time the sensor is turned on. See LS-70B/70C
Indicator diagram below.)
Power switch
The power switch turns ON or OFF by pressing. If the power
switch is turned ON, all signs will be displayed on the indica-
tor for a second with a beep sound.
Buzzer speaker
Buzzer sound switch
Volume of the sensor buzzer can be alternately switched to
LOW/LOUD/OFF by pressing the switch.
Auto shut off function
LS-70B/70C
The power will be turned off automatically if no laser beam
(Laser Sensor)
is detected for approximately 30 minutes. (To turn on the
laser sensor, press the power switch again.)
3
•Mark the position of On-Grade index.
(Top of the Laser Sensor is 40mm [1 9/16"]
from index for offset marking.)
Laser Sensor Holder
Clamp Knob
CAUTION
Label
LASER RADIATION
DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
C A U T I O N
LASER RADIATION
DO NOT STARE INTO BEAM
WAVE LENGTH 630-685nm
1mW MAXIMUM OUTPUT
DIODE LASER
CLASSII LASER PRODUCT

Advertisement

loading
Need help?

Need help?

Do you have a question about the RL-H3CL and is the answer not in the manual?

Questions and answers

Summary of Contents for Topcon RL-H3CL

  • Page 1: Safety Cautions

    For superior product performance, please read these instructions carefully and keep them in a convenient place for future ref- 1 RL-H3CL Instrument ......1set erence.
  • Page 2: Battery Replacement